Cargando…

Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography

A large part of the worldwide population suffers from obstructive sleep apnea (OSA), a disorder impairing the restorative function of sleep and constituting a risk factor for several cardiovascular pathologies. The standard diagnostic metric to define OSA is the apnea–hypopnea index (AHI), typically...

Descripción completa

Detalles Bibliográficos
Autores principales: Papini, Gabriele B., Fonseca, Pedro, van Gilst, Merel M., Bergmans, Jan W. M., Vullings, Rik, Overeem, Sebastiaan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7421543/
https://www.ncbi.nlm.nih.gov/pubmed/32782313
http://dx.doi.org/10.1038/s41598-020-69935-7
_version_ 1783569985428258816
author Papini, Gabriele B.
Fonseca, Pedro
van Gilst, Merel M.
Bergmans, Jan W. M.
Vullings, Rik
Overeem, Sebastiaan
author_facet Papini, Gabriele B.
Fonseca, Pedro
van Gilst, Merel M.
Bergmans, Jan W. M.
Vullings, Rik
Overeem, Sebastiaan
author_sort Papini, Gabriele B.
collection PubMed
description A large part of the worldwide population suffers from obstructive sleep apnea (OSA), a disorder impairing the restorative function of sleep and constituting a risk factor for several cardiovascular pathologies. The standard diagnostic metric to define OSA is the apnea–hypopnea index (AHI), typically obtained by manually annotating polysomnographic recordings. However, this clinical procedure cannot be employed for screening and for long-term monitoring of OSA due to its obtrusiveness and cost. Here, we propose an automatic unobtrusive AHI estimation method fully based on wrist-worn reflective photoplethysmography (rPPG), employing a deep learning model exploiting cardiorespiratory and sleep information extracted from the rPPG signal trained with 250 recordings. We tested our method with an independent set of 188 heterogeneously disordered clinical recordings and we found it estimates the AHI with a good agreement to the gold standard polysomnography reference (correlation = 0.61, estimation error = 3±10 events/h). The estimated AHI was shown to reliably assess OSA severity (weighted Cohen’s kappa = 0.51) and screen for OSA (ROC–AUC = 0.84/0.86/0.85 for mild/moderate/severe OSA). These findings suggest that wrist-worn rPPG measurements that can be implemented in wearables such as smartwatches, have the potential to complement standard OSA diagnostic techniques by allowing unobtrusive sleep and respiratory monitoring.
format Online
Article
Text
id pubmed-7421543
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-74215432020-08-13 Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography Papini, Gabriele B. Fonseca, Pedro van Gilst, Merel M. Bergmans, Jan W. M. Vullings, Rik Overeem, Sebastiaan Sci Rep Article A large part of the worldwide population suffers from obstructive sleep apnea (OSA), a disorder impairing the restorative function of sleep and constituting a risk factor for several cardiovascular pathologies. The standard diagnostic metric to define OSA is the apnea–hypopnea index (AHI), typically obtained by manually annotating polysomnographic recordings. However, this clinical procedure cannot be employed for screening and for long-term monitoring of OSA due to its obtrusiveness and cost. Here, we propose an automatic unobtrusive AHI estimation method fully based on wrist-worn reflective photoplethysmography (rPPG), employing a deep learning model exploiting cardiorespiratory and sleep information extracted from the rPPG signal trained with 250 recordings. We tested our method with an independent set of 188 heterogeneously disordered clinical recordings and we found it estimates the AHI with a good agreement to the gold standard polysomnography reference (correlation = 0.61, estimation error = 3±10 events/h). The estimated AHI was shown to reliably assess OSA severity (weighted Cohen’s kappa = 0.51) and screen for OSA (ROC–AUC = 0.84/0.86/0.85 for mild/moderate/severe OSA). These findings suggest that wrist-worn rPPG measurements that can be implemented in wearables such as smartwatches, have the potential to complement standard OSA diagnostic techniques by allowing unobtrusive sleep and respiratory monitoring. Nature Publishing Group UK 2020-08-11 /pmc/articles/PMC7421543/ /pubmed/32782313 http://dx.doi.org/10.1038/s41598-020-69935-7 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Papini, Gabriele B.
Fonseca, Pedro
van Gilst, Merel M.
Bergmans, Jan W. M.
Vullings, Rik
Overeem, Sebastiaan
Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title_full Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title_fullStr Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title_full_unstemmed Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title_short Wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
title_sort wearable monitoring of sleep-disordered breathing: estimation of the apnea–hypopnea index using wrist-worn reflective photoplethysmography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7421543/
https://www.ncbi.nlm.nih.gov/pubmed/32782313
http://dx.doi.org/10.1038/s41598-020-69935-7
work_keys_str_mv AT papinigabrieleb wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography
AT fonsecapedro wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography
AT vangilstmerelm wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography
AT bergmansjanwm wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography
AT vullingsrik wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography
AT overeemsebastiaan wearablemonitoringofsleepdisorderedbreathingestimationoftheapneahypopneaindexusingwristwornreflectivephotoplethysmography