A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study

BACKGROUND: Smartphone-based fundus imaging allows for mobile and inexpensive fundus examination with the potential to revolutionize eye care, particularly in lower-resource settings. However, most smartphone-based fundus imaging adapters convey image quality not comparable to conventional fundus im...

Descripción completa

Detalles Bibliográficos
Autores principales: Wintergerst, Maximilian W M, Jansen, Linus G, Holz, Frank G, Finger, Robert P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424474/
https://www.ncbi.nlm.nih.gov/pubmed/32723717
http://dx.doi.org/10.2196/17480
_version_ 1783570345907716096
author Wintergerst, Maximilian W M
Jansen, Linus G
Holz, Frank G
Finger, Robert P
author_facet Wintergerst, Maximilian W M
Jansen, Linus G
Holz, Frank G
Finger, Robert P
author_sort Wintergerst, Maximilian W M
collection PubMed
description BACKGROUND: Smartphone-based fundus imaging allows for mobile and inexpensive fundus examination with the potential to revolutionize eye care, particularly in lower-resource settings. However, most smartphone-based fundus imaging adapters convey image quality not comparable to conventional fundus imaging. OBJECTIVE: The purpose of this study was to evaluate a novel smartphone-based fundus imaging device for documentation of a variety of retinal/vitreous pathologies in a patient sample with wide refraction and age ranges. METHODS: Participants’ eyes were dilated and imaged with the iC2 funduscope (HEINE Optotechnik) using an Apple iPhone 6 in single-image acquisition (image resolution of 2448 × 3264 pixels) or video mode (1248 × 1664 pixels) and a subgroup of participants was also examined by conventional fundus imaging (Zeiss VISUCAM 500). Smartphone-based image quality was compared to conventional fundus imaging in terms of sharpness (focus), reflex artifacts, contrast, and illumination on semiquantitative scales. RESULTS: A total of 47 eyes from 32 participants (age: mean 62.3, SD 19.8 years; range 7-93; spherical equivalent: mean –0.78, SD 3.21 D; range: –7.88 to +7.0 D) were included in the study. Mean (SD) visual acuity (logMAR) was 0.48 (0.66; range 0-2.3); 30% (14/47) of the eyes were pseudophakic. Image quality was sufficient in all eyes irrespective of refraction. Images acquired with conventional fundus imaging were sharper and had less reflex artifacts, and there was no significant difference in contrast and illumination (P<.001, P=.03, and P=.10, respectively). When comparing image quality at the posterior pole, the mid periphery, and the far periphery, glare increased as images were acquired from a more peripheral part of the retina. Reflex artifacts were more frequent in pseudophakic eyes. Image acquisition was also possible in children. Documentation of deep optic nerve cups in video mode conveyed a mock 3D impression. CONCLUSIONS: Image quality of conventional fundus imaging was superior to that of smartphone-based fundus imaging, although this novel smartphone-based fundus imaging device achieved image quality high enough to document various fundus pathologies including only subtle findings. High-quality smartphone-based fundus imaging might represent a mobile alternative for fundus documentation in clinical practice.
format Online
Article
Text
id pubmed-7424474
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-74244742020-08-20 A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study Wintergerst, Maximilian W M Jansen, Linus G Holz, Frank G Finger, Robert P JMIR Mhealth Uhealth Original Paper BACKGROUND: Smartphone-based fundus imaging allows for mobile and inexpensive fundus examination with the potential to revolutionize eye care, particularly in lower-resource settings. However, most smartphone-based fundus imaging adapters convey image quality not comparable to conventional fundus imaging. OBJECTIVE: The purpose of this study was to evaluate a novel smartphone-based fundus imaging device for documentation of a variety of retinal/vitreous pathologies in a patient sample with wide refraction and age ranges. METHODS: Participants’ eyes were dilated and imaged with the iC2 funduscope (HEINE Optotechnik) using an Apple iPhone 6 in single-image acquisition (image resolution of 2448 × 3264 pixels) or video mode (1248 × 1664 pixels) and a subgroup of participants was also examined by conventional fundus imaging (Zeiss VISUCAM 500). Smartphone-based image quality was compared to conventional fundus imaging in terms of sharpness (focus), reflex artifacts, contrast, and illumination on semiquantitative scales. RESULTS: A total of 47 eyes from 32 participants (age: mean 62.3, SD 19.8 years; range 7-93; spherical equivalent: mean –0.78, SD 3.21 D; range: –7.88 to +7.0 D) were included in the study. Mean (SD) visual acuity (logMAR) was 0.48 (0.66; range 0-2.3); 30% (14/47) of the eyes were pseudophakic. Image quality was sufficient in all eyes irrespective of refraction. Images acquired with conventional fundus imaging were sharper and had less reflex artifacts, and there was no significant difference in contrast and illumination (P<.001, P=.03, and P=.10, respectively). When comparing image quality at the posterior pole, the mid periphery, and the far periphery, glare increased as images were acquired from a more peripheral part of the retina. Reflex artifacts were more frequent in pseudophakic eyes. Image acquisition was also possible in children. Documentation of deep optic nerve cups in video mode conveyed a mock 3D impression. CONCLUSIONS: Image quality of conventional fundus imaging was superior to that of smartphone-based fundus imaging, although this novel smartphone-based fundus imaging device achieved image quality high enough to document various fundus pathologies including only subtle findings. High-quality smartphone-based fundus imaging might represent a mobile alternative for fundus documentation in clinical practice. JMIR Publications 2020-07-29 /pmc/articles/PMC7424474/ /pubmed/32723717 http://dx.doi.org/10.2196/17480 Text en ©Maximilian W M Wintergerst, Linus G Jansen, Frank G Holz, Robert P Finger. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 29.07.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Wintergerst, Maximilian W M
Jansen, Linus G
Holz, Frank G
Finger, Robert P
A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title_full A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title_fullStr A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title_full_unstemmed A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title_short A Novel Device for Smartphone-Based Fundus Imaging and Documentation in Clinical Practice: Comparative Image Analysis Study
title_sort novel device for smartphone-based fundus imaging and documentation in clinical practice: comparative image analysis study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424474/
https://www.ncbi.nlm.nih.gov/pubmed/32723717
http://dx.doi.org/10.2196/17480
work_keys_str_mv AT wintergerstmaximilianwm anoveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT jansenlinusg anoveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT holzfrankg anoveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT fingerrobertp anoveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT wintergerstmaximilianwm noveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT jansenlinusg noveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT holzfrankg noveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy
AT fingerrobertp noveldeviceforsmartphonebasedfundusimaginganddocumentationinclinicalpracticecomparativeimageanalysisstudy