Cargando…
Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered porta...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425952/ https://www.ncbi.nlm.nih.gov/pubmed/32790732 http://dx.doi.org/10.1371/journal.pone.0237604 |
_version_ | 1783570597438029824 |
---|---|
author | Qian, Li Wenlu, Zhang Hong, Wang Juan, Deng Xinli, Tian Linlin, Wang Hong, Sha |
author_facet | Qian, Li Wenlu, Zhang Hong, Wang Juan, Deng Xinli, Tian Linlin, Wang Hong, Sha |
author_sort | Qian, Li |
collection | PubMed |
description | This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered portable usage, NO micro-channel plasma reactions induced by a continuous discharge arc were employed. A single-use airway tube could be combined with an intubation tube in clinical applications. In the experiment, a switching transistor controlled high frequency DC (12.5 kHz) was used to create a continuous discharge arc between two stainless steel electrodes (1-mm separation) after high-voltage breakthrough. A rotate instrument was employed to change the direction angle between the airflow and discharge arc, tube filled with Calcium hydroxide connected with gas outlet for reducing NO(2), gas flow rate and input voltage were evaluated separately with concentration of NO and NO(2)/NO ratio. Results showed that a 2 L/min air flow direction from the cathode to the anode of electrodes (direction angle was zero) under 4 V input voltages produced 32.5±3.8 ppm NO, and the NO(2)/NO ratio reduced to less than 10%, stable output of nitric oxide might be convenient and effective for NO inhalation therapy. Modularization of the design produced a portable NO inhalation device that has potential for use in clinical applications as it is low cost, easy to disinfect, consumes low levels of energy and is ready to use. |
format | Online Article Text |
id | pubmed-7425952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-74259522020-08-20 Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy Qian, Li Wenlu, Zhang Hong, Wang Juan, Deng Xinli, Tian Linlin, Wang Hong, Sha PLoS One Research Article This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered portable usage, NO micro-channel plasma reactions induced by a continuous discharge arc were employed. A single-use airway tube could be combined with an intubation tube in clinical applications. In the experiment, a switching transistor controlled high frequency DC (12.5 kHz) was used to create a continuous discharge arc between two stainless steel electrodes (1-mm separation) after high-voltage breakthrough. A rotate instrument was employed to change the direction angle between the airflow and discharge arc, tube filled with Calcium hydroxide connected with gas outlet for reducing NO(2), gas flow rate and input voltage were evaluated separately with concentration of NO and NO(2)/NO ratio. Results showed that a 2 L/min air flow direction from the cathode to the anode of electrodes (direction angle was zero) under 4 V input voltages produced 32.5±3.8 ppm NO, and the NO(2)/NO ratio reduced to less than 10%, stable output of nitric oxide might be convenient and effective for NO inhalation therapy. Modularization of the design produced a portable NO inhalation device that has potential for use in clinical applications as it is low cost, easy to disinfect, consumes low levels of energy and is ready to use. Public Library of Science 2020-08-13 /pmc/articles/PMC7425952/ /pubmed/32790732 http://dx.doi.org/10.1371/journal.pone.0237604 Text en © 2020 Qian et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Qian, Li Wenlu, Zhang Hong, Wang Juan, Deng Xinli, Tian Linlin, Wang Hong, Sha Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title | Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title_full | Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title_fullStr | Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title_full_unstemmed | Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title_short | Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
title_sort | design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425952/ https://www.ncbi.nlm.nih.gov/pubmed/32790732 http://dx.doi.org/10.1371/journal.pone.0237604 |
work_keys_str_mv | AT qianli designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT wenluzhang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT hongwang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT juandeng designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT xinlitian designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT linlinwang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy AT hongsha designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy |