Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods

Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However,...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Hyungyu, Park, Seonghyun, Seo, Janghoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432819/
https://www.ncbi.nlm.nih.gov/pubmed/32752211
http://dx.doi.org/10.3390/ijerph17155561
_version_ 1783571882268688384
author Park, Hyungyu
Park, Seonghyun
Seo, Janghoo
author_facet Park, Hyungyu
Park, Seonghyun
Seo, Janghoo
author_sort Park, Hyungyu
collection PubMed
description Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m(3) compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m(3) in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants.
format Online
Article
Text
id pubmed-7432819
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74328192020-08-27 Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods Park, Hyungyu Park, Seonghyun Seo, Janghoo Int J Environ Res Public Health Article Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m(3) compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m(3) in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants. MDPI 2020-08-01 2020-08 /pmc/articles/PMC7432819/ /pubmed/32752211 http://dx.doi.org/10.3390/ijerph17155561 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Hyungyu
Park, Seonghyun
Seo, Janghoo
Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title_full Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title_fullStr Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title_full_unstemmed Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title_short Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
title_sort evaluation on air purifier’s performance in reducing the concentration of fine particulate matter for occupants according to its operation methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432819/
https://www.ncbi.nlm.nih.gov/pubmed/32752211
http://dx.doi.org/10.3390/ijerph17155561
work_keys_str_mv AT parkhyungyu evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods
AT parkseonghyun evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods
AT seojanghoo evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods