Cargando…

Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy

This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered porta...

Descripción completa

Detalles Bibliográficos
Autores principales: Qian, Li, Wenlu, Zhang, Hong, Wang, Juan, Deng, Xinli, Tian, Linlin, Wang, Hong, Sha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425952/
https://www.ncbi.nlm.nih.gov/pubmed/32790732
http://dx.doi.org/10.1371/journal.pone.0237604
_version_ 1783570597438029824
author Qian, Li
Wenlu, Zhang
Hong, Wang
Juan, Deng
Xinli, Tian
Linlin, Wang
Hong, Sha
author_facet Qian, Li
Wenlu, Zhang
Hong, Wang
Juan, Deng
Xinli, Tian
Linlin, Wang
Hong, Sha
author_sort Qian, Li
collection PubMed
description This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered portable usage, NO micro-channel plasma reactions induced by a continuous discharge arc were employed. A single-use airway tube could be combined with an intubation tube in clinical applications. In the experiment, a switching transistor controlled high frequency DC (12.5 kHz) was used to create a continuous discharge arc between two stainless steel electrodes (1-mm separation) after high-voltage breakthrough. A rotate instrument was employed to change the direction angle between the airflow and discharge arc, tube filled with Calcium hydroxide connected with gas outlet for reducing NO(2), gas flow rate and input voltage were evaluated separately with concentration of NO and NO(2)/NO ratio. Results showed that a 2 L/min air flow direction from the cathode to the anode of electrodes (direction angle was zero) under 4 V input voltages produced 32.5±3.8 ppm NO, and the NO(2)/NO ratio reduced to less than 10%, stable output of nitric oxide might be convenient and effective for NO inhalation therapy. Modularization of the design produced a portable NO inhalation device that has potential for use in clinical applications as it is low cost, easy to disinfect, consumes low levels of energy and is ready to use.
format Online
Article
Text
id pubmed-7425952
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-74259522020-08-20 Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy Qian, Li Wenlu, Zhang Hong, Wang Juan, Deng Xinli, Tian Linlin, Wang Hong, Sha PLoS One Research Article This study investigated the efficiency of a portable nitric oxide (NO) inhalation device through optimizing its design and structure. The portable rescue device could be used in clinical applications in outbreaks of viral pneumonia such as SARS. To reduce energy consumption for battery-powered portable usage, NO micro-channel plasma reactions induced by a continuous discharge arc were employed. A single-use airway tube could be combined with an intubation tube in clinical applications. In the experiment, a switching transistor controlled high frequency DC (12.5 kHz) was used to create a continuous discharge arc between two stainless steel electrodes (1-mm separation) after high-voltage breakthrough. A rotate instrument was employed to change the direction angle between the airflow and discharge arc, tube filled with Calcium hydroxide connected with gas outlet for reducing NO(2), gas flow rate and input voltage were evaluated separately with concentration of NO and NO(2)/NO ratio. Results showed that a 2 L/min air flow direction from the cathode to the anode of electrodes (direction angle was zero) under 4 V input voltages produced 32.5±3.8 ppm NO, and the NO(2)/NO ratio reduced to less than 10%, stable output of nitric oxide might be convenient and effective for NO inhalation therapy. Modularization of the design produced a portable NO inhalation device that has potential for use in clinical applications as it is low cost, easy to disinfect, consumes low levels of energy and is ready to use. Public Library of Science 2020-08-13 /pmc/articles/PMC7425952/ /pubmed/32790732 http://dx.doi.org/10.1371/journal.pone.0237604 Text en © 2020 Qian et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Qian, Li
Wenlu, Zhang
Hong, Wang
Juan, Deng
Xinli, Tian
Linlin, Wang
Hong, Sha
Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title_full Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title_fullStr Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title_full_unstemmed Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title_short Design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
title_sort design and study of nitric oxide portable producing device using continuous discharging arc plasma reaction keeping low energy efficiency for viral pneumonia emergency therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7425952/
https://www.ncbi.nlm.nih.gov/pubmed/32790732
http://dx.doi.org/10.1371/journal.pone.0237604
work_keys_str_mv AT qianli designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT wenluzhang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT hongwang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT juandeng designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT xinlitian designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT linlinwang designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy
AT hongsha designandstudyofnitricoxideportableproducingdeviceusingcontinuousdischargingarcplasmareactionkeepinglowenergyefficiencyforviralpneumoniaemergencytherapy