Real-world outcomes comparison among adults with atrial fibrillation undergoing catheter ablation with a contact force porous tip catheter versus a second-generation cryoballoon catheter: a retrospective analysis of multihospital US database
OBJECTIVE: To compare real-world clinical and economic outcomes among atrial fibrillation (AF) patients undergoing cardiac ablation with the contact force-sensing porous tip THERMOCOOL SMARTTOUCH SF (STSF) catheter versus the Arctic Front Advance Cryoballoon (AFA-CB) catheter. DESIGN: Retrospective,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7409957/ https://www.ncbi.nlm.nih.gov/pubmed/32759243 http://dx.doi.org/10.1136/bmjopen-2019-035499 |
Sumario: | OBJECTIVE: To compare real-world clinical and economic outcomes among atrial fibrillation (AF) patients undergoing cardiac ablation with the contact force-sensing porous tip THERMOCOOL SMARTTOUCH SF (STSF) catheter versus the Arctic Front Advance Cryoballoon (AFA-CB) catheter. DESIGN: Retrospective, observational cohort study. SETTING: Premier Healthcare Database (PHD), between 1 September 2016 and 30 June 2018. PARTICIPANTS: Patients with AF (≥18 years) were included if they had an index ablation procedure performed using the STSF catheter or AFA-CB catheter at a US hospital that consistently provided inpatient and outpatient data to PHD in the 12-month preindex period. Using 1:1 propensity score matching, patient groups were matched on study covariates. PRIMARY AND SECONDARY OUTCOME MEASURES: Cost, length of stay (LOS), readmissions, direct current cardioversion (DCCV) and reablation outcomes were compared between matched cohorts of STSF and AFA-CB patients. RESULTS: A total of 3015 patients with AF met the study criteria, of which 1720 had ablation using the STSF catheter and 1295 had ablation using the AFA-CB catheter. In the propensity-matched sample, patients receiving ablation with the STSF catheter had ~17% lower total costs (US$23 096 vs US$27 682, p≤0.0001) and ~27% lower supply costs (US$10 208 vs US$13 816, p≤0.0001) versus patients receiving ablation with the AFA-CB catheter. A significantly lower likelihood of 4-month to 6-month cardiovascular-related readmission (OR 0.460, 95% CI 0.220 to 0.959) was associated with the STSF catheter versus the AFA-CB catheter. No significant differences in LOS, room and board cost, 4-month to 6-month all-cause and AF-related readmissions, DCCV and reablation were observed among technologies. Sensitivity analysis restricting patient sample by provider ablation volume demonstrated similar results. CONCLUSION: Lower index ablation total and supply costs were observed among patients with AF undergoing cardiac catheter ablation using the STSF catheter versus the AFA-CB catheter. |
---|