Cargando…
Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task
Cardiorespiratory (e.g., heart rate and breathing rate) and thermoregulatory (e.g., local skin temperature and electrodermal activity) responses are controlled by the sympathetic nervous system. To cope with increased physical workload, the sympathetic system upregulates its activity to generate gre...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432684/ https://www.ncbi.nlm.nih.gov/pubmed/32731366 http://dx.doi.org/10.3390/ijerph17155418 |
_version_ | 1783571851134369792 |
---|---|
author | Anwer, Shahnawaz Li, Heng Antwi-Afari, Maxwell Fordjour Umer, Waleed Wong, Arnold Y. L. |
author_facet | Anwer, Shahnawaz Li, Heng Antwi-Afari, Maxwell Fordjour Umer, Waleed Wong, Arnold Y. L. |
author_sort | Anwer, Shahnawaz |
collection | PubMed |
description | Cardiorespiratory (e.g., heart rate and breathing rate) and thermoregulatory (e.g., local skin temperature and electrodermal activity) responses are controlled by the sympathetic nervous system. To cope with increased physical workload, the sympathetic system upregulates its activity to generate greater sympathetic responses (i.e., increased heart rate and respiratory rate). Therefore, physiological measures may have the potential to evaluate changes in physical condition (including fatigue) during functional tasks. This study aimed to quantify physical fatigue using wearable cardiorespiratory and thermoregulatory sensors during a simulated construction task. Twenty-five healthy individuals (mean age, 31.8 ± 1.8 years) were recruited. Participants were instructed to perform 30 min of a simulated manual material handling task in a laboratory. The experimental setup comprised a station A, a 10-metre walking platform, and a station B. Each participant was asked to pick up a 15 kg ergonomically-designed wooden box from station A and then carried it along the platform and dropped it at station B. The task was repeated from B to A and then A to B until the participants perceived a fatigue level > 15 out of 20 on the Borg-20 scale. Heart rate, breathing rate, local skin temperature, and electrodermal activity at the wrist were measured by wearable sensors and the perceived physical fatigue was assessed using the Borg-20 scale at baseline, 15 min, and 30 min from the baseline. There were significant increases in the heart rate (mean changes: 50 ± 13.3 beats/min), breathing rate (mean changes: 9.8 ± 4.1 breaths), local skin temperature (mean changes: 3.4 ± 1.9 °C), electrodermal activity at the right wrist (mean changes: 7.1 ± 3.8 µS/cm), and subjective physical fatigue (mean changes: 8.8 ± 0.6 levels) at the end of the simulated construction task (p < 0.05). Heart rate and breathing rate at 15 and 30 min were significantly correlated with the corresponding subjective Borg scores (p < 0.01). Local skin temperature at 30 min was significantly correlated with the corresponding Borg scores (p < 0.05). However, electrodermal activity at the right wrist was not associated with Borg scores at any time points. The results implied cardiorespiratory parameters and local skin temperature were good surrogates for measuring physical fatigue. Conversely, electrodermal activity at the right wrist was unrelated to physical fatigue. Future field studies should investigate the sensitivity of various cardiorespiratory and thermoregulatory parameters for real time physical fatigue monitoring in construction sites. |
format | Online Article Text |
id | pubmed-7432684 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74326842020-08-27 Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task Anwer, Shahnawaz Li, Heng Antwi-Afari, Maxwell Fordjour Umer, Waleed Wong, Arnold Y. L. Int J Environ Res Public Health Article Cardiorespiratory (e.g., heart rate and breathing rate) and thermoregulatory (e.g., local skin temperature and electrodermal activity) responses are controlled by the sympathetic nervous system. To cope with increased physical workload, the sympathetic system upregulates its activity to generate greater sympathetic responses (i.e., increased heart rate and respiratory rate). Therefore, physiological measures may have the potential to evaluate changes in physical condition (including fatigue) during functional tasks. This study aimed to quantify physical fatigue using wearable cardiorespiratory and thermoregulatory sensors during a simulated construction task. Twenty-five healthy individuals (mean age, 31.8 ± 1.8 years) were recruited. Participants were instructed to perform 30 min of a simulated manual material handling task in a laboratory. The experimental setup comprised a station A, a 10-metre walking platform, and a station B. Each participant was asked to pick up a 15 kg ergonomically-designed wooden box from station A and then carried it along the platform and dropped it at station B. The task was repeated from B to A and then A to B until the participants perceived a fatigue level > 15 out of 20 on the Borg-20 scale. Heart rate, breathing rate, local skin temperature, and electrodermal activity at the wrist were measured by wearable sensors and the perceived physical fatigue was assessed using the Borg-20 scale at baseline, 15 min, and 30 min from the baseline. There were significant increases in the heart rate (mean changes: 50 ± 13.3 beats/min), breathing rate (mean changes: 9.8 ± 4.1 breaths), local skin temperature (mean changes: 3.4 ± 1.9 °C), electrodermal activity at the right wrist (mean changes: 7.1 ± 3.8 µS/cm), and subjective physical fatigue (mean changes: 8.8 ± 0.6 levels) at the end of the simulated construction task (p < 0.05). Heart rate and breathing rate at 15 and 30 min were significantly correlated with the corresponding subjective Borg scores (p < 0.01). Local skin temperature at 30 min was significantly correlated with the corresponding Borg scores (p < 0.05). However, electrodermal activity at the right wrist was not associated with Borg scores at any time points. The results implied cardiorespiratory parameters and local skin temperature were good surrogates for measuring physical fatigue. Conversely, electrodermal activity at the right wrist was unrelated to physical fatigue. Future field studies should investigate the sensitivity of various cardiorespiratory and thermoregulatory parameters for real time physical fatigue monitoring in construction sites. MDPI 2020-07-28 2020-08 /pmc/articles/PMC7432684/ /pubmed/32731366 http://dx.doi.org/10.3390/ijerph17155418 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Anwer, Shahnawaz Li, Heng Antwi-Afari, Maxwell Fordjour Umer, Waleed Wong, Arnold Y. L. Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title | Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title_full | Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title_fullStr | Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title_full_unstemmed | Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title_short | Cardiorespiratory and Thermoregulatory Parameters Are Good Surrogates for Measuring Physical Fatigue during a Simulated Construction Task |
title_sort | cardiorespiratory and thermoregulatory parameters are good surrogates for measuring physical fatigue during a simulated construction task |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432684/ https://www.ncbi.nlm.nih.gov/pubmed/32731366 http://dx.doi.org/10.3390/ijerph17155418 |
work_keys_str_mv | AT anwershahnawaz cardiorespiratoryandthermoregulatoryparametersaregoodsurrogatesformeasuringphysicalfatigueduringasimulatedconstructiontask AT liheng cardiorespiratoryandthermoregulatoryparametersaregoodsurrogatesformeasuringphysicalfatigueduringasimulatedconstructiontask AT antwiafarimaxwellfordjour cardiorespiratoryandthermoregulatoryparametersaregoodsurrogatesformeasuringphysicalfatigueduringasimulatedconstructiontask AT umerwaleed cardiorespiratoryandthermoregulatoryparametersaregoodsurrogatesformeasuringphysicalfatigueduringasimulatedconstructiontask AT wongarnoldyl cardiorespiratoryandthermoregulatoryparametersaregoodsurrogatesformeasuringphysicalfatigueduringasimulatedconstructiontask |