A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells
Numerous in vitro studies have been conducted in conventional static cell culture systems. However, most of the results represent an average response from a population of cells regardless of their local microenvironment. A microfluidic probe is a non-contact technology that has been widely used to p...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7408473/ https://www.ncbi.nlm.nih.gov/pubmed/32708814 http://dx.doi.org/10.3390/mi11070691 |
_version_ | 1783567839784861696 |
---|---|
author | Shinha, Kenta Nihei, Wataru Kimura, Hiroshi |
author_facet | Shinha, Kenta Nihei, Wataru Kimura, Hiroshi |
author_sort | Shinha, Kenta |
collection | PubMed |
description | Numerous in vitro studies have been conducted in conventional static cell culture systems. However, most of the results represent an average response from a population of cells regardless of their local microenvironment. A microfluidic probe is a non-contact technology that has been widely used to perform local chemical stimulation within a restricted space, providing elaborated modulation and analysis of cellular responses within the microenvironment. Although microfluidic probes developed earlier have various potential applications, the two-dimensional structure can compromise their functionality and flexibility for practical use. In this study, we developed a three-dimensional microfluidic probe integrated device equipped with vertically oriented microchannels to overcome crucial challenges and tested the potential utility of the device in biological research. We demonstrated that the device tightly regulated spatial diffusion of a fluorescent molecule, and the flow profile predicted by simulation replicated the experimental results. Additionally, the device modulated the physiological Ca(2+) response of cells within the restricted area by altering the local and temporal concentrations of biomolecules such as ATP. The novel device developed in this study may provide various applications for biological studies and contribute to further understanding of molecular mechanisms underlying cellular physiology. |
format | Online Article Text |
id | pubmed-7408473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74084732020-08-13 A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells Shinha, Kenta Nihei, Wataru Kimura, Hiroshi Micromachines (Basel) Article Numerous in vitro studies have been conducted in conventional static cell culture systems. However, most of the results represent an average response from a population of cells regardless of their local microenvironment. A microfluidic probe is a non-contact technology that has been widely used to perform local chemical stimulation within a restricted space, providing elaborated modulation and analysis of cellular responses within the microenvironment. Although microfluidic probes developed earlier have various potential applications, the two-dimensional structure can compromise their functionality and flexibility for practical use. In this study, we developed a three-dimensional microfluidic probe integrated device equipped with vertically oriented microchannels to overcome crucial challenges and tested the potential utility of the device in biological research. We demonstrated that the device tightly regulated spatial diffusion of a fluorescent molecule, and the flow profile predicted by simulation replicated the experimental results. Additionally, the device modulated the physiological Ca(2+) response of cells within the restricted area by altering the local and temporal concentrations of biomolecules such as ATP. The novel device developed in this study may provide various applications for biological studies and contribute to further understanding of molecular mechanisms underlying cellular physiology. MDPI 2020-07-16 /pmc/articles/PMC7408473/ /pubmed/32708814 http://dx.doi.org/10.3390/mi11070691 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shinha, Kenta Nihei, Wataru Kimura, Hiroshi A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title | A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title_full | A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title_fullStr | A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title_full_unstemmed | A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title_short | A Microfluidic Probe Integrated Device for Spatiotemporal 3D Chemical Stimulation in Cells |
title_sort | microfluidic probe integrated device for spatiotemporal 3d chemical stimulation in cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7408473/ https://www.ncbi.nlm.nih.gov/pubmed/32708814 http://dx.doi.org/10.3390/mi11070691 |
work_keys_str_mv | AT shinhakenta amicrofluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells AT niheiwataru amicrofluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells AT kimurahiroshi amicrofluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells AT shinhakenta microfluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells AT niheiwataru microfluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells AT kimurahiroshi microfluidicprobeintegrateddeviceforspatiotemporal3dchemicalstimulationincells |