Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7404478/ https://www.ncbi.nlm.nih.gov/pubmed/32698464 http://dx.doi.org/10.3390/sports8070103 |
_version_ | 1783567145177710592 |
---|---|
author | Imbach, Frank Candau, Robin Chailan, Romain Perrey, Stephane |
author_facet | Imbach, Frank Candau, Robin Chailan, Romain Perrey, Stephane |
author_sort | Imbach, Frank |
collection | PubMed |
description | This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ([Formula: see text] , [Formula: see text]), and between Stryd PO and external mechanical power ([Formula: see text] , [Formula: see text]). Stryd power meter underestimated PO ([Formula: see text]) whereas GCT and LSS values did not show any significant differences with the reference measures ([Formula: see text] , [Formula: see text] , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO. |
format | Online Article Text |
id | pubmed-7404478 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74044782020-08-11 Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds Imbach, Frank Candau, Robin Chailan, Romain Perrey, Stephane Sports (Basel) Article This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ([Formula: see text] , [Formula: see text]), and between Stryd PO and external mechanical power ([Formula: see text] , [Formula: see text]). Stryd power meter underestimated PO ([Formula: see text]) whereas GCT and LSS values did not show any significant differences with the reference measures ([Formula: see text] , [Formula: see text] , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO. MDPI 2020-07-20 /pmc/articles/PMC7404478/ /pubmed/32698464 http://dx.doi.org/10.3390/sports8070103 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Imbach, Frank Candau, Robin Chailan, Romain Perrey, Stephane Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title | Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title_full | Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title_fullStr | Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title_full_unstemmed | Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title_short | Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds |
title_sort | validity of the stryd power meter in measuring running parameters at submaximal speeds |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7404478/ https://www.ncbi.nlm.nih.gov/pubmed/32698464 http://dx.doi.org/10.3390/sports8070103 |
work_keys_str_mv | AT imbachfrank validityofthestrydpowermeterinmeasuringrunningparametersatsubmaximalspeeds AT candaurobin validityofthestrydpowermeterinmeasuringrunningparametersatsubmaximalspeeds AT chailanromain validityofthestrydpowermeterinmeasuringrunningparametersatsubmaximalspeeds AT perreystephane validityofthestrydpowermeterinmeasuringrunningparametersatsubmaximalspeeds |