Cargando…

Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine

BACKGROUND: Maintaining cervical immobilization is essential during tracheal intubation in patients with unstable cervical spines. When using the Macintosh laryngoscope for intubation in patients with cervical immobilization, substantial neck extension is required for visualization of the glottis. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Paik, Hyesun, Park, Hee-Pyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7429469/
https://www.ncbi.nlm.nih.gov/pubmed/32799791
http://dx.doi.org/10.1186/s12871-020-01118-3
_version_ 1783571269279547392
author Paik, Hyesun
Park, Hee-Pyoung
author_facet Paik, Hyesun
Park, Hee-Pyoung
author_sort Paik, Hyesun
collection PubMed
description BACKGROUND: Maintaining cervical immobilization is essential during tracheal intubation in patients with unstable cervical spines. When using the Macintosh laryngoscope for intubation in patients with cervical immobilization, substantial neck extension is required for visualization of the glottis. However, the C-MAC D-Blade videolaryngoscope may require less neck extension due to its acute angulation. We hypothesized that C-MAC D-Blade videolaryngoscopic intubation would result in less cervical spine movement than Macintosh laryngoscopic intubation. We compared the effects of C-MAC D-Blade videolaryngoscopic intubation and Macintosh laryngoscopic intubation in terms of cervical spine motion during intubation in patients with simulated cervical immobilization. METHODS: In this randomized crossover study, the cervical spine angle was measured at the occiput–C1, C1–C2, and C2–C5 segments before and during tracheal intubation with either a C-MAC D-Blade videolaryngoscope or Macintosh laryngoscope in 20 patients, with application of a neck collar for simulated cervical immobilization. Cervical spine motion was defined as the change in angle measured before and during tracheal intubation. RESULTS: The cervical spine motion at the occiput–C1 segment was measured at 12.1 ± 4.2° and 6.8 ± 5.0° during Macintosh laryngoscopic and C-MAC D-blade videolaryngoscopic intubation, respectively, corresponding to a 44% reduction in cervical spine motion when using the latter device (mean difference, − 5.3; 98.33% CI: − 8.8 to − 1.8; p = 0.001). However, there was no significant difference between the two intubation devices at the C1–C2 segment (− 0.6; 98.33% CI: − 3.4 to 2.2; p = 0.639) or C2–C5 segment (0.2; 98.33% CI: − 6.0 to 6.4; p = 0.929). CONCLUSIONS: The C-MAC D-Blade videolaryngoscope causes less upper cervical spine motion than the Macintosh laryngoscope during tracheal intubation of patients with simulated cervical immobilization. TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov on June 26, 2018 (NCT03567902).
format Online
Article
Text
id pubmed-7429469
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-74294692020-08-18 Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine Paik, Hyesun Park, Hee-Pyoung BMC Anesthesiol Research Article BACKGROUND: Maintaining cervical immobilization is essential during tracheal intubation in patients with unstable cervical spines. When using the Macintosh laryngoscope for intubation in patients with cervical immobilization, substantial neck extension is required for visualization of the glottis. However, the C-MAC D-Blade videolaryngoscope may require less neck extension due to its acute angulation. We hypothesized that C-MAC D-Blade videolaryngoscopic intubation would result in less cervical spine movement than Macintosh laryngoscopic intubation. We compared the effects of C-MAC D-Blade videolaryngoscopic intubation and Macintosh laryngoscopic intubation in terms of cervical spine motion during intubation in patients with simulated cervical immobilization. METHODS: In this randomized crossover study, the cervical spine angle was measured at the occiput–C1, C1–C2, and C2–C5 segments before and during tracheal intubation with either a C-MAC D-Blade videolaryngoscope or Macintosh laryngoscope in 20 patients, with application of a neck collar for simulated cervical immobilization. Cervical spine motion was defined as the change in angle measured before and during tracheal intubation. RESULTS: The cervical spine motion at the occiput–C1 segment was measured at 12.1 ± 4.2° and 6.8 ± 5.0° during Macintosh laryngoscopic and C-MAC D-blade videolaryngoscopic intubation, respectively, corresponding to a 44% reduction in cervical spine motion when using the latter device (mean difference, − 5.3; 98.33% CI: − 8.8 to − 1.8; p = 0.001). However, there was no significant difference between the two intubation devices at the C1–C2 segment (− 0.6; 98.33% CI: − 3.4 to 2.2; p = 0.639) or C2–C5 segment (0.2; 98.33% CI: − 6.0 to 6.4; p = 0.929). CONCLUSIONS: The C-MAC D-Blade videolaryngoscope causes less upper cervical spine motion than the Macintosh laryngoscope during tracheal intubation of patients with simulated cervical immobilization. TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov on June 26, 2018 (NCT03567902). BioMed Central 2020-08-15 /pmc/articles/PMC7429469/ /pubmed/32799791 http://dx.doi.org/10.1186/s12871-020-01118-3 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Paik, Hyesun
Park, Hee-Pyoung
Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title_full Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title_fullStr Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title_full_unstemmed Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title_short Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
title_sort randomized crossover trial comparing cervical spine motion during tracheal intubation with a macintosh laryngoscope versus a c-mac d-blade videolaryngoscope in a simulated immobilized cervical spine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7429469/
https://www.ncbi.nlm.nih.gov/pubmed/32799791
http://dx.doi.org/10.1186/s12871-020-01118-3
work_keys_str_mv AT paikhyesun randomizedcrossovertrialcomparingcervicalspinemotionduringtrachealintubationwithamacintoshlaryngoscopeversusacmacdbladevideolaryngoscopeinasimulatedimmobilizedcervicalspine
AT parkheepyoung randomizedcrossovertrialcomparingcervicalspinemotionduringtrachealintubationwithamacintoshlaryngoscopeversusacmacdbladevideolaryngoscopeinasimulatedimmobilizedcervicalspine