Cargando…

Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements

Air quality information is scarce in low‐ and middle‐income countries. This study describes the application of moderate cost approaches that can provide spatial and temporal information on concentrations of particulate matter (PM) needed to assess community and occupational exposures. We evaluated P...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwarteng, Lawrencia, Baiden, Emmanuel Acquah, Fobil, Julius, Arko‐Mensah, John, Robins, Thomas, Batterman, Stuart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7431652/
https://www.ncbi.nlm.nih.gov/pubmed/32832821
http://dx.doi.org/10.1029/2020GH000247
_version_ 1783571627925045248
author Kwarteng, Lawrencia
Baiden, Emmanuel Acquah
Fobil, Julius
Arko‐Mensah, John
Robins, Thomas
Batterman, Stuart
author_facet Kwarteng, Lawrencia
Baiden, Emmanuel Acquah
Fobil, Julius
Arko‐Mensah, John
Robins, Thomas
Batterman, Stuart
author_sort Kwarteng, Lawrencia
collection PubMed
description Air quality information is scarce in low‐ and middle‐income countries. This study describes the application of moderate cost approaches that can provide spatial and temporal information on concentrations of particulate matter (PM) needed to assess community and occupational exposures. We evaluated PM levels at the Agbogbloshie e‐waste and scrap yard site in Accra, Ghana, and at upwind and downwind locations, obtaining both optical and gravimetric measurements, local meteorological data and satellite aerosol optical depth. Due to overload issues, the gravimetric 24‐hr samplers were modified for periodic sampling and some optical data were screened for quality assurance. Exceptionally high concentrations (e.g., 1‐hr average PM(10) exceeding 2000 μg/m(3)) were sometimes encountered near combustion sources, including open fires at the e‐waste site and spoil piles. 24‐hr PM(2.5) levels averaged 31, 88 and 57 μg/m(3) at upwind, e‐waste and downwind sites, respectively, and PM(10) averaged 145, 214 and 190 μg/m(3), considerably exceeding air quality standards. Upwind levels likely reflected biomass burning that is prevalent in the surrounding informal settlements; levels at the e‐waste and downwind sites also reflected contributions from biomass combustion and traffic. The highest PM levels occurred in evenings, influenced by diurnal changes in emission rates, atmospheric dispersion and wind direction shifts. We demonstrate that moderate cost instrumentation, with some modifications, appropriate data cleaning protocols, and attention to understanding local sources and background levels, can be used to characterize spatial and temporal variation in PM levels in urban and industrial areas.
format Online
Article
Text
id pubmed-7431652
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-74316522020-08-20 Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements Kwarteng, Lawrencia Baiden, Emmanuel Acquah Fobil, Julius Arko‐Mensah, John Robins, Thomas Batterman, Stuart Geohealth Research Articles Air quality information is scarce in low‐ and middle‐income countries. This study describes the application of moderate cost approaches that can provide spatial and temporal information on concentrations of particulate matter (PM) needed to assess community and occupational exposures. We evaluated PM levels at the Agbogbloshie e‐waste and scrap yard site in Accra, Ghana, and at upwind and downwind locations, obtaining both optical and gravimetric measurements, local meteorological data and satellite aerosol optical depth. Due to overload issues, the gravimetric 24‐hr samplers were modified for periodic sampling and some optical data were screened for quality assurance. Exceptionally high concentrations (e.g., 1‐hr average PM(10) exceeding 2000 μg/m(3)) were sometimes encountered near combustion sources, including open fires at the e‐waste site and spoil piles. 24‐hr PM(2.5) levels averaged 31, 88 and 57 μg/m(3) at upwind, e‐waste and downwind sites, respectively, and PM(10) averaged 145, 214 and 190 μg/m(3), considerably exceeding air quality standards. Upwind levels likely reflected biomass burning that is prevalent in the surrounding informal settlements; levels at the e‐waste and downwind sites also reflected contributions from biomass combustion and traffic. The highest PM levels occurred in evenings, influenced by diurnal changes in emission rates, atmospheric dispersion and wind direction shifts. We demonstrate that moderate cost instrumentation, with some modifications, appropriate data cleaning protocols, and attention to understanding local sources and background levels, can be used to characterize spatial and temporal variation in PM levels in urban and industrial areas. John Wiley and Sons Inc. 2020-08-01 /pmc/articles/PMC7431652/ /pubmed/32832821 http://dx.doi.org/10.1029/2020GH000247 Text en ©2020. The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Kwarteng, Lawrencia
Baiden, Emmanuel Acquah
Fobil, Julius
Arko‐Mensah, John
Robins, Thomas
Batterman, Stuart
Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title_full Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title_fullStr Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title_full_unstemmed Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title_short Air Quality Impacts at an E‐Waste Site in Ghana Using Flexible, Moderate‐Cost and Quality‐Assured Measurements
title_sort air quality impacts at an e‐waste site in ghana using flexible, moderate‐cost and quality‐assured measurements
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7431652/
https://www.ncbi.nlm.nih.gov/pubmed/32832821
http://dx.doi.org/10.1029/2020GH000247
work_keys_str_mv AT kwartenglawrencia airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements
AT baidenemmanuelacquah airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements
AT fobiljulius airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements
AT arkomensahjohn airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements
AT robinsthomas airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements
AT battermanstuart airqualityimpactsatanewastesiteinghanausingflexiblemoderatecostandqualityassuredmeasurements