Cargando…
A New Approach for Testing Fetal Heart Rate Monitors
In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In th...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7436177/ https://www.ncbi.nlm.nih.gov/pubmed/32722397 http://dx.doi.org/10.3390/s20154139 |
_version_ | 1783572493283360768 |
---|---|
author | Bibbo, Daniele Klinkovsky, Tomas Penhaker, Marek Kudrna, Petr Peter, Lukas Augustynek, Martin Kašík, Vladimír Kubicek, Jan Selamat, Ali Cerny, Martin Bielcik, Daniel |
author_facet | Bibbo, Daniele Klinkovsky, Tomas Penhaker, Marek Kudrna, Petr Peter, Lukas Augustynek, Martin Kašík, Vladimír Kubicek, Jan Selamat, Ali Cerny, Martin Bielcik, Daniel |
author_sort | Bibbo, Daniele |
collection | PubMed |
description | In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother’s heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within ±3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses. |
format | Online Article Text |
id | pubmed-7436177 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74361772020-08-24 A New Approach for Testing Fetal Heart Rate Monitors Bibbo, Daniele Klinkovsky, Tomas Penhaker, Marek Kudrna, Petr Peter, Lukas Augustynek, Martin Kašík, Vladimír Kubicek, Jan Selamat, Ali Cerny, Martin Bielcik, Daniel Sensors (Basel) Article In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother’s heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within ±3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses. MDPI 2020-07-25 /pmc/articles/PMC7436177/ /pubmed/32722397 http://dx.doi.org/10.3390/s20154139 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bibbo, Daniele Klinkovsky, Tomas Penhaker, Marek Kudrna, Petr Peter, Lukas Augustynek, Martin Kašík, Vladimír Kubicek, Jan Selamat, Ali Cerny, Martin Bielcik, Daniel A New Approach for Testing Fetal Heart Rate Monitors |
title | A New Approach for Testing Fetal Heart Rate Monitors |
title_full | A New Approach for Testing Fetal Heart Rate Monitors |
title_fullStr | A New Approach for Testing Fetal Heart Rate Monitors |
title_full_unstemmed | A New Approach for Testing Fetal Heart Rate Monitors |
title_short | A New Approach for Testing Fetal Heart Rate Monitors |
title_sort | new approach for testing fetal heart rate monitors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7436177/ https://www.ncbi.nlm.nih.gov/pubmed/32722397 http://dx.doi.org/10.3390/s20154139 |
work_keys_str_mv | AT bibbodaniele anewapproachfortestingfetalheartratemonitors AT klinkovskytomas anewapproachfortestingfetalheartratemonitors AT penhakermarek anewapproachfortestingfetalheartratemonitors AT kudrnapetr anewapproachfortestingfetalheartratemonitors AT peterlukas anewapproachfortestingfetalheartratemonitors AT augustynekmartin anewapproachfortestingfetalheartratemonitors AT kasikvladimir anewapproachfortestingfetalheartratemonitors AT kubicekjan anewapproachfortestingfetalheartratemonitors AT selamatali anewapproachfortestingfetalheartratemonitors AT cernymartin anewapproachfortestingfetalheartratemonitors AT bielcikdaniel anewapproachfortestingfetalheartratemonitors AT bibbodaniele newapproachfortestingfetalheartratemonitors AT klinkovskytomas newapproachfortestingfetalheartratemonitors AT penhakermarek newapproachfortestingfetalheartratemonitors AT kudrnapetr newapproachfortestingfetalheartratemonitors AT peterlukas newapproachfortestingfetalheartratemonitors AT augustynekmartin newapproachfortestingfetalheartratemonitors AT kasikvladimir newapproachfortestingfetalheartratemonitors AT kubicekjan newapproachfortestingfetalheartratemonitors AT selamatali newapproachfortestingfetalheartratemonitors AT cernymartin newapproachfortestingfetalheartratemonitors AT bielcikdaniel newapproachfortestingfetalheartratemonitors |