Cargando…

Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players

The aim of the study was to assess the validity and reliability of wearable body metric Hexoskin “smart shirt” in measuring heart rate (HR) at pre-exercise and during peak effort in a field test incorporating vigorous movements of the upper body. Measurements were recorded simultaneously using the H...

Descripción completa

Detalles Bibliográficos
Autores principales: Haddad, Monoem, Hermassi, Souhail, Aganovic, Zlatan, Dalansi, Feriel, Kharbach, Mariam, Mohamed, Azam Omar, Bibi, Khalid W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413063/
https://www.ncbi.nlm.nih.gov/pubmed/32848879
http://dx.doi.org/10.3389/fphys.2020.00957
_version_ 1783568731497037824
author Haddad, Monoem
Hermassi, Souhail
Aganovic, Zlatan
Dalansi, Feriel
Kharbach, Mariam
Mohamed, Azam Omar
Bibi, Khalid W.
author_facet Haddad, Monoem
Hermassi, Souhail
Aganovic, Zlatan
Dalansi, Feriel
Kharbach, Mariam
Mohamed, Azam Omar
Bibi, Khalid W.
author_sort Haddad, Monoem
collection PubMed
description The aim of the study was to assess the validity and reliability of wearable body metric Hexoskin “smart shirt” in measuring heart rate (HR) at pre-exercise and during peak effort in a field test incorporating vigorous movements of the upper body. Measurements were recorded simultaneously using the Hexoskin and Polar Team Pro. Nine male professional handball players (age: 21.8 ± 2.4 years; weight: 83 ± 10.26 kg; height: 1.81 ± 0.09 m; and BMI: 25.17 ± 2.23) volitionally participated in the study by completing two 400 m shuttle run test trials (10 shuttles), each separated by a 48 to 72 h recovery period. Results indicated significant correlations between Hexoskin and Polar Team Pro system in pre-exercise HR. Hexoskin provided erroneous measurements in four of the nine athletes during peak effort. Subsequent correction yielded no consistency between the Polar Team Pro system and Hexoskin between the first and the second trial. Hexoskin showed significant reliability in pre-exercise HR. However, Hexoskin picked up excessive artifact during vigorous physical activity in four of the nine athletes rendering the results in these cases useless. Nevertheless, in athletes where artifact was not an issue, ICC yielded a good estimate. The main findings indicate that Hexoskin has good validity and reliability in measuring pre-exercise HR in handball players and hence may be used with high confidence in slow motion activities. However, vigorous physical activity with jarring multidirectional upper body movements posed a challenge for Hexoskin.
format Online
Article
Text
id pubmed-7413063
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-74130632020-08-25 Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players Haddad, Monoem Hermassi, Souhail Aganovic, Zlatan Dalansi, Feriel Kharbach, Mariam Mohamed, Azam Omar Bibi, Khalid W. Front Physiol Physiology The aim of the study was to assess the validity and reliability of wearable body metric Hexoskin “smart shirt” in measuring heart rate (HR) at pre-exercise and during peak effort in a field test incorporating vigorous movements of the upper body. Measurements were recorded simultaneously using the Hexoskin and Polar Team Pro. Nine male professional handball players (age: 21.8 ± 2.4 years; weight: 83 ± 10.26 kg; height: 1.81 ± 0.09 m; and BMI: 25.17 ± 2.23) volitionally participated in the study by completing two 400 m shuttle run test trials (10 shuttles), each separated by a 48 to 72 h recovery period. Results indicated significant correlations between Hexoskin and Polar Team Pro system in pre-exercise HR. Hexoskin provided erroneous measurements in four of the nine athletes during peak effort. Subsequent correction yielded no consistency between the Polar Team Pro system and Hexoskin between the first and the second trial. Hexoskin showed significant reliability in pre-exercise HR. However, Hexoskin picked up excessive artifact during vigorous physical activity in four of the nine athletes rendering the results in these cases useless. Nevertheless, in athletes where artifact was not an issue, ICC yielded a good estimate. The main findings indicate that Hexoskin has good validity and reliability in measuring pre-exercise HR in handball players and hence may be used with high confidence in slow motion activities. However, vigorous physical activity with jarring multidirectional upper body movements posed a challenge for Hexoskin. Frontiers Media S.A. 2020-07-31 /pmc/articles/PMC7413063/ /pubmed/32848879 http://dx.doi.org/10.3389/fphys.2020.00957 Text en Copyright © 2020 Haddad, Hermassi, Aganovic, Dalansi, Kharbach, Mohamed and Bibi. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Haddad, Monoem
Hermassi, Souhail
Aganovic, Zlatan
Dalansi, Feriel
Kharbach, Mariam
Mohamed, Azam Omar
Bibi, Khalid W.
Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title_full Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title_fullStr Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title_full_unstemmed Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title_short Ecological Validation and Reliability of Hexoskin Wearable Body Metrics Tool in Measuring Pre-exercise and Peak Heart Rate During Shuttle Run Test in Professional Handball Players
title_sort ecological validation and reliability of hexoskin wearable body metrics tool in measuring pre-exercise and peak heart rate during shuttle run test in professional handball players
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413063/
https://www.ncbi.nlm.nih.gov/pubmed/32848879
http://dx.doi.org/10.3389/fphys.2020.00957
work_keys_str_mv AT haddadmonoem ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT hermassisouhail ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT aganoviczlatan ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT dalansiferiel ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT kharbachmariam ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT mohamedazamomar ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers
AT bibikhalidw ecologicalvalidationandreliabilityofhexoskinwearablebodymetricstoolinmeasuringpreexerciseandpeakheartrateduringshuttleruntestinprofessionalhandballplayers