Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study

BACKGROUND: One of the most recent innovations in bone augmentation surgery is represented by computer-aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study w...

Descripción completa

Detalles Bibliográficos
Autores principales: Cucchi, Alessandro, Bianchi, Alessandro, Calamai, Paolo, Rinaldi, Lisa, Mangano, Francesco, Vignudelli, Elisabetta, Corinaldesi, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7409710/
https://www.ncbi.nlm.nih.gov/pubmed/32758217
http://dx.doi.org/10.1186/s12903-020-01205-4
_version_ 1783568114855706624
author Cucchi, Alessandro
Bianchi, Alessandro
Calamai, Paolo
Rinaldi, Lisa
Mangano, Francesco
Vignudelli, Elisabetta
Corinaldesi, Giuseppe
author_facet Cucchi, Alessandro
Bianchi, Alessandro
Calamai, Paolo
Rinaldi, Lisa
Mangano, Francesco
Vignudelli, Elisabetta
Corinaldesi, Giuseppe
author_sort Cucchi, Alessandro
collection PubMed
description BACKGROUND: One of the most recent innovations in bone augmentation surgery is represented by computer-aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study was to evaluate the effectiveness/reliability of this technique in a consecutive series of cases. METHODS: Ten patients in need of bone augmentation before implant therapy were treated using CAD/CAM customized titanium meshes. A digital workflow was adopted to design virtual meshes on 3D bone models. Then, Direct Metal Laser Sintering (DMLS) technology was used to produce the titanium meshes, and vertical ridge augmentation was performed according to an established surgical protocol. Surgical complications, healing complications, vertical bone gain (VBG), planned bone volume (PBV), lacking bone volume (LBV), regenerated bone volume (RBV), average regeneration rate (RR) and implant success rate were evaluated. RESULTS: All augmented sites were successfully restored with definitive implant-supported fixed partial dentures. Measurements showed an average VBG of 4.5 ± 1.8 mm at surgical re-entry. Surgical and healing complications occurred in 30% and 10% of cases, respectively. Mean values of PBV, LBV, and RBV were 984, 92, and 892 mm(3), respectively. The average RR achieved was 89%. All 26 implants were successfully in function after 1 year of follow-up. CONCLUSIONS: The results of this study suggest that the bone augmentation by means of DMLS custom-made titanium meshes can be considered a reliable and effective technique in restoring vertical bone defects.
format Online
Article
Text
id pubmed-7409710
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-74097102020-08-10 Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study Cucchi, Alessandro Bianchi, Alessandro Calamai, Paolo Rinaldi, Lisa Mangano, Francesco Vignudelli, Elisabetta Corinaldesi, Giuseppe BMC Oral Health Research Article BACKGROUND: One of the most recent innovations in bone augmentation surgery is represented by computer-aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study was to evaluate the effectiveness/reliability of this technique in a consecutive series of cases. METHODS: Ten patients in need of bone augmentation before implant therapy were treated using CAD/CAM customized titanium meshes. A digital workflow was adopted to design virtual meshes on 3D bone models. Then, Direct Metal Laser Sintering (DMLS) technology was used to produce the titanium meshes, and vertical ridge augmentation was performed according to an established surgical protocol. Surgical complications, healing complications, vertical bone gain (VBG), planned bone volume (PBV), lacking bone volume (LBV), regenerated bone volume (RBV), average regeneration rate (RR) and implant success rate were evaluated. RESULTS: All augmented sites were successfully restored with definitive implant-supported fixed partial dentures. Measurements showed an average VBG of 4.5 ± 1.8 mm at surgical re-entry. Surgical and healing complications occurred in 30% and 10% of cases, respectively. Mean values of PBV, LBV, and RBV were 984, 92, and 892 mm(3), respectively. The average RR achieved was 89%. All 26 implants were successfully in function after 1 year of follow-up. CONCLUSIONS: The results of this study suggest that the bone augmentation by means of DMLS custom-made titanium meshes can be considered a reliable and effective technique in restoring vertical bone defects. BioMed Central 2020-08-05 /pmc/articles/PMC7409710/ /pubmed/32758217 http://dx.doi.org/10.1186/s12903-020-01205-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Cucchi, Alessandro
Bianchi, Alessandro
Calamai, Paolo
Rinaldi, Lisa
Mangano, Francesco
Vignudelli, Elisabetta
Corinaldesi, Giuseppe
Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title_full Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title_fullStr Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title_full_unstemmed Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title_short Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
title_sort clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (cad/cam) customized titanium meshes: a pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7409710/
https://www.ncbi.nlm.nih.gov/pubmed/32758217
http://dx.doi.org/10.1186/s12903-020-01205-4
work_keys_str_mv AT cucchialessandro clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT bianchialessandro clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT calamaipaolo clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT rinaldilisa clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT manganofrancesco clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT vignudellielisabetta clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy
AT corinaldesigiuseppe clinicalandvolumetricoutcomesafterverticalridgeaugmentationusingcomputeraideddesigncomputeraidedmanufacturingcadcamcustomizedtitaniummeshesapilotstudy