Cargando…

The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments

PURPOSE: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments. METHODS: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary...

Descripción completa

Detalles Bibliográficos
Autores principales: Jones, Pete R., Demaria, Giorgia, Tigchelaar, Iris, Asfaw, Daniel S., Edgar, David F., Campbell, Peter, Callaghan, Tamsin, Crabb, David P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7422775/
https://www.ncbi.nlm.nih.gov/pubmed/32855877
http://dx.doi.org/10.1167/tvst.9.8.31
_version_ 1783570066276614144
author Jones, Pete R.
Demaria, Giorgia
Tigchelaar, Iris
Asfaw, Daniel S.
Edgar, David F.
Campbell, Peter
Callaghan, Tamsin
Crabb, David P.
author_facet Jones, Pete R.
Demaria, Giorgia
Tigchelaar, Iris
Asfaw, Daniel S.
Edgar, David F.
Campbell, Peter
Callaghan, Tamsin
Crabb, David P.
author_sort Jones, Pete R.
collection PubMed
description PURPOSE: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments. METHODS: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test–retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli −3 dB or more brighter than threshold). RESULTS: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test–retest) measurement error (P = 0.003–0.007), and at least two others exhibited possible trends (P = 0.052–0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P < 0.001) and patients (r = 0.65, P < 0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P < 0.001). CONCLUSIONS: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials (“lapses”). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement). TRANSLATIONAL RELEVANCE: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure.
format Online
Article
Text
id pubmed-7422775
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-74227752020-08-26 The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments Jones, Pete R. Demaria, Giorgia Tigchelaar, Iris Asfaw, Daniel S. Edgar, David F. Campbell, Peter Callaghan, Tamsin Crabb, David P. Transl Vis Sci Technol Methods PURPOSE: To explore the feasibility of using various easy-to-obtain biomarkers to monitor non-compliance (measurement error) during visual field assessments. METHODS: Forty-two healthy adults (42 eyes) and seven glaucoma patients (14 eyes) underwent two same-day visual field assessments. An ordinary webcam was used to compute seven potential biomarkers of task compliance, based primarily on eye gaze, head pose, and facial expression. We quantified the association between each biomarker and measurement error, as defined by (1) test–retest differences in overall test scores (mean sensitivity), and (2) failures to respond to visible stimuli on individual trials (stimuli −3 dB or more brighter than threshold). RESULTS: In healthy eyes, three of the seven biomarkers were significantly associated with overall (test–retest) measurement error (P = 0.003–0.007), and at least two others exhibited possible trends (P = 0.052–0.060). The weighted linear sum of all seven biomarkers was associated with overall measurement error, in both healthy eyes (r = 0.51, P < 0.001) and patients (r = 0.65, P < 0.001). Five biomarkers were each associated with failures to respond to visible stimuli on individual trials (all P < 0.001). CONCLUSIONS: Inexpensive, autonomous measures of task compliance are associated with measurement error in visual field assessments, in terms of both the overall reliability of a test and failures to respond on particular trials (“lapses”). This could be helpful for identifying low-quality assessments and for improving assessment techniques (e.g., by discounting suspect responses or by automatically triggering comfort breaks or encouragement). TRANSLATIONAL RELEVANCE: This study explores a potential way of improving the reliability of visual field assessments, a crucial but notoriously unreliable clinical measure. The Association for Research in Vision and Ophthalmology 2020-07-20 /pmc/articles/PMC7422775/ /pubmed/32855877 http://dx.doi.org/10.1167/tvst.9.8.31 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Methods
Jones, Pete R.
Demaria, Giorgia
Tigchelaar, Iris
Asfaw, Daniel S.
Edgar, David F.
Campbell, Peter
Callaghan, Tamsin
Crabb, David P.
The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title_full The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title_fullStr The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title_full_unstemmed The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title_short The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments
title_sort human touch: using a webcam to autonomously monitor compliance during visual field assessments
topic Methods
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7422775/
https://www.ncbi.nlm.nih.gov/pubmed/32855877
http://dx.doi.org/10.1167/tvst.9.8.31
work_keys_str_mv AT jonespeter thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT demariagiorgia thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT tigchelaariris thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT asfawdaniels thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT edgardavidf thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT campbellpeter thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT callaghantamsin thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT crabbdavidp thehumantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT jonespeter humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT demariagiorgia humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT tigchelaariris humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT asfawdaniels humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT edgardavidf humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT campbellpeter humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT callaghantamsin humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments
AT crabbdavidp humantouchusingawebcamtoautonomouslymonitorcomplianceduringvisualfieldassessments