Cargando…
Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI
AIMS: The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. METHODS: A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospe...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Editorial Society of Bone and Joint Surgery
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7437524/ https://www.ncbi.nlm.nih.gov/pubmed/32864114 http://dx.doi.org/10.1302/2046-3758.97.BJR-2019-0325.R2 |
_version_ | 1783572642589048832 |
---|---|
author | Huang, Zida Li, Wenbo Lee, Gwo-Chin Fang, Xinyu Xing, Li Yang, Bin Lin, Jianhua Zhang, Wenming |
author_facet | Huang, Zida Li, Wenbo Lee, Gwo-Chin Fang, Xinyu Xing, Li Yang, Bin Lin, Jianhua Zhang, Wenming |
author_sort | Huang, Zida |
collection | PubMed |
description | AIMS: The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. METHODS: A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture. RESULTS: A total of 49 PJI and 21 noninfection patients were finally included. Of the 39 culture-positive PJI cases, mNGS results were positive in 37 patients (94.9%), and were consistent with culture results at the genus level in 32 patients (86.5%) and at the species level in 27 patients (73.0%). Metagenomic next-generation sequencing additionally identified 15 pathogens from five culture-positive and all ten culture-negative PJI cases, and even one pathogen from one noninfection patient, while yielding no positive findings in any primary arthroplasty. However, seven pathogens identified by culture were missed by mNGS. The sensitivity of mNGS for diagnosing PJI was 95.9%, which was significantly higher than that of comprehensive culture (79.6%; p = 0.014). The specificity is similar between mNGS and comprehensive culture (95.2% and 95.2%, respectively; p = 1.0). CONCLUSION: Metagenomic next-generation sequencing can effectively identify pathogens from synovial fluid of PJI patients, and demonstrates high accuracy in diagnosing PJI. Cite this article: Bone Joint Res 2020;9(7):440–449. |
format | Online Article Text |
id | pubmed-7437524 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The British Editorial Society of Bone and Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-74375242020-08-28 Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI Huang, Zida Li, Wenbo Lee, Gwo-Chin Fang, Xinyu Xing, Li Yang, Bin Lin, Jianhua Zhang, Wenming Bone Joint Res Infection AIMS: The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. METHODS: A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture. RESULTS: A total of 49 PJI and 21 noninfection patients were finally included. Of the 39 culture-positive PJI cases, mNGS results were positive in 37 patients (94.9%), and were consistent with culture results at the genus level in 32 patients (86.5%) and at the species level in 27 patients (73.0%). Metagenomic next-generation sequencing additionally identified 15 pathogens from five culture-positive and all ten culture-negative PJI cases, and even one pathogen from one noninfection patient, while yielding no positive findings in any primary arthroplasty. However, seven pathogens identified by culture were missed by mNGS. The sensitivity of mNGS for diagnosing PJI was 95.9%, which was significantly higher than that of comprehensive culture (79.6%; p = 0.014). The specificity is similar between mNGS and comprehensive culture (95.2% and 95.2%, respectively; p = 1.0). CONCLUSION: Metagenomic next-generation sequencing can effectively identify pathogens from synovial fluid of PJI patients, and demonstrates high accuracy in diagnosing PJI. Cite this article: Bone Joint Res 2020;9(7):440–449. The British Editorial Society of Bone and Joint Surgery 2020-08-19 /pmc/articles/PMC7437524/ /pubmed/32864114 http://dx.doi.org/10.1302/2046-3758.97.BJR-2019-0325.R2 Text en © 2020 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. |
spellingShingle | Infection Huang, Zida Li, Wenbo Lee, Gwo-Chin Fang, Xinyu Xing, Li Yang, Bin Lin, Jianhua Zhang, Wenming Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title | Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title_full | Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title_fullStr | Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title_full_unstemmed | Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title_short | Metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mNGS for diagnosing PJI |
title_sort | metagenomic next-generation sequencing of synovial fluid demonstrates high accuracy in prosthetic joint infection diagnostics: mngs for diagnosing pji |
topic | Infection |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7437524/ https://www.ncbi.nlm.nih.gov/pubmed/32864114 http://dx.doi.org/10.1302/2046-3758.97.BJR-2019-0325.R2 |
work_keys_str_mv | AT huangzida metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT liwenbo metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT leegwochin metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT fangxinyu metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT xingli metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT yangbin metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT linjianhua metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji AT zhangwenming metagenomicnextgenerationsequencingofsynovialfluiddemonstrateshighaccuracyinprostheticjointinfectiondiagnosticsmngsfordiagnosingpji |