Cargando…
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7412083/ https://www.ncbi.nlm.nih.gov/pubmed/32664202 http://dx.doi.org/10.3390/s20143847 |
_version_ | 1783568526424932352 |
---|---|
author | Dabrowska, Sylwia Ekiert, Martyna Wojcik, Kaja Kalemba, Marek Mlyniec, Andrzej |
author_facet | Dabrowska, Sylwia Ekiert, Martyna Wojcik, Kaja Kalemba, Marek Mlyniec, Andrzej |
author_sort | Dabrowska, Sylwia |
collection | PubMed |
description | In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models. |
format | Online Article Text |
id | pubmed-7412083 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74120832020-08-25 A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles Dabrowska, Sylwia Ekiert, Martyna Wojcik, Kaja Kalemba, Marek Mlyniec, Andrzej Sensors (Basel) Article In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models. MDPI 2020-07-10 /pmc/articles/PMC7412083/ /pubmed/32664202 http://dx.doi.org/10.3390/s20143847 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dabrowska, Sylwia Ekiert, Martyna Wojcik, Kaja Kalemba, Marek Mlyniec, Andrzej A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title | A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_full | A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_fullStr | A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_full_unstemmed | A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_short | A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles |
title_sort | 3d scanning system for inverse analysis of moist biological samples: design and validation using tendon fascicle bundles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7412083/ https://www.ncbi.nlm.nih.gov/pubmed/32664202 http://dx.doi.org/10.3390/s20143847 |
work_keys_str_mv | AT dabrowskasylwia a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT ekiertmartyna a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT wojcikkaja a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT kalembamarek a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT mlyniecandrzej a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT dabrowskasylwia 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT ekiertmartyna 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT wojcikkaja 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT kalembamarek 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles AT mlyniecandrzej 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles |