Cargando…
Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method
Cholesterol efflux capacity (CEC) is an atheroprotective function of high-density lipoprotein (HDL). CEC is currently measured using artificially prepared foam cells composed of cultured macrophage and (3)H-cholesterol. However, this conventional method is not suitable for clinical laboratory use du...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Portland Press Ltd.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7403950/ https://www.ncbi.nlm.nih.gov/pubmed/32706025 http://dx.doi.org/10.1042/BSR20201495 |
_version_ | 1783567043387195392 |
---|---|
author | Horiuchi, Yuna Lai, Shao-Jui Kameda, Takahiro Tozuka, Minoru Ohkawa, Ryunosuke |
author_facet | Horiuchi, Yuna Lai, Shao-Jui Kameda, Takahiro Tozuka, Minoru Ohkawa, Ryunosuke |
author_sort | Horiuchi, Yuna |
collection | PubMed |
description | Cholesterol efflux capacity (CEC) is an atheroprotective function of high-density lipoprotein (HDL). CEC is currently measured using artificially prepared foam cells composed of cultured macrophage and (3)H-cholesterol. However, this conventional method is not suitable for clinical laboratory use due to poor repeatability, complexity, and low safety. Recently, we reported a novel CEC assay, called the immobilized liposome-bound gel beads (ILG) method. The ILG method is an alternative to foam cells, comprising gel beads and 4,4-diflioro-4-bora-3a,4a-s-indacene labeled cholesterol (BODIPY-cholesterol) instead of macrophage and (3)H-cholesterol, respectively. The ILG method has shown adequate basic properties and strong correlation with the conventional method. Here, we aimed to compare this new ILG method with the conventional method in-depth. When apoB-depleted serum was used as the cholesterol acceptor (CA), the ILG method had far better reproducibility than the conventional method. The CEC of major HDL subclasses HDL(2) and HDL(3) had similar results in both the ILG and conventional method. However, the ILG method did not reflect the CEC of apolipoprotein (apo) A–I and a minor HDL subclass which uses ATP-binding cassette transporter A1 on foam cells. Superior reproducibility of the ILG method, which is a limitation of the conventional method, and similar CEC results for major HDL subclasses in the ILG and conventional methods, provide further evidence that the ILG method is promising for measuring CEC clinically. However, some HDL subclasses or apo might have poor CEC correlation between these methods. Further research is therefore needed to confirm the clinical significance of estimating CEC by the ILG method. |
format | Online Article Text |
id | pubmed-7403950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Portland Press Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74039502020-08-12 Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method Horiuchi, Yuna Lai, Shao-Jui Kameda, Takahiro Tozuka, Minoru Ohkawa, Ryunosuke Biosci Rep Cardiovascular System & Vascular Biology Cholesterol efflux capacity (CEC) is an atheroprotective function of high-density lipoprotein (HDL). CEC is currently measured using artificially prepared foam cells composed of cultured macrophage and (3)H-cholesterol. However, this conventional method is not suitable for clinical laboratory use due to poor repeatability, complexity, and low safety. Recently, we reported a novel CEC assay, called the immobilized liposome-bound gel beads (ILG) method. The ILG method is an alternative to foam cells, comprising gel beads and 4,4-diflioro-4-bora-3a,4a-s-indacene labeled cholesterol (BODIPY-cholesterol) instead of macrophage and (3)H-cholesterol, respectively. The ILG method has shown adequate basic properties and strong correlation with the conventional method. Here, we aimed to compare this new ILG method with the conventional method in-depth. When apoB-depleted serum was used as the cholesterol acceptor (CA), the ILG method had far better reproducibility than the conventional method. The CEC of major HDL subclasses HDL(2) and HDL(3) had similar results in both the ILG and conventional method. However, the ILG method did not reflect the CEC of apolipoprotein (apo) A–I and a minor HDL subclass which uses ATP-binding cassette transporter A1 on foam cells. Superior reproducibility of the ILG method, which is a limitation of the conventional method, and similar CEC results for major HDL subclasses in the ILG and conventional methods, provide further evidence that the ILG method is promising for measuring CEC clinically. However, some HDL subclasses or apo might have poor CEC correlation between these methods. Further research is therefore needed to confirm the clinical significance of estimating CEC by the ILG method. Portland Press Ltd. 2020-08-04 /pmc/articles/PMC7403950/ /pubmed/32706025 http://dx.doi.org/10.1042/BSR20201495 Text en © 2020 The Author(s). https://creativecommons.org/licenses/by/4.0/ This is an open access article published by Portland Press Limited on behalf of the Biochemical Society and distributed under the Creative Commons Attribution License 4.0 (CC BY). |
spellingShingle | Cardiovascular System & Vascular Biology Horiuchi, Yuna Lai, Shao-Jui Kameda, Takahiro Tozuka, Minoru Ohkawa, Ryunosuke Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title | Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title_full | Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title_fullStr | Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title_full_unstemmed | Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title_short | Comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
title_sort | comparison of a novel cholesterol efflux assay using immobilized liposome-bound gel beads with the conventional method |
topic | Cardiovascular System & Vascular Biology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7403950/ https://www.ncbi.nlm.nih.gov/pubmed/32706025 http://dx.doi.org/10.1042/BSR20201495 |
work_keys_str_mv | AT horiuchiyuna comparisonofanovelcholesteroleffluxassayusingimmobilizedliposomeboundgelbeadswiththeconventionalmethod AT laishaojui comparisonofanovelcholesteroleffluxassayusingimmobilizedliposomeboundgelbeadswiththeconventionalmethod AT kamedatakahiro comparisonofanovelcholesteroleffluxassayusingimmobilizedliposomeboundgelbeadswiththeconventionalmethod AT tozukaminoru comparisonofanovelcholesteroleffluxassayusingimmobilizedliposomeboundgelbeadswiththeconventionalmethod AT ohkawaryunosuke comparisonofanovelcholesteroleffluxassayusingimmobilizedliposomeboundgelbeadswiththeconventionalmethod |