Cargando…

Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material

In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that re...

Descripción completa

Detalles Bibliográficos
Autores principales: Bencun, Mladen, Ender, Andreas, Wiedemeier, Daniel B., Mehl, Albert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7435702/
https://www.ncbi.nlm.nih.gov/pubmed/32748827
http://dx.doi.org/10.3390/ma13153407
_version_ 1783572383661031424
author Bencun, Mladen
Ender, Andreas
Wiedemeier, Daniel B.
Mehl, Albert
author_facet Bencun, Mladen
Ender, Andreas
Wiedemeier, Daniel B.
Mehl, Albert
author_sort Bencun, Mladen
collection PubMed
description In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated with a Computer-aided design and computer-aided manufacturing (CAD/CAM) system and divided into four groups: (A) reinforced composite (RC); (B) human dentin (HD); (C) polymethyl methacrylate (PM); and (D) hybrid ceramic (HC). Sixty-four feldspar ceramic crowns were designed with the biocopy mode, fabricated with a CAD/CAM system, luted on the dies, and then with the roots embedded in polymethyl methacrylate. Care was taken to position all specimens of the same morphology identically. Thermo-mechanical load cycling was performed in a chewing simulator followed by fractural loading of the crowns. A mixed effect linear model was fitted to the data, and pairwise contrasts were estimated on the marginal means and corrected for multiple testing according to Tukey (α = 0.05). The means for fracture load (N) were 2435 N (95% CI (2162, 2709)) for hybrid ceramic, 1838 N (95% CI (1565, 2112)) for reinforced composite, 1670 N (95% CI (1396, 1943)) for human tooth and 1142 N (95% CI (868, 1415)) for polymethyl methacrylate abutment materials. Post-hoc pairwise contrasts revealed a statistically significant (p < 0.05) difference among all groups except for reinforced composite and human dentin (p = 0.76). The results indicate that the mechanical properties of abutment dies play a significant role for a possible substitution of natural teeth in in vitro studies.
format Online
Article
Text
id pubmed-7435702
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74357022020-08-28 Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material Bencun, Mladen Ender, Andreas Wiedemeier, Daniel B. Mehl, Albert Materials (Basel) Article In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated with a Computer-aided design and computer-aided manufacturing (CAD/CAM) system and divided into four groups: (A) reinforced composite (RC); (B) human dentin (HD); (C) polymethyl methacrylate (PM); and (D) hybrid ceramic (HC). Sixty-four feldspar ceramic crowns were designed with the biocopy mode, fabricated with a CAD/CAM system, luted on the dies, and then with the roots embedded in polymethyl methacrylate. Care was taken to position all specimens of the same morphology identically. Thermo-mechanical load cycling was performed in a chewing simulator followed by fractural loading of the crowns. A mixed effect linear model was fitted to the data, and pairwise contrasts were estimated on the marginal means and corrected for multiple testing according to Tukey (α = 0.05). The means for fracture load (N) were 2435 N (95% CI (2162, 2709)) for hybrid ceramic, 1838 N (95% CI (1565, 2112)) for reinforced composite, 1670 N (95% CI (1396, 1943)) for human tooth and 1142 N (95% CI (868, 1415)) for polymethyl methacrylate abutment materials. Post-hoc pairwise contrasts revealed a statistically significant (p < 0.05) difference among all groups except for reinforced composite and human dentin (p = 0.76). The results indicate that the mechanical properties of abutment dies play a significant role for a possible substitution of natural teeth in in vitro studies. MDPI 2020-08-02 /pmc/articles/PMC7435702/ /pubmed/32748827 http://dx.doi.org/10.3390/ma13153407 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bencun, Mladen
Ender, Andreas
Wiedemeier, Daniel B.
Mehl, Albert
Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title_full Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title_fullStr Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title_full_unstemmed Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title_short Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material
title_sort fracture load of cad/cam feldspathic crowns influenced by abutment material
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7435702/
https://www.ncbi.nlm.nih.gov/pubmed/32748827
http://dx.doi.org/10.3390/ma13153407
work_keys_str_mv AT bencunmladen fractureloadofcadcamfeldspathiccrownsinfluencedbyabutmentmaterial
AT enderandreas fractureloadofcadcamfeldspathiccrownsinfluencedbyabutmentmaterial
AT wiedemeierdanielb fractureloadofcadcamfeldspathiccrownsinfluencedbyabutmentmaterial
AT mehlalbert fractureloadofcadcamfeldspathiccrownsinfluencedbyabutmentmaterial