Cargando…
Reliability and validity of the Chronojump open-source jump mat system
Vertical jump performance is a commonly used test to measure lower-limb muscle power that is carried out with several types of equipment. The aim of this study was to validate an open-source jump mat (Chronojump Boscosystems) against a proprietary jump mat (Globus Ergo Tester). Sixty-three active sp...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Institute of Sport in Warsaw
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433325/ https://www.ncbi.nlm.nih.gov/pubmed/32879547 http://dx.doi.org/10.5114/biolsport.2020.95636 |
_version_ | 1783571982765260800 |
---|---|
author | Pueo, Basilio Penichet-Tomas, Alfonso Jimenez-Olmedo, Jose Manuel |
author_facet | Pueo, Basilio Penichet-Tomas, Alfonso Jimenez-Olmedo, Jose Manuel |
author_sort | Pueo, Basilio |
collection | PubMed |
description | Vertical jump performance is a commonly used test to measure lower-limb muscle power that is carried out with several types of equipment. The aim of this study was to validate an open-source jump mat (Chronojump Boscosystems) against a proprietary jump mat (Globus Ergo Tester). Sixty-three active sportsmen (age 23.3 ± 2.4 years) completed 8 maximal-effort countermovement jumps (CMJ). The heights of the 504 CMJ were measured from the two jump mats simultaneously. Reliability was examined with intra-class correlation coefficients (ICC), paired samples t-tests, coefficient of variation (CV) and Cronbach’s α. Bivariate Pearson’s correlation coefficient (r) was used to examine validity. Effects were evaluated using non-clinical magnitude-based inference. There was almost perfect agreement between instruments (ICC = 0.999−1.000, most likely positive 100/0/0). Paired t-test showed a mean difference of 0.03 ± 0.21 cm (90% CI -0.04 − -0.01) between instruments (most likely trivial 0/100/0). Both instruments showed very good stability (α = 1.00, CV = 4.28±1.95%). The smallest worthwhile change and typical error values were 1.3 and 0.29 cm, respectively and therefore, the signal-to-noise ratio of both instruments was large: 4.5. Finally, almost perfect correlation between instruments was observed (r = 0.999, most likely positive 100/0/0). Chronojump can be regarded as a sensitive instrument to detect changes in jump height performance over the possible noise around the measure. The results supported the open-source jump mat to be a useful, valid and reliable, low-cost testing device to monitor variations in vertical jumping performance. |
format | Online Article Text |
id | pubmed-7433325 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Institute of Sport in Warsaw |
record_format | MEDLINE/PubMed |
spelling | pubmed-74333252020-09-01 Reliability and validity of the Chronojump open-source jump mat system Pueo, Basilio Penichet-Tomas, Alfonso Jimenez-Olmedo, Jose Manuel Biol Sport Original Paper Vertical jump performance is a commonly used test to measure lower-limb muscle power that is carried out with several types of equipment. The aim of this study was to validate an open-source jump mat (Chronojump Boscosystems) against a proprietary jump mat (Globus Ergo Tester). Sixty-three active sportsmen (age 23.3 ± 2.4 years) completed 8 maximal-effort countermovement jumps (CMJ). The heights of the 504 CMJ were measured from the two jump mats simultaneously. Reliability was examined with intra-class correlation coefficients (ICC), paired samples t-tests, coefficient of variation (CV) and Cronbach’s α. Bivariate Pearson’s correlation coefficient (r) was used to examine validity. Effects were evaluated using non-clinical magnitude-based inference. There was almost perfect agreement between instruments (ICC = 0.999−1.000, most likely positive 100/0/0). Paired t-test showed a mean difference of 0.03 ± 0.21 cm (90% CI -0.04 − -0.01) between instruments (most likely trivial 0/100/0). Both instruments showed very good stability (α = 1.00, CV = 4.28±1.95%). The smallest worthwhile change and typical error values were 1.3 and 0.29 cm, respectively and therefore, the signal-to-noise ratio of both instruments was large: 4.5. Finally, almost perfect correlation between instruments was observed (r = 0.999, most likely positive 100/0/0). Chronojump can be regarded as a sensitive instrument to detect changes in jump height performance over the possible noise around the measure. The results supported the open-source jump mat to be a useful, valid and reliable, low-cost testing device to monitor variations in vertical jumping performance. Institute of Sport in Warsaw 2020-05-25 2020-09 /pmc/articles/PMC7433325/ /pubmed/32879547 http://dx.doi.org/10.5114/biolsport.2020.95636 Text en Copyright © Biology of Sport 2020 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Pueo, Basilio Penichet-Tomas, Alfonso Jimenez-Olmedo, Jose Manuel Reliability and validity of the Chronojump open-source jump mat system |
title | Reliability and validity of the Chronojump open-source jump mat system |
title_full | Reliability and validity of the Chronojump open-source jump mat system |
title_fullStr | Reliability and validity of the Chronojump open-source jump mat system |
title_full_unstemmed | Reliability and validity of the Chronojump open-source jump mat system |
title_short | Reliability and validity of the Chronojump open-source jump mat system |
title_sort | reliability and validity of the chronojump open-source jump mat system |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433325/ https://www.ncbi.nlm.nih.gov/pubmed/32879547 http://dx.doi.org/10.5114/biolsport.2020.95636 |
work_keys_str_mv | AT pueobasilio reliabilityandvalidityofthechronojumpopensourcejumpmatsystem AT penichettomasalfonso reliabilityandvalidityofthechronojumpopensourcejumpmatsystem AT jimenezolmedojosemanuel reliabilityandvalidityofthechronojumpopensourcejumpmatsystem |