Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement
Georgia uses post-analytical tools through Collaborative Laboratory Integrated Reports (CLIR) to triage abnormal newborn screening (NBS) results for follow-up. Condition specific tools are used to assign each case a risk level, which is used to guide follow-up recommendations. Follow-up recommendati...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7422973/ https://www.ncbi.nlm.nih.gov/pubmed/33073017 http://dx.doi.org/10.3390/ijns6010020 |
_version_ | 1783570094962507776 |
---|---|
author | Hall, Patricia L. Wittenauer, Angela Hagar, Arthur |
author_facet | Hall, Patricia L. Wittenauer, Angela Hagar, Arthur |
author_sort | Hall, Patricia L. |
collection | PubMed |
description | Georgia uses post-analytical tools through Collaborative Laboratory Integrated Reports (CLIR) to triage abnormal newborn screening (NBS) results for follow-up. Condition specific tools are used to assign each case a risk level, which is used to guide follow-up recommendations. Follow-up recommendations include assessment by the child’s primary care provider as well as testing, either a repeat NBS or confirmatory testing. Triaging abnormal cases using these tools has been advantageous in managing the workflow for the follow-up team, as well as prioritizing cases that appropriately require more attention and resources. The initial goal in utilizing these tools was to reduce the amount of confirmatory testing, particularly for disorders where there are many false positives. We assessed the performance of these tools retrospectively for three of the most commonly detected conditions by tandem mass spectrometry in Georgia: phenylketonuria, medium chain acyl-CoA dehydrogenase deficiency and very long chain dehydrogenase deficiency. The post-analytical tools appropriately assigned all true positive cases to the higher levels of follow-up testing and reduced the level of intervention for a significant number of cases as well. Based on the experience gained from our utilization of the tools in the follow-up program, we are well situated to move forward with using the tools in a more prospective manner, and reduce the number of cases that will be reported, rather than just assigning resources appropriately at follow-up. Post-analytical tools are an improvement over trying to capture the variation in the newborn population using multiple cutoffs. It also easily identifies significant abnormalities that are unrelated to inherited disease, such as large amino acid elevations due to total parenteral nutrition. |
format | Online Article Text |
id | pubmed-7422973 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74229732020-10-15 Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement Hall, Patricia L. Wittenauer, Angela Hagar, Arthur Int J Neonatal Screen Article Georgia uses post-analytical tools through Collaborative Laboratory Integrated Reports (CLIR) to triage abnormal newborn screening (NBS) results for follow-up. Condition specific tools are used to assign each case a risk level, which is used to guide follow-up recommendations. Follow-up recommendations include assessment by the child’s primary care provider as well as testing, either a repeat NBS or confirmatory testing. Triaging abnormal cases using these tools has been advantageous in managing the workflow for the follow-up team, as well as prioritizing cases that appropriately require more attention and resources. The initial goal in utilizing these tools was to reduce the amount of confirmatory testing, particularly for disorders where there are many false positives. We assessed the performance of these tools retrospectively for three of the most commonly detected conditions by tandem mass spectrometry in Georgia: phenylketonuria, medium chain acyl-CoA dehydrogenase deficiency and very long chain dehydrogenase deficiency. The post-analytical tools appropriately assigned all true positive cases to the higher levels of follow-up testing and reduced the level of intervention for a significant number of cases as well. Based on the experience gained from our utilization of the tools in the follow-up program, we are well situated to move forward with using the tools in a more prospective manner, and reduce the number of cases that will be reported, rather than just assigning resources appropriately at follow-up. Post-analytical tools are an improvement over trying to capture the variation in the newborn population using multiple cutoffs. It also easily identifies significant abnormalities that are unrelated to inherited disease, such as large amino acid elevations due to total parenteral nutrition. MDPI 2020-03-14 /pmc/articles/PMC7422973/ /pubmed/33073017 http://dx.doi.org/10.3390/ijns6010020 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hall, Patricia L. Wittenauer, Angela Hagar, Arthur Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title | Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title_full | Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title_fullStr | Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title_full_unstemmed | Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title_short | Post-Analytical Tools for the Triage of Newborn Screening Results in Follow-up Can Reduce Confirmatory Testing and Guide Performance Improvement |
title_sort | post-analytical tools for the triage of newborn screening results in follow-up can reduce confirmatory testing and guide performance improvement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7422973/ https://www.ncbi.nlm.nih.gov/pubmed/33073017 http://dx.doi.org/10.3390/ijns6010020 |
work_keys_str_mv | AT hallpatricial postanalyticaltoolsforthetriageofnewbornscreeningresultsinfollowupcanreduceconfirmatorytestingandguideperformanceimprovement AT wittenauerangela postanalyticaltoolsforthetriageofnewbornscreeningresultsinfollowupcanreduceconfirmatorytestingandguideperformanceimprovement AT hagararthur postanalyticaltoolsforthetriageofnewbornscreeningresultsinfollowupcanreduceconfirmatorytestingandguideperformanceimprovement |