Cargando…

Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry

Accurate dosimetry for a real wireless power transfer system (WPT) using electromagnetic resonance and electromagnetic induction requires an accurate description of the field formed by the system. In particular, the electromagnetic field depends on factors such as the construction of the transmittin...

Descripción completa

Detalles Bibliográficos
Autor principal: Park, SangWook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7428189/
https://www.ncbi.nlm.nih.gov/pubmed/32797050
http://dx.doi.org/10.1371/journal.pone.0236929
_version_ 1783571023491235840
author Park, SangWook
author_facet Park, SangWook
author_sort Park, SangWook
collection PubMed
description Accurate dosimetry for a real wireless power transfer system (WPT) using electromagnetic resonance and electromagnetic induction requires an accurate description of the field formed by the system. In particular, the electromagnetic field depends on factors such as the construction of the transmitting and receiving coils, the circuit configuration, the input source of the front end of the transmitting coil, and the input impedance of the rear end of receiving coil. However, both circuit and electromagnetic simulations need to be performed to analyze the entire system, which is a difficult task. In order to overcome this difficulty, a method using an equivalent circuit model is proposed and verified through experiments. Moreover, the worst exposure condition to a magnetic field was examined by considering three variables: the charging mode, the state of charge, and the alignment and misalignment between the transmitting and receiving coils. Accordingly, the strongest magnetic field was created in the constant current mode in the fully charged state with misalignment. For example, the magnetic field strength in the case of 80% state of charge and misalignment was 1.397 times greater than in the case of 20% state of charge and alignment at a point 10 mm from the transmission pad. Finally, the induced electric fields and induced current densities were calculated by using a Japanese adult male whole-body voxel human model, and the results were compared with the values recommended by international guidelines to ascertain their compliance.
format Online
Article
Text
id pubmed-7428189
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-74281892020-08-20 Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry Park, SangWook PLoS One Research Article Accurate dosimetry for a real wireless power transfer system (WPT) using electromagnetic resonance and electromagnetic induction requires an accurate description of the field formed by the system. In particular, the electromagnetic field depends on factors such as the construction of the transmitting and receiving coils, the circuit configuration, the input source of the front end of the transmitting coil, and the input impedance of the rear end of receiving coil. However, both circuit and electromagnetic simulations need to be performed to analyze the entire system, which is a difficult task. In order to overcome this difficulty, a method using an equivalent circuit model is proposed and verified through experiments. Moreover, the worst exposure condition to a magnetic field was examined by considering three variables: the charging mode, the state of charge, and the alignment and misalignment between the transmitting and receiving coils. Accordingly, the strongest magnetic field was created in the constant current mode in the fully charged state with misalignment. For example, the magnetic field strength in the case of 80% state of charge and misalignment was 1.397 times greater than in the case of 20% state of charge and alignment at a point 10 mm from the transmission pad. Finally, the induced electric fields and induced current densities were calculated by using a Japanese adult male whole-body voxel human model, and the results were compared with the values recommended by international guidelines to ascertain their compliance. Public Library of Science 2020-08-14 /pmc/articles/PMC7428189/ /pubmed/32797050 http://dx.doi.org/10.1371/journal.pone.0236929 Text en © 2020 SangWook Park http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Park, SangWook
Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title_full Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title_fullStr Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title_full_unstemmed Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title_short Investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
title_sort investigating human exposure to a practical wireless power transfer system using and the effect about key parameters of dosimetry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7428189/
https://www.ncbi.nlm.nih.gov/pubmed/32797050
http://dx.doi.org/10.1371/journal.pone.0236929
work_keys_str_mv AT parksangwook investigatinghumanexposuretoapracticalwirelesspowertransfersystemusingandtheeffectaboutkeyparametersofdosimetry