Cargando…
Accidental intraoperative ingestion of a paralleling pin during implant placement
Foreign body ingestion although unusual may be possible during dental treatment when placing any implants, prosthetic crowns, restoration, endodontic treatment, or orthodontic treatment. When the ingestion occurs, it is always crucial to locate the foreign body within the patient's body by taki...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7418543/ https://www.ncbi.nlm.nih.gov/pubmed/32831514 http://dx.doi.org/10.4103/jisp.jisp_467_19 |
_version_ | 1783569710261993472 |
---|---|
author | Ramaraj, P. N. Ajeya Ranganathan, H. K. Nithin, V. M. Lakshmi, G. Vijaya |
author_facet | Ramaraj, P. N. Ajeya Ranganathan, H. K. Nithin, V. M. Lakshmi, G. Vijaya |
author_sort | Ramaraj, P. N. |
collection | PubMed |
description | Foreign body ingestion although unusual may be possible during dental treatment when placing any implants, prosthetic crowns, restoration, endodontic treatment, or orthodontic treatment. When the ingestion occurs, it is always crucial to locate the foreign body within the patient's body by taking bi-planar radiographs. Any features of airway distress or obstruction should be ruled out and if it is located in the gastrointestinal (GI) tract, the nature and size of the material will decide the protocol of retrieval of the ingested object. However, there is always a risk of intestinal perforations or obstructions secondary to the ingestion. Here is a case report wherein there was an accidental ingestion of the paralleling pin during the first stage of the implant placement with indications of various GI investigations and recommendations to avoid instrument ingestion. |
format | Online Article Text |
id | pubmed-7418543 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-74185432020-08-20 Accidental intraoperative ingestion of a paralleling pin during implant placement Ramaraj, P. N. Ajeya Ranganathan, H. K. Nithin, V. M. Lakshmi, G. Vijaya J Indian Soc Periodontol Case Report Foreign body ingestion although unusual may be possible during dental treatment when placing any implants, prosthetic crowns, restoration, endodontic treatment, or orthodontic treatment. When the ingestion occurs, it is always crucial to locate the foreign body within the patient's body by taking bi-planar radiographs. Any features of airway distress or obstruction should be ruled out and if it is located in the gastrointestinal (GI) tract, the nature and size of the material will decide the protocol of retrieval of the ingested object. However, there is always a risk of intestinal perforations or obstructions secondary to the ingestion. Here is a case report wherein there was an accidental ingestion of the paralleling pin during the first stage of the implant placement with indications of various GI investigations and recommendations to avoid instrument ingestion. Wolters Kluwer - Medknow 2020 2020-06-02 /pmc/articles/PMC7418543/ /pubmed/32831514 http://dx.doi.org/10.4103/jisp.jisp_467_19 Text en Copyright: © 2020 Indian Society of Periodontology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Ramaraj, P. N. Ajeya Ranganathan, H. K. Nithin, V. M. Lakshmi, G. Vijaya Accidental intraoperative ingestion of a paralleling pin during implant placement |
title | Accidental intraoperative ingestion of a paralleling pin during implant placement |
title_full | Accidental intraoperative ingestion of a paralleling pin during implant placement |
title_fullStr | Accidental intraoperative ingestion of a paralleling pin during implant placement |
title_full_unstemmed | Accidental intraoperative ingestion of a paralleling pin during implant placement |
title_short | Accidental intraoperative ingestion of a paralleling pin during implant placement |
title_sort | accidental intraoperative ingestion of a paralleling pin during implant placement |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7418543/ https://www.ncbi.nlm.nih.gov/pubmed/32831514 http://dx.doi.org/10.4103/jisp.jisp_467_19 |
work_keys_str_mv | AT ramarajpn accidentalintraoperativeingestionofaparallelingpinduringimplantplacement AT ajeyaranganathanhk accidentalintraoperativeingestionofaparallelingpinduringimplantplacement AT nithinvm accidentalintraoperativeingestionofaparallelingpinduringimplantplacement AT lakshmigvijaya accidentalintraoperativeingestionofaparallelingpinduringimplantplacement |