Cargando…

Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?

BACKGROUND AND AIMS: Non-invasive blood pressure (NiBP) varies with the arm and body position. In the lateral decubitus position (LDP), the non-dependent arm reads lower, and the dependent arm reads higher pressure. We aimed to study the correlation between the NiBP and invasive arterial blood press...

Descripción completa

Detalles Bibliográficos
Autores principales: Thomas, Anju S, Moorthy, Ranjith K, Raju, Krishnaprabhu, Lakshmanan, Jeyaseelan, Joy, Melvin, Mariappan, Ramamani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413357/
https://www.ncbi.nlm.nih.gov/pubmed/32792741
http://dx.doi.org/10.4103/ija.IJA_125_20
_version_ 1783568778105192448
author Thomas, Anju S
Moorthy, Ranjith K
Raju, Krishnaprabhu
Lakshmanan, Jeyaseelan
Joy, Melvin
Mariappan, Ramamani
author_facet Thomas, Anju S
Moorthy, Ranjith K
Raju, Krishnaprabhu
Lakshmanan, Jeyaseelan
Joy, Melvin
Mariappan, Ramamani
author_sort Thomas, Anju S
collection PubMed
description BACKGROUND AND AIMS: Non-invasive blood pressure (NiBP) varies with the arm and body position. In the lateral decubitus position (LDP), the non-dependent arm reads lower, and the dependent arm reads higher pressure. We aimed to study the correlation between the NiBP and invasive arterial blood pressure (ABP) as anaesthesia progressed and its correlation in different BP ranges. METHODS: American Society of Anesthesiologists (ASA I–III) patients, between 18–70 years undergoing neurosurgical procedures in the LDP were studied. All were anaesthetised using a standard protocol, positioned in the LDP. NiBP was measured every 15 min in both dependent and non-dependent arms and correlated with the ABP. RESULTS: Intra-class correlation (ICC) done between the dependent arm NiBP and ABP showed good correlation for mean and systolic BP and moderate correlation for diastolic BP. ICC was 0.800, 0.846 and 0.818 for mean and 0.771, 0.782, 0.792 for systolic BP at 15 min, 1 h, and 2 h, respectively. The ICC between the non-dependent arm NiBP and the invasive ABP showed poor correlation for all BP (systolic, diastolic and mean). As anaesthesia progressed, the mean difference between the NiBP and the ABP decreased in the dependent arm and increased in the non-dependent arm. The strength of agreement between the NiBP and the ABP in various BP ranges showed moderate correlation for the dependent arm NiBP (0.45–0.54) and poor correlation (0.21–0.38) for the non-dependent arm. CONCLUSION: The NiBP of the dependent arm correlated well with ABP in LDP under general anaesthesia (GA). It is better to defer measuring NiBP in the non-dependent arm as the correlation with ABP is poor.
format Online
Article
Text
id pubmed-7413357
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-74133572020-08-12 Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm? Thomas, Anju S Moorthy, Ranjith K Raju, Krishnaprabhu Lakshmanan, Jeyaseelan Joy, Melvin Mariappan, Ramamani Indian J Anaesth Original Article BACKGROUND AND AIMS: Non-invasive blood pressure (NiBP) varies with the arm and body position. In the lateral decubitus position (LDP), the non-dependent arm reads lower, and the dependent arm reads higher pressure. We aimed to study the correlation between the NiBP and invasive arterial blood pressure (ABP) as anaesthesia progressed and its correlation in different BP ranges. METHODS: American Society of Anesthesiologists (ASA I–III) patients, between 18–70 years undergoing neurosurgical procedures in the LDP were studied. All were anaesthetised using a standard protocol, positioned in the LDP. NiBP was measured every 15 min in both dependent and non-dependent arms and correlated with the ABP. RESULTS: Intra-class correlation (ICC) done between the dependent arm NiBP and ABP showed good correlation for mean and systolic BP and moderate correlation for diastolic BP. ICC was 0.800, 0.846 and 0.818 for mean and 0.771, 0.782, 0.792 for systolic BP at 15 min, 1 h, and 2 h, respectively. The ICC between the non-dependent arm NiBP and the invasive ABP showed poor correlation for all BP (systolic, diastolic and mean). As anaesthesia progressed, the mean difference between the NiBP and the ABP decreased in the dependent arm and increased in the non-dependent arm. The strength of agreement between the NiBP and the ABP in various BP ranges showed moderate correlation for the dependent arm NiBP (0.45–0.54) and poor correlation (0.21–0.38) for the non-dependent arm. CONCLUSION: The NiBP of the dependent arm correlated well with ABP in LDP under general anaesthesia (GA). It is better to defer measuring NiBP in the non-dependent arm as the correlation with ABP is poor. Wolters Kluwer - Medknow 2020-07 2020-07-01 /pmc/articles/PMC7413357/ /pubmed/32792741 http://dx.doi.org/10.4103/ija.IJA_125_20 Text en Copyright: © 2020 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Thomas, Anju S
Moorthy, Ranjith K
Raju, Krishnaprabhu
Lakshmanan, Jeyaseelan
Joy, Melvin
Mariappan, Ramamani
Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title_full Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title_fullStr Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title_full_unstemmed Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title_short Measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — Which arm gives more accurate BP in relation to invasive BP - dependent or non-dependent arm?
title_sort measurement of non-invasive blood pressure in lateral decubitus position under general anaesthesia — which arm gives more accurate bp in relation to invasive bp - dependent or non-dependent arm?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413357/
https://www.ncbi.nlm.nih.gov/pubmed/32792741
http://dx.doi.org/10.4103/ija.IJA_125_20
work_keys_str_mv AT thomasanjus measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm
AT moorthyranjithk measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm
AT rajukrishnaprabhu measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm
AT lakshmananjeyaseelan measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm
AT joymelvin measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm
AT mariappanramamani measurementofnoninvasivebloodpressureinlateraldecubituspositionundergeneralanaesthesiawhicharmgivesmoreaccuratebpinrelationtoinvasivebpdependentornondependentarm