Cargando…

Late Outcomes of Valve Repair Versus Replacement in Isolated and Concomitant Tricuspid Valve Surgery: A Nationwide Cohort Study

BACKGROUND: Surgery for tricuspid valve (TV) diseases is associated with poor prognosis, but few studies have described the long‐term outcomes by comparing TV repair and replacement in isolated and concomitant TV surgeries separately. METHODS AND RESULTS: Between 2000 and 2013, adult patients who un...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Wang‐Kin, Chen, Shao‐Wei, Chou, An‐Hsun, Lee, Hsiu‐An, Cheng, Yu‐Ting, Tsai, Feng‐Chun, Lee, Kuang‐Tso, Wu, Victor Chien‐Chia, Wang, Chun‐Li, Chang, Shang‐Hung, Chu, Pao‐Hsien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7428522/
https://www.ncbi.nlm.nih.gov/pubmed/32301369
http://dx.doi.org/10.1161/JAHA.119.015637
Descripción
Sumario:BACKGROUND: Surgery for tricuspid valve (TV) diseases is associated with poor prognosis, but few studies have described the long‐term outcomes by comparing TV repair and replacement in isolated and concomitant TV surgeries separately. METHODS AND RESULTS: Between 2000 and 2013, adult patients who underwent TV repair or replacement surgeries were identified from the Taiwan National Health Insurance Research Database. Outcomes of interest included all‐cause mortality, composite outcome, and readmission attributable to any cause. Inverse probability of treatment weighting was used to reduce confounding effects. A total of 2644 patients with a mean follow‐up of 4.9 years were included. Of them, 12.6% and 87.4% underwent isolated and concomitant TV surgery, respectively. The in‐hospital mortality rates for isolated and concomitant TV surgery were 8.7% and 8.6%, respectively, whereas all‐cause mortality rates were 41.7% and 36.8%, respectively. Compared with TV replacement, TV repair demonstrated significantly lower risks of all‐cause mortality (concomitant: hazard ratio [HR], 0.76; 95% CI, 0.59–0.99), composite outcome (isolated: subdistribution HR, 0.55; 95% CI, 0.35–0.89; concomitant: subdistribution HR, 0.63; 95% CI, 0.46–0.86), and readmission (isolated: subdistribution HR, 0.64; 95% CI, 0.46–0.91; concomitant: subdistribution HR, 0.72; 95% CI, 0.60–0.86), except insignificant difference in all‐cause mortality in isolated surgery. CONCLUSIONS: Compared with replacement, TV repair is associated with better short‐ and long‐term outcomes in both isolated and concomitant TV surgery. However, further prospective clinical trials are warranted.