A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study
BACKGROUND: Smartphone apps for heart rate variability (HRV) measurement have been extensively developed in the last decade. However, ultra–short-term HRV recordings taken by wearable devices have not been examined. OBJECTIVE: The aims of this study were the following: (1) to compare the validity an...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7428904/ https://www.ncbi.nlm.nih.gov/pubmed/32735219 http://dx.doi.org/10.2196/18761 |
_version_ | 1783571174214598656 |
---|---|
author | Chen, Yung-Sheng Lu, Wan-An Pagaduan, Jeffrey C Kuo, Cheng-Deng |
author_facet | Chen, Yung-Sheng Lu, Wan-An Pagaduan, Jeffrey C Kuo, Cheng-Deng |
author_sort | Chen, Yung-Sheng |
collection | PubMed |
description | BACKGROUND: Smartphone apps for heart rate variability (HRV) measurement have been extensively developed in the last decade. However, ultra–short-term HRV recordings taken by wearable devices have not been examined. OBJECTIVE: The aims of this study were the following: (1) to compare the validity and reliability of ultra–short-term and short-term HRV time-domain and frequency-domain variables in a novel smartphone app, Pulse Express Pro (PEP), and (2) to determine the agreement of HRV assessments between an electrocardiogram (ECG) and PEP. METHODS: In total, 60 healthy adults were recruited to participate in this study (mean age 22.3 years [SD 3.0 years], mean height 168.4 cm [SD 8.0 cm], mean body weight 64.2 kg [SD 11.5 kg]). A 5-minute resting HRV measurement was recorded via ECG and PEP in a sitting position. Standard deviation of normal R-R interval (SDNN), root mean square of successive R-R interval (RMSSD), proportion of NN50 divided by the total number of RR intervals (pNN50), normalized very-low–frequency power (nVLF), normalized low-frequency power (nLF), and normalized high-frequency power (nHF) were analyzed within 9 time segments of HRV recordings: 0-1 minute, 1-2 minutes, 2-3 minutes, 3-4 minutes, 4-5 minutes, 0-2 minutes, 0-3 minutes, 0-4 minutes, and 0-5 minutes (standard). Standardized differences (ES), intraclass correlation coefficients (ICC), and the Spearman product-moment correlation were used to compare the validity and reliability of each time segment to the standard measurement (0-5 minutes). Limits of agreement were assessed by using Bland-Altman plot analysis. RESULTS: Compared to standard measures in both ECG and PEP, pNN50, SDNN, and RMSSD variables showed trivial ES (<0.2) and very large to nearly perfect ICC and Spearman correlation coefficient values in all time segments (>0.8). The nVLF, nLF, and nHF demonstrated a variation of ES (from trivial to small effects, 0.01-0.40), ICC (from moderate to nearly perfect, 0.39-0.96), and Spearman correlation coefficient values (from moderate to nearly perfect, 0.40-0.96). Furthermore, the Bland-Altman plots showed relatively narrow values of mean difference between the ECG and PEP after consecutive 1-minute recordings for SDNN, RMSSD, and pNN50. Acceptable limits of agreement were found after consecutive 3-minute recordings for nLF and nHF. CONCLUSIONS: Using the PEP app to facilitate a 1-minute ultra–short-term recording is suggested for time-domain HRV indices (SDNN, RMSSD, and pNN50) to interpret autonomic functions during stabilization. When using frequency-domain HRV indices (nLF and nHF) via the PEP app, a recording of at least 3 minutes is needed for accurate measurement. |
format | Online Article Text |
id | pubmed-7428904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-74289042020-08-24 A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study Chen, Yung-Sheng Lu, Wan-An Pagaduan, Jeffrey C Kuo, Cheng-Deng JMIR Mhealth Uhealth Original Paper BACKGROUND: Smartphone apps for heart rate variability (HRV) measurement have been extensively developed in the last decade. However, ultra–short-term HRV recordings taken by wearable devices have not been examined. OBJECTIVE: The aims of this study were the following: (1) to compare the validity and reliability of ultra–short-term and short-term HRV time-domain and frequency-domain variables in a novel smartphone app, Pulse Express Pro (PEP), and (2) to determine the agreement of HRV assessments between an electrocardiogram (ECG) and PEP. METHODS: In total, 60 healthy adults were recruited to participate in this study (mean age 22.3 years [SD 3.0 years], mean height 168.4 cm [SD 8.0 cm], mean body weight 64.2 kg [SD 11.5 kg]). A 5-minute resting HRV measurement was recorded via ECG and PEP in a sitting position. Standard deviation of normal R-R interval (SDNN), root mean square of successive R-R interval (RMSSD), proportion of NN50 divided by the total number of RR intervals (pNN50), normalized very-low–frequency power (nVLF), normalized low-frequency power (nLF), and normalized high-frequency power (nHF) were analyzed within 9 time segments of HRV recordings: 0-1 minute, 1-2 minutes, 2-3 minutes, 3-4 minutes, 4-5 minutes, 0-2 minutes, 0-3 minutes, 0-4 minutes, and 0-5 minutes (standard). Standardized differences (ES), intraclass correlation coefficients (ICC), and the Spearman product-moment correlation were used to compare the validity and reliability of each time segment to the standard measurement (0-5 minutes). Limits of agreement were assessed by using Bland-Altman plot analysis. RESULTS: Compared to standard measures in both ECG and PEP, pNN50, SDNN, and RMSSD variables showed trivial ES (<0.2) and very large to nearly perfect ICC and Spearman correlation coefficient values in all time segments (>0.8). The nVLF, nLF, and nHF demonstrated a variation of ES (from trivial to small effects, 0.01-0.40), ICC (from moderate to nearly perfect, 0.39-0.96), and Spearman correlation coefficient values (from moderate to nearly perfect, 0.40-0.96). Furthermore, the Bland-Altman plots showed relatively narrow values of mean difference between the ECG and PEP after consecutive 1-minute recordings for SDNN, RMSSD, and pNN50. Acceptable limits of agreement were found after consecutive 3-minute recordings for nLF and nHF. CONCLUSIONS: Using the PEP app to facilitate a 1-minute ultra–short-term recording is suggested for time-domain HRV indices (SDNN, RMSSD, and pNN50) to interpret autonomic functions during stabilization. When using frequency-domain HRV indices (nLF and nHF) via the PEP app, a recording of at least 3 minutes is needed for accurate measurement. JMIR Publications 2020-07-31 /pmc/articles/PMC7428904/ /pubmed/32735219 http://dx.doi.org/10.2196/18761 Text en ©Yung-Sheng Chen, Wan-An Lu, Jeffrey C Pagaduan, Cheng-Deng Kuo. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 31.07.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Chen, Yung-Sheng Lu, Wan-An Pagaduan, Jeffrey C Kuo, Cheng-Deng A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title | A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title_full | A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title_fullStr | A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title_full_unstemmed | A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title_short | A Novel Smartphone App for the Measurement of Ultra–Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study |
title_sort | novel smartphone app for the measurement of ultra–short-term and short-term heart rate variability: validity and reliability study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7428904/ https://www.ncbi.nlm.nih.gov/pubmed/32735219 http://dx.doi.org/10.2196/18761 |
work_keys_str_mv | AT chenyungsheng anovelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT luwanan anovelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT pagaduanjeffreyc anovelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT kuochengdeng anovelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT chenyungsheng novelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT luwanan novelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT pagaduanjeffreyc novelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy AT kuochengdeng novelsmartphoneappforthemeasurementofultrashorttermandshorttermheartratevariabilityvalidityandreliabilitystudy |