Cargando…

Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry

Polarized low-coherence interferometry (PLCI) is widely used for the demodulation of Fabry–Perot (F-P) sensors. To avoid the influence of noise and dispersion on interference fringes, this paper proposes a data processing method in which the wavelet tools are applied to extract useful information fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Cui, Jiwen, Niu, Yizhao, Dang, Hong, Feng, Kunpeng, Sun, Xun, Tan, Jiubin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7436100/
https://www.ncbi.nlm.nih.gov/pubmed/32751651
http://dx.doi.org/10.3390/s20154249
_version_ 1783572476153823232
author Cui, Jiwen
Niu, Yizhao
Dang, Hong
Feng, Kunpeng
Sun, Xun
Tan, Jiubin
author_facet Cui, Jiwen
Niu, Yizhao
Dang, Hong
Feng, Kunpeng
Sun, Xun
Tan, Jiubin
author_sort Cui, Jiwen
collection PubMed
description Polarized low-coherence interferometry (PLCI) is widely used for the demodulation of Fabry–Perot (F-P) sensors. To avoid the influence of noise and dispersion on interference fringes, this paper proposes a data processing method in which the wavelet tools are applied to extract useful information from the extremum locations and envelope center of the fringes. Firstly, the wavelet threshold denoising (WTD) algorithm is used to remove electrical noise, and the complex Morlet wavelet is used to extract the fringe envelope. Based on this, the envelope center is used to predict the extremum locations of the specified order in its adjacent interval, the predicted locations are used as references to track the exact extremum locations, and the middle location of the peak and valley values is obtained to demodulate the F-P cavity accurately. The validity of this demodulation theory is verified by an air F-P cavity whose cavity length varies from 17 to 20 μm. With a sampling interval of 30 nm, the experimental results indicate that the repeatability accuracy is higher than 6.04 nm, and the resolution is better than 4.0 nm.
format Online
Article
Text
id pubmed-7436100
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74361002020-08-24 Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry Cui, Jiwen Niu, Yizhao Dang, Hong Feng, Kunpeng Sun, Xun Tan, Jiubin Sensors (Basel) Article Polarized low-coherence interferometry (PLCI) is widely used for the demodulation of Fabry–Perot (F-P) sensors. To avoid the influence of noise and dispersion on interference fringes, this paper proposes a data processing method in which the wavelet tools are applied to extract useful information from the extremum locations and envelope center of the fringes. Firstly, the wavelet threshold denoising (WTD) algorithm is used to remove electrical noise, and the complex Morlet wavelet is used to extract the fringe envelope. Based on this, the envelope center is used to predict the extremum locations of the specified order in its adjacent interval, the predicted locations are used as references to track the exact extremum locations, and the middle location of the peak and valley values is obtained to demodulate the F-P cavity accurately. The validity of this demodulation theory is verified by an air F-P cavity whose cavity length varies from 17 to 20 μm. With a sampling interval of 30 nm, the experimental results indicate that the repeatability accuracy is higher than 6.04 nm, and the resolution is better than 4.0 nm. MDPI 2020-07-30 /pmc/articles/PMC7436100/ /pubmed/32751651 http://dx.doi.org/10.3390/s20154249 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cui, Jiwen
Niu, Yizhao
Dang, Hong
Feng, Kunpeng
Sun, Xun
Tan, Jiubin
Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title_full Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title_fullStr Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title_full_unstemmed Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title_short Demodulation Method of F-P Sensor Based on Wavelet Transform and Polarization Low Coherence Interferometry
title_sort demodulation method of f-p sensor based on wavelet transform and polarization low coherence interferometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7436100/
https://www.ncbi.nlm.nih.gov/pubmed/32751651
http://dx.doi.org/10.3390/s20154249
work_keys_str_mv AT cuijiwen demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry
AT niuyizhao demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry
AT danghong demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry
AT fengkunpeng demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry
AT sunxun demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry
AT tanjiubin demodulationmethodoffpsensorbasedonwavelettransformandpolarizationlowcoherenceinterferometry