Cargando…
Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods
Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432819/ https://www.ncbi.nlm.nih.gov/pubmed/32752211 http://dx.doi.org/10.3390/ijerph17155561 |
_version_ | 1783571882268688384 |
---|---|
author | Park, Hyungyu Park, Seonghyun Seo, Janghoo |
author_facet | Park, Hyungyu Park, Seonghyun Seo, Janghoo |
author_sort | Park, Hyungyu |
collection | PubMed |
description | Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m(3) compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m(3) in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants. |
format | Online Article Text |
id | pubmed-7432819 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74328192020-08-27 Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods Park, Hyungyu Park, Seonghyun Seo, Janghoo Int J Environ Res Public Health Article Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m(3) compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m(3) in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants. MDPI 2020-08-01 2020-08 /pmc/articles/PMC7432819/ /pubmed/32752211 http://dx.doi.org/10.3390/ijerph17155561 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Hyungyu Park, Seonghyun Seo, Janghoo Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title | Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title_full | Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title_fullStr | Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title_full_unstemmed | Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title_short | Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods |
title_sort | evaluation on air purifier’s performance in reducing the concentration of fine particulate matter for occupants according to its operation methods |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7432819/ https://www.ncbi.nlm.nih.gov/pubmed/32752211 http://dx.doi.org/10.3390/ijerph17155561 |
work_keys_str_mv | AT parkhyungyu evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods AT parkseonghyun evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods AT seojanghoo evaluationonairpurifiersperformanceinreducingtheconcentrationoffineparticulatematterforoccupantsaccordingtoitsoperationmethods |