Cargando…

Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012

BACKGROUND: Hip replacement and hip resurfacing are common surgical procedures with an estimated risk of revision of 4% over 10 year period. Approximately 58% of hip replacements will last 25 years. Some implants have higher revision rates and early identification of poorly performing hip replacemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Begun, Alexander, MacGregor, Alexander J., Pchejetski, Dmitri, Kulinskaya, Elena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7402470/
https://www.ncbi.nlm.nih.gov/pubmed/32750091
http://dx.doi.org/10.1371/journal.pone.0236701
_version_ 1783566762654040064
author Begun, Alexander
MacGregor, Alexander J.
Pchejetski, Dmitri
Kulinskaya, Elena
author_facet Begun, Alexander
MacGregor, Alexander J.
Pchejetski, Dmitri
Kulinskaya, Elena
author_sort Begun, Alexander
collection PubMed
description BACKGROUND: Hip replacement and hip resurfacing are common surgical procedures with an estimated risk of revision of 4% over 10 year period. Approximately 58% of hip replacements will last 25 years. Some implants have higher revision rates and early identification of poorly performing hip replacement implant brands and cup/head brand combinations is vital. AIMS: Development of a dynamic monitoring method for the revision rates of hip implants. METHODS: Data on the outcomes following the hip replacement surgery between 2004 and 2012 was obtained from the National Joint Register (NJR) in the UK. A novel dynamic algorithm based on the CUmulative SUM (CUSUM) methodology with adjustment for casemix and random frailty for an operating unit was developed and implemented to monitor the revision rates over time. The Benjamini-Hochberg FDR method was used to adjust for multiple testing of numerous hip replacement implant brands and cup/ head combinations at each time point. RESULTS: Three poorly performing cup brands and two cup/ head brand combinations have been detected. Wright Medical UK Ltd Conserve Plus Resurfacing Cup (cup o), DePuy ASR Resurfacing Cup (cup e), and Endo Plus (UK) Limited EP-Fit Plus Polyethylene cup (cup g) showed stable multiple alarms over the period of a year or longer. An addition of a random frailty term did not change the list of underperforming components. The model with added random effect was more conservative, showing less and more delayed alarms. CONCLUSIONS: Our new algorithm is an efficient method for early detection of poorly performing components in hip replacement surgery. It can also be used for similar tasks of dynamic quality monitoring in healthcare.
format Online
Article
Text
id pubmed-7402470
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-74024702020-08-12 Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012 Begun, Alexander MacGregor, Alexander J. Pchejetski, Dmitri Kulinskaya, Elena PLoS One Research Article BACKGROUND: Hip replacement and hip resurfacing are common surgical procedures with an estimated risk of revision of 4% over 10 year period. Approximately 58% of hip replacements will last 25 years. Some implants have higher revision rates and early identification of poorly performing hip replacement implant brands and cup/head brand combinations is vital. AIMS: Development of a dynamic monitoring method for the revision rates of hip implants. METHODS: Data on the outcomes following the hip replacement surgery between 2004 and 2012 was obtained from the National Joint Register (NJR) in the UK. A novel dynamic algorithm based on the CUmulative SUM (CUSUM) methodology with adjustment for casemix and random frailty for an operating unit was developed and implemented to monitor the revision rates over time. The Benjamini-Hochberg FDR method was used to adjust for multiple testing of numerous hip replacement implant brands and cup/ head combinations at each time point. RESULTS: Three poorly performing cup brands and two cup/ head brand combinations have been detected. Wright Medical UK Ltd Conserve Plus Resurfacing Cup (cup o), DePuy ASR Resurfacing Cup (cup e), and Endo Plus (UK) Limited EP-Fit Plus Polyethylene cup (cup g) showed stable multiple alarms over the period of a year or longer. An addition of a random frailty term did not change the list of underperforming components. The model with added random effect was more conservative, showing less and more delayed alarms. CONCLUSIONS: Our new algorithm is an efficient method for early detection of poorly performing components in hip replacement surgery. It can also be used for similar tasks of dynamic quality monitoring in healthcare. Public Library of Science 2020-08-04 /pmc/articles/PMC7402470/ /pubmed/32750091 http://dx.doi.org/10.1371/journal.pone.0236701 Text en © 2020 Begun et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Begun, Alexander
MacGregor, Alexander J.
Pchejetski, Dmitri
Kulinskaya, Elena
Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title_full Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title_fullStr Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title_full_unstemmed Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title_short Dynamic early identification of hip replacement implants with high revision rates. Study based on the NJR data from UK during 2004-2012
title_sort dynamic early identification of hip replacement implants with high revision rates. study based on the njr data from uk during 2004-2012
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7402470/
https://www.ncbi.nlm.nih.gov/pubmed/32750091
http://dx.doi.org/10.1371/journal.pone.0236701
work_keys_str_mv AT begunalexander dynamicearlyidentificationofhipreplacementimplantswithhighrevisionratesstudybasedonthenjrdatafromukduring20042012
AT macgregoralexanderj dynamicearlyidentificationofhipreplacementimplantswithhighrevisionratesstudybasedonthenjrdatafromukduring20042012
AT pchejetskidmitri dynamicearlyidentificationofhipreplacementimplantswithhighrevisionratesstudybasedonthenjrdatafromukduring20042012
AT kulinskayaelena dynamicearlyidentificationofhipreplacementimplantswithhighrevisionratesstudybasedonthenjrdatafromukduring20042012