Cargando…

Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida

We present a bleeding, infected (mycotic) pseudoaneurysm from the organism Pasteurella multocida. The patient presented septic from an infected total hip arthroplasty and was treated with surgical debridement, component retention, and antibiotics. She re-presented with hip pain and a marked hemoglob...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Cory D., Sridhar, Michael S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413924/
https://www.ncbi.nlm.nih.gov/pubmed/32793788
http://dx.doi.org/10.1016/j.artd.2020.06.014
_version_ 1783568890702331904
author Smith, Cory D.
Sridhar, Michael S.
author_facet Smith, Cory D.
Sridhar, Michael S.
author_sort Smith, Cory D.
collection PubMed
description We present a bleeding, infected (mycotic) pseudoaneurysm from the organism Pasteurella multocida. The patient presented septic from an infected total hip arthroplasty and was treated with surgical debridement, component retention, and antibiotics. She re-presented with hip pain and a marked hemoglobin decrease. Vascular studies revealed a pseudoaneurysm of the external iliac artery and large hematoma secondary to contiguous spread of her hip infection. The pseudoaneurysm was treated with an endovascular stent before further debridement surgery to avoid exsanguinating hemorrhage with surgical release of her tamponade. This case demonstrates the utmost importance of recognizing and treating vascular pathology in a patient with an infected prosthetic hip, large hematoma, and decreased hemoglobin.
format Online
Article
Text
id pubmed-7413924
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74139242020-08-12 Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida Smith, Cory D. Sridhar, Michael S. Arthroplast Today Case Report We present a bleeding, infected (mycotic) pseudoaneurysm from the organism Pasteurella multocida. The patient presented septic from an infected total hip arthroplasty and was treated with surgical debridement, component retention, and antibiotics. She re-presented with hip pain and a marked hemoglobin decrease. Vascular studies revealed a pseudoaneurysm of the external iliac artery and large hematoma secondary to contiguous spread of her hip infection. The pseudoaneurysm was treated with an endovascular stent before further debridement surgery to avoid exsanguinating hemorrhage with surgical release of her tamponade. This case demonstrates the utmost importance of recognizing and treating vascular pathology in a patient with an infected prosthetic hip, large hematoma, and decreased hemoglobin. Elsevier 2020-08-05 /pmc/articles/PMC7413924/ /pubmed/32793788 http://dx.doi.org/10.1016/j.artd.2020.06.014 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Smith, Cory D.
Sridhar, Michael S.
Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title_full Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title_fullStr Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title_full_unstemmed Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title_short Life-Threatening, Bleeding Pseudoaneurysm of the External Iliac Artery in the Setting of an Infected Total Hip Arthroplasty from Pasteurella multocida
title_sort life-threatening, bleeding pseudoaneurysm of the external iliac artery in the setting of an infected total hip arthroplasty from pasteurella multocida
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7413924/
https://www.ncbi.nlm.nih.gov/pubmed/32793788
http://dx.doi.org/10.1016/j.artd.2020.06.014
work_keys_str_mv AT smithcoryd lifethreateningbleedingpseudoaneurysmoftheexternaliliacarteryinthesettingofaninfectedtotalhiparthroplastyfrompasteurellamultocida
AT sridharmichaels lifethreateningbleedingpseudoaneurysmoftheexternaliliacarteryinthesettingofaninfectedtotalhiparthroplastyfrompasteurellamultocida