Cargando…
Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease
OBJECTIVE: Thromboelastography (TEG) may provide rapid and clinically important coagulation information in acutely ill patients with chronic liver disease (CLD). Our objective was to describe the relationship between TEG and conventional coagulation tests (CCTs), which has not been previously explor...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7427018/ https://www.ncbi.nlm.nih.gov/pubmed/32496878 http://dx.doi.org/10.1177/1076029620925915 |
_version_ | 1783570806239920128 |
---|---|
author | Lloyd-Donald, Patryck Vasudevan, Abhinav Angus, Peter Gow, Paul Mårtensson, Johan Glassford, Neil Eastwood, Glenn M. Hart, Graeme K. Jones, Daryl Weinberg, Laurence Bellomo, Rinaldo |
author_facet | Lloyd-Donald, Patryck Vasudevan, Abhinav Angus, Peter Gow, Paul Mårtensson, Johan Glassford, Neil Eastwood, Glenn M. Hart, Graeme K. Jones, Daryl Weinberg, Laurence Bellomo, Rinaldo |
author_sort | Lloyd-Donald, Patryck |
collection | PubMed |
description | OBJECTIVE: Thromboelastography (TEG) may provide rapid and clinically important coagulation information in acutely ill patients with chronic liver disease (CLD). Our objective was to describe the relationship between TEG and conventional coagulation tests (CCTs), which has not been previously explored in this population. METHODS: In acutely ill patients with severe CLD (Child-Pugh score > 9, category C), we conducted a prospective observational study investigating coagulation assessment as measured by both CCTs and TEG. We used quantile regression to explore 30 associations between TEG parameters and corresponding CCTs. We compared TEG and CCT measures of coagulation initiation, clot formation, clot strength, and fibrinolysis. RESULTS: We studied 34 patients on a total of 109 occasions. We observed inconsistent associations between TEG and CCT measures of coagulation initiation: TEG (citrated kaolin [CK] assay) standard reaction time and international normalized ratio: R (2) = 0.117 (P = .044). Conversely, there were strong and consistent associations between tests of clot formation: TEG (CK) kinetics time and fibrinogen: R (2) = 0.202 (P < .0001) and TEG (CK) α angle and fibrinogen 0.263 (P < .0001). We also observed strong associations between tests of clot strength, specifically TEG MA and conventional fibrinogen levels, across all TEG assays: MA (CK) and fibrinogen: R (2) = 0.485 (P < .0001). There were no associations between TEG and D-dimer levels. CONCLUSIONS: In acutely ill patients with CLD, there are strong and consistent associations between TEG measures of clot formation and clot strength and conventional fibrinogen levels. There are weak and/or inconsistent associations between TEG and all other conventional measures of coagulation. |
format | Online Article Text |
id | pubmed-7427018 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-74270182020-08-25 Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease Lloyd-Donald, Patryck Vasudevan, Abhinav Angus, Peter Gow, Paul Mårtensson, Johan Glassford, Neil Eastwood, Glenn M. Hart, Graeme K. Jones, Daryl Weinberg, Laurence Bellomo, Rinaldo Clin Appl Thromb Hemost Original Article OBJECTIVE: Thromboelastography (TEG) may provide rapid and clinically important coagulation information in acutely ill patients with chronic liver disease (CLD). Our objective was to describe the relationship between TEG and conventional coagulation tests (CCTs), which has not been previously explored in this population. METHODS: In acutely ill patients with severe CLD (Child-Pugh score > 9, category C), we conducted a prospective observational study investigating coagulation assessment as measured by both CCTs and TEG. We used quantile regression to explore 30 associations between TEG parameters and corresponding CCTs. We compared TEG and CCT measures of coagulation initiation, clot formation, clot strength, and fibrinolysis. RESULTS: We studied 34 patients on a total of 109 occasions. We observed inconsistent associations between TEG and CCT measures of coagulation initiation: TEG (citrated kaolin [CK] assay) standard reaction time and international normalized ratio: R (2) = 0.117 (P = .044). Conversely, there were strong and consistent associations between tests of clot formation: TEG (CK) kinetics time and fibrinogen: R (2) = 0.202 (P < .0001) and TEG (CK) α angle and fibrinogen 0.263 (P < .0001). We also observed strong associations between tests of clot strength, specifically TEG MA and conventional fibrinogen levels, across all TEG assays: MA (CK) and fibrinogen: R (2) = 0.485 (P < .0001). There were no associations between TEG and D-dimer levels. CONCLUSIONS: In acutely ill patients with CLD, there are strong and consistent associations between TEG measures of clot formation and clot strength and conventional fibrinogen levels. There are weak and/or inconsistent associations between TEG and all other conventional measures of coagulation. SAGE Publications 2020-06-04 /pmc/articles/PMC7427018/ /pubmed/32496878 http://dx.doi.org/10.1177/1076029620925915 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Lloyd-Donald, Patryck Vasudevan, Abhinav Angus, Peter Gow, Paul Mårtensson, Johan Glassford, Neil Eastwood, Glenn M. Hart, Graeme K. Jones, Daryl Weinberg, Laurence Bellomo, Rinaldo Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title | Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title_full | Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title_fullStr | Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title_full_unstemmed | Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title_short | Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease |
title_sort | comparison of thromboelastography and conventional coagulation tests in patients with severe liver disease |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7427018/ https://www.ncbi.nlm.nih.gov/pubmed/32496878 http://dx.doi.org/10.1177/1076029620925915 |
work_keys_str_mv | AT lloyddonaldpatryck comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT vasudevanabhinav comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT anguspeter comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT gowpaul comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT martenssonjohan comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT glassfordneil comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT eastwoodglennm comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT hartgraemek comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT jonesdaryl comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT weinberglaurence comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease AT bellomorinaldo comparisonofthromboelastographyandconventionalcoagulationtestsinpatientswithsevereliverdisease |