Cargando…
Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep: An RCT Comparing 4 Bearing Combinations
BACKGROUND: The ideal bearing combination for total hip arthroplasty (THA) remains debatable. Highly cross-linked polyethylene (XLPE) is widely used, but long-term wear rates are not fully known, nor is how much the initial “creep,” if any, affects overall wear. Additionally, the use of oxidized zir...
Autores principales: | Khoshbin, Amir, Wu, James, Ward, Sarah, Melo, Luana T., Schemitsch, Emil H., Waddell, James P., Atrey, Amit |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of Bone and Joint Surgery, Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7418907/ https://www.ncbi.nlm.nih.gov/pubmed/33123666 http://dx.doi.org/10.2106/JBJS.OA.19.00066 |