Cargando…

Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete

Self-compacting concrete (SCC) should generally be placed continuously, but it is not uncommon for contractors to be forced to use interruptions in concrete works due to delivery delays. The multilayer casting of SCC can cause weak bond conditions in the contact area of subsequent layers. Methods of...

Descripción completa

Detalles Bibliográficos
Autores principales: Dybeł, Piotr, Kucharska, Milena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7435472/
https://www.ncbi.nlm.nih.gov/pubmed/32726978
http://dx.doi.org/10.3390/ma13153330
_version_ 1783572348254814208
author Dybeł, Piotr
Kucharska, Milena
author_facet Dybeł, Piotr
Kucharska, Milena
author_sort Dybeł, Piotr
collection PubMed
description Self-compacting concrete (SCC) should generally be placed continuously, but it is not uncommon for contractors to be forced to use interruptions in concrete works due to delivery delays. The multilayer casting of SCC can cause weak bond conditions in the contact area of subsequent layers. Methods of preventing cold joint or lift line formation for normal concretes are not suitable for self-compacting concretes. This article provides research on the effect of multilayer casting technology on the bond strength between two layers of SCC. Three technological variants of connecting successive layers of SCC mixture on beam elements were analyzed: The free flow of the mixture, dropping the mixture from a greater height, and mechanical disturbance of the first layer. Three delay times were applied: 30, 45, and 60 min between two layers of SCC. In general, the research revealed that, regardless of the multilayer casting variant, the bond strength between two layers decreased as the delay time was extended. The best performance and the lowest drop in bond strength were obtained for samples with a mechanically disturbed first layer, independent of the delay time. This method gave similar results to a reference element made without a break in concreting. It was also demonstrated that current recommendations and standard guidelines for multilayer casting appear to be insufficient for ensuring an adequate bond between layers.
format Online
Article
Text
id pubmed-7435472
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74354722020-08-28 Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete Dybeł, Piotr Kucharska, Milena Materials (Basel) Article Self-compacting concrete (SCC) should generally be placed continuously, but it is not uncommon for contractors to be forced to use interruptions in concrete works due to delivery delays. The multilayer casting of SCC can cause weak bond conditions in the contact area of subsequent layers. Methods of preventing cold joint or lift line formation for normal concretes are not suitable for self-compacting concretes. This article provides research on the effect of multilayer casting technology on the bond strength between two layers of SCC. Three technological variants of connecting successive layers of SCC mixture on beam elements were analyzed: The free flow of the mixture, dropping the mixture from a greater height, and mechanical disturbance of the first layer. Three delay times were applied: 30, 45, and 60 min between two layers of SCC. In general, the research revealed that, regardless of the multilayer casting variant, the bond strength between two layers decreased as the delay time was extended. The best performance and the lowest drop in bond strength were obtained for samples with a mechanically disturbed first layer, independent of the delay time. This method gave similar results to a reference element made without a break in concreting. It was also demonstrated that current recommendations and standard guidelines for multilayer casting appear to be insufficient for ensuring an adequate bond between layers. MDPI 2020-07-27 /pmc/articles/PMC7435472/ /pubmed/32726978 http://dx.doi.org/10.3390/ma13153330 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dybeł, Piotr
Kucharska, Milena
Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title_full Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title_fullStr Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title_full_unstemmed Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title_short Effect of Placement Technology on the Bond Strength Between Two Layers of Self-Compacting Concrete
title_sort effect of placement technology on the bond strength between two layers of self-compacting concrete
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7435472/
https://www.ncbi.nlm.nih.gov/pubmed/32726978
http://dx.doi.org/10.3390/ma13153330
work_keys_str_mv AT dybełpiotr effectofplacementtechnologyonthebondstrengthbetweentwolayersofselfcompactingconcrete
AT kucharskamilena effectofplacementtechnologyonthebondstrengthbetweentwolayersofselfcompactingconcrete