Cargando…
Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals
BACKGROUND: Percutaneous renal biopsy (PRB) is the primary biopsy technique and it was used by 16G needles or 18G needles in China, but there is controversy about the effect and safety of the two different diameters. The study aims to compare the adequacy, complication rate and pathological classifi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424979/ https://www.ncbi.nlm.nih.gov/pubmed/32787784 http://dx.doi.org/10.1186/s12882-020-01987-3 |
_version_ | 1783570410846027776 |
---|---|
author | Xie, Weiji Xu, Jing Xie, Yi Lin, Zhijun Xu, Xiaochang Zhang, Xialan Zhang, Yimin |
author_facet | Xie, Weiji Xu, Jing Xie, Yi Lin, Zhijun Xu, Xiaochang Zhang, Xialan Zhang, Yimin |
author_sort | Xie, Weiji |
collection | PubMed |
description | BACKGROUND: Percutaneous renal biopsy (PRB) is the primary biopsy technique and it was used by 16G needles or 18G needles in China, but there is controversy about the effect and safety of the two different diameters. The study aims to compare the adequacy, complication rate and pathological classification when using 18G vs. 16G needles to perform renal biopsy with ultrasound-guidedance on native kidneys in Chinese individuals. METHODS: We retrospectively analyzed the number of glomeruli, adequate sample rates, complication rates and pathological classification in 270 patients with the use of 18G or 16G needles from January 2011 to May 2017 and verified whether the needle gauge affected the disease diagnosis. RESULTS: A total of 270 kidney biopsies were performed. Among them,72 were performed with 18G needles, and 198 were performed with 16G needles. There was no difference in the number of glomeruli under light microscope using 18G relative to 16G needles (24 ± 11 vs. 25 ± 11, p = 0.265), whereas more glomeruli were found in the 16G group than in the 16G group using immunofluorescence microscopy (3 ± 2 vs. 5 ± 3, p < 0.05). There was no significant difference in the adequate sample rates between the 18G group and the 16G group (90.28% vs. 93.94%, p = 0.298). Minor complications including the incidence of lumbar or abdominal pain (4.17% vs. 7.07%, p = 0.57), gross hematuria (4.17% vs. 3.54%, p = 0.729), and perinephric hematoma without symptoms (4.17% vs. 1.52%, p = 0.195), were not significantly different between the 18G and 16G groups. In the 16G group, 2 cases of serious complications occurred: severe gross hematuria requiring blood transfusion and retroperitoneal hematoma requiring surgery. No serious complications were observed in the 18G group, although there was no significant difference in serious complications rates between the 18G and 16G groups (0% vs. 1.02%, p = 1). CONCLUSION: There was no significant difference in the number of glomeruli, adequate sample rates, or complication rates when using 18G or 16G needles to perform renal biopsy, and the use of an 18G needle with a smaller diameter did not affect the pathological diagnosis or classification of IgA nephropathy and lupus nephritis. |
format | Online Article Text |
id | pubmed-7424979 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-74249792020-08-16 Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals Xie, Weiji Xu, Jing Xie, Yi Lin, Zhijun Xu, Xiaochang Zhang, Xialan Zhang, Yimin BMC Nephrol Research Article BACKGROUND: Percutaneous renal biopsy (PRB) is the primary biopsy technique and it was used by 16G needles or 18G needles in China, but there is controversy about the effect and safety of the two different diameters. The study aims to compare the adequacy, complication rate and pathological classification when using 18G vs. 16G needles to perform renal biopsy with ultrasound-guidedance on native kidneys in Chinese individuals. METHODS: We retrospectively analyzed the number of glomeruli, adequate sample rates, complication rates and pathological classification in 270 patients with the use of 18G or 16G needles from January 2011 to May 2017 and verified whether the needle gauge affected the disease diagnosis. RESULTS: A total of 270 kidney biopsies were performed. Among them,72 were performed with 18G needles, and 198 were performed with 16G needles. There was no difference in the number of glomeruli under light microscope using 18G relative to 16G needles (24 ± 11 vs. 25 ± 11, p = 0.265), whereas more glomeruli were found in the 16G group than in the 16G group using immunofluorescence microscopy (3 ± 2 vs. 5 ± 3, p < 0.05). There was no significant difference in the adequate sample rates between the 18G group and the 16G group (90.28% vs. 93.94%, p = 0.298). Minor complications including the incidence of lumbar or abdominal pain (4.17% vs. 7.07%, p = 0.57), gross hematuria (4.17% vs. 3.54%, p = 0.729), and perinephric hematoma without symptoms (4.17% vs. 1.52%, p = 0.195), were not significantly different between the 18G and 16G groups. In the 16G group, 2 cases of serious complications occurred: severe gross hematuria requiring blood transfusion and retroperitoneal hematoma requiring surgery. No serious complications were observed in the 18G group, although there was no significant difference in serious complications rates between the 18G and 16G groups (0% vs. 1.02%, p = 1). CONCLUSION: There was no significant difference in the number of glomeruli, adequate sample rates, or complication rates when using 18G or 16G needles to perform renal biopsy, and the use of an 18G needle with a smaller diameter did not affect the pathological diagnosis or classification of IgA nephropathy and lupus nephritis. BioMed Central 2020-08-12 /pmc/articles/PMC7424979/ /pubmed/32787784 http://dx.doi.org/10.1186/s12882-020-01987-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Xie, Weiji Xu, Jing Xie, Yi Lin, Zhijun Xu, Xiaochang Zhang, Xialan Zhang, Yimin Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title | Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title_full | Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title_fullStr | Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title_full_unstemmed | Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title_short | Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals |
title_sort | adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in chinese individuals |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424979/ https://www.ncbi.nlm.nih.gov/pubmed/32787784 http://dx.doi.org/10.1186/s12882-020-01987-3 |
work_keys_str_mv | AT xieweiji adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT xujing adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT xieyi adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT linzhijun adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT xuxiaochang adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT zhangxialan adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals AT zhangyimin adequacyandcomplicationratesofpercutaneousrenalbiopsywith18vs16gaugeneedlesinnativekidneysinchineseindividuals |