Cargando…

Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study

BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with...

Descripción completa

Detalles Bibliográficos
Autores principales: Hsu, Chih-Chao, Huang, Yin-Kai, Kang, Jiunn-Horng, Ko, Yi-Feng, Liu, Chia-Wei, Jaw, Fu-Shan, Chen, Shih-Ching
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433152/
https://www.ncbi.nlm.nih.gov/pubmed/32811516
http://dx.doi.org/10.1186/s12984-020-00734-x
_version_ 1783571949145817088
author Hsu, Chih-Chao
Huang, Yin-Kai
Kang, Jiunn-Horng
Ko, Yi-Feng
Liu, Chia-Wei
Jaw, Fu-Shan
Chen, Shih-Ching
author_facet Hsu, Chih-Chao
Huang, Yin-Kai
Kang, Jiunn-Horng
Ko, Yi-Feng
Liu, Chia-Wei
Jaw, Fu-Shan
Chen, Shih-Ching
author_sort Hsu, Chih-Chao
collection PubMed
description BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with and without dynamic control and conventional anterior-type AFO or no AFO. METHODS: Gait parameters were measured using the RehaWatch® system in seven individuals with hemiplegia (mean 51.14 years). The parameters were compared across four conditions: no AFO, conventional anterior AFO, IT-AFO without dynamic control, and IT-AFO with dynamic control, with three trials of a 10-m walk test for each. RESULTS: The dorsiflexion angle increased during the swing phase when the IT-AFO was worn, and it was larger with dynamic control. These data can confirm drop foot improvement; however, the difference between the parameters with- and without-AFO control conditions was not significant in the swing phase. The IT-AFO with or without dynamic control enhanced the loading response to a greater extent between the hemiparetic and unaffected lower limbs than conventional AFO or no AFO. The duration of the stance phase on the hemiparetic lower limb was also longer when using IT-AFO with and without dynamic control than that when using conventional AFO, which improved asymmetry. User comfort and satisfaction was greater with IT-AFO than with the other conditions. CONCLUSIONS: The IT-AFO with dynamic control improved gait pattern and weight shifting to the hemiparetic lower limb, reducing gait asymmetry. The difference with and without dynamic control of IT-AFO is not statistically significant, and it is limited by sample size. However, this study shows the potential of IT-AFO in applying positive motion feedback with gait training. TRIAL REGISTRATION: Taipei Medical University-Joint Institutional Review Board. N201510010. Registered 12 February 2015. http://ohr.tmu.edu.tw/main.php.
format Online
Article
Text
id pubmed-7433152
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-74331522020-08-19 Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study Hsu, Chih-Chao Huang, Yin-Kai Kang, Jiunn-Horng Ko, Yi-Feng Liu, Chia-Wei Jaw, Fu-Shan Chen, Shih-Ching J Neuroeng Rehabil Research BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with and without dynamic control and conventional anterior-type AFO or no AFO. METHODS: Gait parameters were measured using the RehaWatch® system in seven individuals with hemiplegia (mean 51.14 years). The parameters were compared across four conditions: no AFO, conventional anterior AFO, IT-AFO without dynamic control, and IT-AFO with dynamic control, with three trials of a 10-m walk test for each. RESULTS: The dorsiflexion angle increased during the swing phase when the IT-AFO was worn, and it was larger with dynamic control. These data can confirm drop foot improvement; however, the difference between the parameters with- and without-AFO control conditions was not significant in the swing phase. The IT-AFO with or without dynamic control enhanced the loading response to a greater extent between the hemiparetic and unaffected lower limbs than conventional AFO or no AFO. The duration of the stance phase on the hemiparetic lower limb was also longer when using IT-AFO with and without dynamic control than that when using conventional AFO, which improved asymmetry. User comfort and satisfaction was greater with IT-AFO than with the other conditions. CONCLUSIONS: The IT-AFO with dynamic control improved gait pattern and weight shifting to the hemiparetic lower limb, reducing gait asymmetry. The difference with and without dynamic control of IT-AFO is not statistically significant, and it is limited by sample size. However, this study shows the potential of IT-AFO in applying positive motion feedback with gait training. TRIAL REGISTRATION: Taipei Medical University-Joint Institutional Review Board. N201510010. Registered 12 February 2015. http://ohr.tmu.edu.tw/main.php. BioMed Central 2020-08-18 /pmc/articles/PMC7433152/ /pubmed/32811516 http://dx.doi.org/10.1186/s12984-020-00734-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Hsu, Chih-Chao
Huang, Yin-Kai
Kang, Jiunn-Horng
Ko, Yi-Feng
Liu, Chia-Wei
Jaw, Fu-Shan
Chen, Shih-Ching
Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title_full Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title_fullStr Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title_full_unstemmed Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title_short Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
title_sort novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433152/
https://www.ncbi.nlm.nih.gov/pubmed/32811516
http://dx.doi.org/10.1186/s12984-020-00734-x
work_keys_str_mv AT hsuchihchao noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT huangyinkai noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT kangjiunnhorng noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT koyifeng noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT liuchiawei noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT jawfushan noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy
AT chenshihching noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy