Cargando…
Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study
BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433152/ https://www.ncbi.nlm.nih.gov/pubmed/32811516 http://dx.doi.org/10.1186/s12984-020-00734-x |
_version_ | 1783571949145817088 |
---|---|
author | Hsu, Chih-Chao Huang, Yin-Kai Kang, Jiunn-Horng Ko, Yi-Feng Liu, Chia-Wei Jaw, Fu-Shan Chen, Shih-Ching |
author_facet | Hsu, Chih-Chao Huang, Yin-Kai Kang, Jiunn-Horng Ko, Yi-Feng Liu, Chia-Wei Jaw, Fu-Shan Chen, Shih-Ching |
author_sort | Hsu, Chih-Chao |
collection | PubMed |
description | BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with and without dynamic control and conventional anterior-type AFO or no AFO. METHODS: Gait parameters were measured using the RehaWatch® system in seven individuals with hemiplegia (mean 51.14 years). The parameters were compared across four conditions: no AFO, conventional anterior AFO, IT-AFO without dynamic control, and IT-AFO with dynamic control, with three trials of a 10-m walk test for each. RESULTS: The dorsiflexion angle increased during the swing phase when the IT-AFO was worn, and it was larger with dynamic control. These data can confirm drop foot improvement; however, the difference between the parameters with- and without-AFO control conditions was not significant in the swing phase. The IT-AFO with or without dynamic control enhanced the loading response to a greater extent between the hemiparetic and unaffected lower limbs than conventional AFO or no AFO. The duration of the stance phase on the hemiparetic lower limb was also longer when using IT-AFO with and without dynamic control than that when using conventional AFO, which improved asymmetry. User comfort and satisfaction was greater with IT-AFO than with the other conditions. CONCLUSIONS: The IT-AFO with dynamic control improved gait pattern and weight shifting to the hemiparetic lower limb, reducing gait asymmetry. The difference with and without dynamic control of IT-AFO is not statistically significant, and it is limited by sample size. However, this study shows the potential of IT-AFO in applying positive motion feedback with gait training. TRIAL REGISTRATION: Taipei Medical University-Joint Institutional Review Board. N201510010. Registered 12 February 2015. http://ohr.tmu.edu.tw/main.php. |
format | Online Article Text |
id | pubmed-7433152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-74331522020-08-19 Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study Hsu, Chih-Chao Huang, Yin-Kai Kang, Jiunn-Horng Ko, Yi-Feng Liu, Chia-Wei Jaw, Fu-Shan Chen, Shih-Ching J Neuroeng Rehabil Research BACKGROUND: We designed a novel ankle foot orthosis (AFO), namely, ideal training AFO (IT-AFO), with motion feedback on the hemiparetic lower limb to improve ambulation in individuals with stroke-related hemiplegia. We, therefore sought to compare the kinematic parameters of gait between IT-AFO with and without dynamic control and conventional anterior-type AFO or no AFO. METHODS: Gait parameters were measured using the RehaWatch® system in seven individuals with hemiplegia (mean 51.14 years). The parameters were compared across four conditions: no AFO, conventional anterior AFO, IT-AFO without dynamic control, and IT-AFO with dynamic control, with three trials of a 10-m walk test for each. RESULTS: The dorsiflexion angle increased during the swing phase when the IT-AFO was worn, and it was larger with dynamic control. These data can confirm drop foot improvement; however, the difference between the parameters with- and without-AFO control conditions was not significant in the swing phase. The IT-AFO with or without dynamic control enhanced the loading response to a greater extent between the hemiparetic and unaffected lower limbs than conventional AFO or no AFO. The duration of the stance phase on the hemiparetic lower limb was also longer when using IT-AFO with and without dynamic control than that when using conventional AFO, which improved asymmetry. User comfort and satisfaction was greater with IT-AFO than with the other conditions. CONCLUSIONS: The IT-AFO with dynamic control improved gait pattern and weight shifting to the hemiparetic lower limb, reducing gait asymmetry. The difference with and without dynamic control of IT-AFO is not statistically significant, and it is limited by sample size. However, this study shows the potential of IT-AFO in applying positive motion feedback with gait training. TRIAL REGISTRATION: Taipei Medical University-Joint Institutional Review Board. N201510010. Registered 12 February 2015. http://ohr.tmu.edu.tw/main.php. BioMed Central 2020-08-18 /pmc/articles/PMC7433152/ /pubmed/32811516 http://dx.doi.org/10.1186/s12984-020-00734-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Hsu, Chih-Chao Huang, Yin-Kai Kang, Jiunn-Horng Ko, Yi-Feng Liu, Chia-Wei Jaw, Fu-Shan Chen, Shih-Ching Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title | Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title_full | Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title_fullStr | Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title_full_unstemmed | Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title_short | Novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
title_sort | novel design for a dynamic ankle foot orthosis with motion feedback used for training in patients with hemiplegic gait: a pilot study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433152/ https://www.ncbi.nlm.nih.gov/pubmed/32811516 http://dx.doi.org/10.1186/s12984-020-00734-x |
work_keys_str_mv | AT hsuchihchao noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT huangyinkai noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT kangjiunnhorng noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT koyifeng noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT liuchiawei noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT jawfushan noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy AT chenshihching noveldesignforadynamicanklefootorthosiswithmotionfeedbackusedfortraininginpatientswithhemiplegicgaitapilotstudy |