Cargando…

Comparison of Rates of Progression of Macular OCT Measures in Glaucoma

PURPOSE: The purpose of this study was to compare rates of change of various macular thickness measures and evaluate the influence of baseline damage on macular rates of change. METHODS: One hundred twelve eyes (112 patients) with ≥ 2 years of follow-up and ≥ 5 macular optical coherence tomography (...

Descripción completa

Detalles Bibliográficos
Autores principales: Rabiolo, Alessandro, Mohammadzadeh, Vahid, Fatehi, Nima, Morales, Esteban, Coleman, Anne L., Law, Simon K., Caprioli, Joseph, Nouri-Mahdavi, Kouros
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7414740/
https://www.ncbi.nlm.nih.gov/pubmed/32832255
http://dx.doi.org/10.1167/tvst.9.7.50
_version_ 1783569031145455616
author Rabiolo, Alessandro
Mohammadzadeh, Vahid
Fatehi, Nima
Morales, Esteban
Coleman, Anne L.
Law, Simon K.
Caprioli, Joseph
Nouri-Mahdavi, Kouros
author_facet Rabiolo, Alessandro
Mohammadzadeh, Vahid
Fatehi, Nima
Morales, Esteban
Coleman, Anne L.
Law, Simon K.
Caprioli, Joseph
Nouri-Mahdavi, Kouros
author_sort Rabiolo, Alessandro
collection PubMed
description PURPOSE: The purpose of this study was to compare rates of change of various macular thickness measures and evaluate the influence of baseline damage on macular rates of change. METHODS: One hundred twelve eyes (112 patients) with ≥ 2 years of follow-up and ≥ 5 macular optical coherence tomography (OCT) images and 10-2 visual field (VF) tests were included. OCT measures of interests were full macular thickness (FMT), ganglion cell complex (GCC), ganglion cell/inner plexiform layer (GCIPL), ganglion cell layer (GCL), and outer retinal layer (ORL) thickness in 3° × 3° superpixels. Rates of change were estimated with linear regression and normalized by dividing rates by the average normative superpixel thickness. We compared rates of change and proportion of significantly worsening superpixels (detection rate) and improving superpixels (false discovery rate [FDR]) among macular measures as a function of baseline thickness and 10-2 VF status. RESULTS: Median (interquartile range [IQR]) baseline VF mean deviation, follow-up time, and number of VFs/OCTs were −7.6 dB (−11.8 to −3.8 dB), 4.5 years (4.0–5.0 years), and 9 (8–10), respectively. Normalized FMT and GCC rates of change were faster and detection rates were higher than GCIPL and GCL (P < 0.001), but FMT had lower FDR than GCC (P = 0.02); faster FMT rates were partially explained by ORL rates of change. GCC detection rates were less likely than GCIPL and GCL rates to decrease with diminishing baseline thickness or worse VF damage. In eyes with 10-2 VF worsening, GCC and GCL demonstrated the fastest rates of change. CONCLUSIONS: GCC measurements are most likely to detect structural worsening along the spectrum of glaucoma severity. Although FMT rates of change are least influenced by baseline thickness, they partially reflect likely age-related ORL changes. TRANSLATIONAL RELEVANCE: GCC thickness measurements seem to be the optimal macular outcome measure for detection of glaucoma deterioration.
format Online
Article
Text
id pubmed-7414740
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-74147402020-08-21 Comparison of Rates of Progression of Macular OCT Measures in Glaucoma Rabiolo, Alessandro Mohammadzadeh, Vahid Fatehi, Nima Morales, Esteban Coleman, Anne L. Law, Simon K. Caprioli, Joseph Nouri-Mahdavi, Kouros Transl Vis Sci Technol Article PURPOSE: The purpose of this study was to compare rates of change of various macular thickness measures and evaluate the influence of baseline damage on macular rates of change. METHODS: One hundred twelve eyes (112 patients) with ≥ 2 years of follow-up and ≥ 5 macular optical coherence tomography (OCT) images and 10-2 visual field (VF) tests were included. OCT measures of interests were full macular thickness (FMT), ganglion cell complex (GCC), ganglion cell/inner plexiform layer (GCIPL), ganglion cell layer (GCL), and outer retinal layer (ORL) thickness in 3° × 3° superpixels. Rates of change were estimated with linear regression and normalized by dividing rates by the average normative superpixel thickness. We compared rates of change and proportion of significantly worsening superpixels (detection rate) and improving superpixels (false discovery rate [FDR]) among macular measures as a function of baseline thickness and 10-2 VF status. RESULTS: Median (interquartile range [IQR]) baseline VF mean deviation, follow-up time, and number of VFs/OCTs were −7.6 dB (−11.8 to −3.8 dB), 4.5 years (4.0–5.0 years), and 9 (8–10), respectively. Normalized FMT and GCC rates of change were faster and detection rates were higher than GCIPL and GCL (P < 0.001), but FMT had lower FDR than GCC (P = 0.02); faster FMT rates were partially explained by ORL rates of change. GCC detection rates were less likely than GCIPL and GCL rates to decrease with diminishing baseline thickness or worse VF damage. In eyes with 10-2 VF worsening, GCC and GCL demonstrated the fastest rates of change. CONCLUSIONS: GCC measurements are most likely to detect structural worsening along the spectrum of glaucoma severity. Although FMT rates of change are least influenced by baseline thickness, they partially reflect likely age-related ORL changes. TRANSLATIONAL RELEVANCE: GCC thickness measurements seem to be the optimal macular outcome measure for detection of glaucoma deterioration. The Association for Research in Vision and Ophthalmology 2020-06-30 /pmc/articles/PMC7414740/ /pubmed/32832255 http://dx.doi.org/10.1167/tvst.9.7.50 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Rabiolo, Alessandro
Mohammadzadeh, Vahid
Fatehi, Nima
Morales, Esteban
Coleman, Anne L.
Law, Simon K.
Caprioli, Joseph
Nouri-Mahdavi, Kouros
Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title_full Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title_fullStr Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title_full_unstemmed Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title_short Comparison of Rates of Progression of Macular OCT Measures in Glaucoma
title_sort comparison of rates of progression of macular oct measures in glaucoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7414740/
https://www.ncbi.nlm.nih.gov/pubmed/32832255
http://dx.doi.org/10.1167/tvst.9.7.50
work_keys_str_mv AT rabioloalessandro comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT mohammadzadehvahid comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT fatehinima comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT moralesesteban comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT colemanannel comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT lawsimonk comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT capriolijoseph comparisonofratesofprogressionofmacularoctmeasuresinglaucoma
AT nourimahdavikouros comparisonofratesofprogressionofmacularoctmeasuresinglaucoma