Cargando…

A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles

In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system...

Descripción completa

Detalles Bibliográficos
Autores principales: Dabrowska, Sylwia, Ekiert, Martyna, Wojcik, Kaja, Kalemba, Marek, Mlyniec, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7412083/
https://www.ncbi.nlm.nih.gov/pubmed/32664202
http://dx.doi.org/10.3390/s20143847
_version_ 1783568526424932352
author Dabrowska, Sylwia
Ekiert, Martyna
Wojcik, Kaja
Kalemba, Marek
Mlyniec, Andrzej
author_facet Dabrowska, Sylwia
Ekiert, Martyna
Wojcik, Kaja
Kalemba, Marek
Mlyniec, Andrzej
author_sort Dabrowska, Sylwia
collection PubMed
description In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models.
format Online
Article
Text
id pubmed-7412083
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74120832020-08-25 A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles Dabrowska, Sylwia Ekiert, Martyna Wojcik, Kaja Kalemba, Marek Mlyniec, Andrzej Sensors (Basel) Article In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models. MDPI 2020-07-10 /pmc/articles/PMC7412083/ /pubmed/32664202 http://dx.doi.org/10.3390/s20143847 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dabrowska, Sylwia
Ekiert, Martyna
Wojcik, Kaja
Kalemba, Marek
Mlyniec, Andrzej
A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title_full A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title_fullStr A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title_full_unstemmed A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title_short A 3D Scanning System for Inverse Analysis of Moist Biological Samples: Design and Validation Using Tendon Fascicle Bundles
title_sort 3d scanning system for inverse analysis of moist biological samples: design and validation using tendon fascicle bundles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7412083/
https://www.ncbi.nlm.nih.gov/pubmed/32664202
http://dx.doi.org/10.3390/s20143847
work_keys_str_mv AT dabrowskasylwia a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT ekiertmartyna a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT wojcikkaja a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT kalembamarek a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT mlyniecandrzej a3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT dabrowskasylwia 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT ekiertmartyna 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT wojcikkaja 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT kalembamarek 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles
AT mlyniecandrzej 3dscanningsystemforinverseanalysisofmoistbiologicalsamplesdesignandvalidationusingtendonfasciclebundles