Cargando…
Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems
BACKGROUND: COVID-19 can be transmitted directly through respiratory droplets or indirectly through fomites. SARS-CoV-2 has been detected on various environmental surfaces, air samples and sewage in hospital and community settings. METHODS: Environmental samples were collected from a ferryboat durin...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier GmbH.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425762/ https://www.ncbi.nlm.nih.gov/pubmed/32823069 http://dx.doi.org/10.1016/j.ijheh.2020.113599 |
_version_ | 1783570558614503424 |
---|---|
author | Mouchtouri, Varvara A. Koureas, Michalis Kyritsi, Maria Vontas, Alexandros Kourentis, Leonidas Sapounas, Spyros Rigakos, George Petinaki, Efthimia Tsiodras, Sotirios Hadjichristodoulou, Christos |
author_facet | Mouchtouri, Varvara A. Koureas, Michalis Kyritsi, Maria Vontas, Alexandros Kourentis, Leonidas Sapounas, Spyros Rigakos, George Petinaki, Efthimia Tsiodras, Sotirios Hadjichristodoulou, Christos |
author_sort | Mouchtouri, Varvara A. |
collection | PubMed |
description | BACKGROUND: COVID-19 can be transmitted directly through respiratory droplets or indirectly through fomites. SARS-CoV-2 has been detected on various environmental surfaces, air samples and sewage in hospital and community settings. METHODS: Environmental samples were collected from a ferryboat during a COVID-19 ongoing outbreak investigation and a nursing home and from three COVID-19 isolation hospital wards and a long-term care facility where asymptomatic COVID-19 cases were isolated. Samples were tested by real-time reverse transcriptase–polymerase chain reaction. RESULTS: SARS-CoV-2 was detected on swab samples taken from surfaces of food preparation and service areas, hospital isolation wards, an air exhaust duct screen, air-conditioning filter, sewage treatment unit and air sample during investigations conducted in response to COVID-19 outbreaks on a ferryboat, nursing home, isolation facility and COVID-19 hospital wards. DISCUSSION: Food preparation areas and utensils can be contaminated during COVID-19 outbreaks. Respiratory droplets/nuclei from infected persons can be displaced by the air flow and deposited on surfaces. It can be assumed that in the same manner, air flow could transfer and deposit infected respiratory droplets/nuclei from infected persons to the mucous membranes of persons standing against the air flow direction. |
format | Online Article Text |
id | pubmed-7425762 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Published by Elsevier GmbH. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74257622020-08-14 Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems Mouchtouri, Varvara A. Koureas, Michalis Kyritsi, Maria Vontas, Alexandros Kourentis, Leonidas Sapounas, Spyros Rigakos, George Petinaki, Efthimia Tsiodras, Sotirios Hadjichristodoulou, Christos Int J Hyg Environ Health Short Communication BACKGROUND: COVID-19 can be transmitted directly through respiratory droplets or indirectly through fomites. SARS-CoV-2 has been detected on various environmental surfaces, air samples and sewage in hospital and community settings. METHODS: Environmental samples were collected from a ferryboat during a COVID-19 ongoing outbreak investigation and a nursing home and from three COVID-19 isolation hospital wards and a long-term care facility where asymptomatic COVID-19 cases were isolated. Samples were tested by real-time reverse transcriptase–polymerase chain reaction. RESULTS: SARS-CoV-2 was detected on swab samples taken from surfaces of food preparation and service areas, hospital isolation wards, an air exhaust duct screen, air-conditioning filter, sewage treatment unit and air sample during investigations conducted in response to COVID-19 outbreaks on a ferryboat, nursing home, isolation facility and COVID-19 hospital wards. DISCUSSION: Food preparation areas and utensils can be contaminated during COVID-19 outbreaks. Respiratory droplets/nuclei from infected persons can be displaced by the air flow and deposited on surfaces. It can be assumed that in the same manner, air flow could transfer and deposit infected respiratory droplets/nuclei from infected persons to the mucous membranes of persons standing against the air flow direction. Published by Elsevier GmbH. 2020-09 2020-08-13 /pmc/articles/PMC7425762/ /pubmed/32823069 http://dx.doi.org/10.1016/j.ijheh.2020.113599 Text en © 2020 Published by Elsevier GmbH. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Short Communication Mouchtouri, Varvara A. Koureas, Michalis Kyritsi, Maria Vontas, Alexandros Kourentis, Leonidas Sapounas, Spyros Rigakos, George Petinaki, Efthimia Tsiodras, Sotirios Hadjichristodoulou, Christos Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title | Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title_full | Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title_fullStr | Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title_full_unstemmed | Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title_short | Environmental contamination of SARS-CoV-2 on surfaces, air-conditioner and ventilation systems |
title_sort | environmental contamination of sars-cov-2 on surfaces, air-conditioner and ventilation systems |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425762/ https://www.ncbi.nlm.nih.gov/pubmed/32823069 http://dx.doi.org/10.1016/j.ijheh.2020.113599 |
work_keys_str_mv | AT mouchtourivarvaraa environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT koureasmichalis environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT kyritsimaria environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT vontasalexandros environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT kourentisleonidas environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT sapounasspyros environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT rigakosgeorge environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT petinakiefthimia environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT tsiodrassotirios environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems AT hadjichristodoulouchristos environmentalcontaminationofsarscov2onsurfacesairconditionerandventilationsystems |