Cargando…
The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy
To reduce noise pollution and consequently stress during robot-assisted laparoscopic radical prostatectomy (RALP) the aim of our study was to evaluate the silent operation theatre optimisation system (SOTOS) in its effectiveness. In the operating room (OR) the noise level is between 80 and 85 decibe...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer London
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7416589/ https://www.ncbi.nlm.nih.gov/pubmed/32776286 http://dx.doi.org/10.1007/s11701-020-01135-x |
_version_ | 1783569330357665792 |
---|---|
author | Leitsmann, Conrad Uhlig, Annemarie Popeneciu, I. Valentin Boos, Margarete Ahyai, Sascha A. Schmid, Marianne Wachter, Rolf Trojan, Lutz Friedrich, Martin |
author_facet | Leitsmann, Conrad Uhlig, Annemarie Popeneciu, I. Valentin Boos, Margarete Ahyai, Sascha A. Schmid, Marianne Wachter, Rolf Trojan, Lutz Friedrich, Martin |
author_sort | Leitsmann, Conrad |
collection | PubMed |
description | To reduce noise pollution and consequently stress during robot-assisted laparoscopic radical prostatectomy (RALP) the aim of our study was to evaluate the silent operation theatre optimisation system (SOTOS) in its effectiveness. In the operating room (OR) the noise level is between 80 and 85 decibel (dB). Noise corresponds to a major stress factor for surgical teams and especially surgeons. The use of the da Vinci surgical system entails an additional aspect of noise in the OR. The SOTOS surgical team used wired or wireless headphone/microphone combinations to communicate. We measured sound pressure levels in two different locations in the OR and the heart rate of every surgical team member as an indicator of the stress level. We further captured subjective acceptance of SOTOS as well as perioperative data such as surgical time. We prospectively randomised 32 RALP patients into two study arms. Sixteen surgeries were performed using SOTOS and 16 without (control). Overall, the mean sound pressure level in the SOTOS group was 3.6 dB lower compared to the control (p < 0.001). The highest sound pressure level measured was 96 dB in the control group. Mean heart rates were 81.3 beats/min for surgeons and 90.8 beats/min for circulating nurses. SOTOS had no statistically significant effect on mean heart rates of the operating team. Subjective acceptance of SOTO was high. Our prospective evaluation of SOTOS in RALP could show a significant noise reduction in the OR and a high acceptance by the surgical stuff. |
format | Online Article Text |
id | pubmed-7416589 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer London |
record_format | MEDLINE/PubMed |
spelling | pubmed-74165892020-08-10 The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy Leitsmann, Conrad Uhlig, Annemarie Popeneciu, I. Valentin Boos, Margarete Ahyai, Sascha A. Schmid, Marianne Wachter, Rolf Trojan, Lutz Friedrich, Martin J Robot Surg Original Article To reduce noise pollution and consequently stress during robot-assisted laparoscopic radical prostatectomy (RALP) the aim of our study was to evaluate the silent operation theatre optimisation system (SOTOS) in its effectiveness. In the operating room (OR) the noise level is between 80 and 85 decibel (dB). Noise corresponds to a major stress factor for surgical teams and especially surgeons. The use of the da Vinci surgical system entails an additional aspect of noise in the OR. The SOTOS surgical team used wired or wireless headphone/microphone combinations to communicate. We measured sound pressure levels in two different locations in the OR and the heart rate of every surgical team member as an indicator of the stress level. We further captured subjective acceptance of SOTOS as well as perioperative data such as surgical time. We prospectively randomised 32 RALP patients into two study arms. Sixteen surgeries were performed using SOTOS and 16 without (control). Overall, the mean sound pressure level in the SOTOS group was 3.6 dB lower compared to the control (p < 0.001). The highest sound pressure level measured was 96 dB in the control group. Mean heart rates were 81.3 beats/min for surgeons and 90.8 beats/min for circulating nurses. SOTOS had no statistically significant effect on mean heart rates of the operating team. Subjective acceptance of SOTO was high. Our prospective evaluation of SOTOS in RALP could show a significant noise reduction in the OR and a high acceptance by the surgical stuff. Springer London 2020-08-10 2021 /pmc/articles/PMC7416589/ /pubmed/32776286 http://dx.doi.org/10.1007/s11701-020-01135-x Text en © Springer-Verlag London Ltd., part of Springer Nature 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Article Leitsmann, Conrad Uhlig, Annemarie Popeneciu, I. Valentin Boos, Margarete Ahyai, Sascha A. Schmid, Marianne Wachter, Rolf Trojan, Lutz Friedrich, Martin The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title | The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title_full | The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title_fullStr | The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title_full_unstemmed | The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title_short | The Silent Operation Theatre Optimisation System (SOTOS(©)) to reduce noise pollution during da Vinci robot-assisted laparoscopic radical prostatectomy |
title_sort | silent operation theatre optimisation system (sotos(©)) to reduce noise pollution during da vinci robot-assisted laparoscopic radical prostatectomy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7416589/ https://www.ncbi.nlm.nih.gov/pubmed/32776286 http://dx.doi.org/10.1007/s11701-020-01135-x |
work_keys_str_mv | AT leitsmannconrad thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT uhligannemarie thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT popeneciuivalentin thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT boosmargarete thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT ahyaisaschaa thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT schmidmarianne thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT wachterrolf thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT trojanlutz thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT friedrichmartin thesilentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT leitsmannconrad silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT uhligannemarie silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT popeneciuivalentin silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT boosmargarete silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT ahyaisaschaa silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT schmidmarianne silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT wachterrolf silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT trojanlutz silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy AT friedrichmartin silentoperationtheatreoptimisationsystemsotostoreducenoisepollutionduringdavincirobotassistedlaparoscopicradicalprostatectomy |