Cargando…

Ion chromatography as candidate reference method for the determination of chloride in human serum

BACKGROUND: We developed an ion chromatography (IC) method for measurement of chloride in human serum which was regarded as a simple, rapid, accurate, and sensitive technique. The method will be hopefully selected as a candidate reference method. METHOD: Serum aliquots of 0.1 mL were diluted 500 tim...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Min, Tu, Minmin, Zhang, Wei, Zou, Jihua, Zhang, Man, Cao, Zheng, Zou, Bingde
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7439436/
https://www.ncbi.nlm.nih.gov/pubmed/32705715
http://dx.doi.org/10.1002/jcla.23296
_version_ 1783572981767733248
author Shen, Min
Tu, Minmin
Zhang, Wei
Zou, Jihua
Zhang, Man
Cao, Zheng
Zou, Bingde
author_facet Shen, Min
Tu, Minmin
Zhang, Wei
Zou, Jihua
Zhang, Man
Cao, Zheng
Zou, Bingde
author_sort Shen, Min
collection PubMed
description BACKGROUND: We developed an ion chromatography (IC) method for measurement of chloride in human serum which was regarded as a simple, rapid, accurate, and sensitive technique. The method will be hopefully selected as a candidate reference method. METHOD: Serum aliquots of 0.1 mL were diluted 500 times with Milli‐Q water, and chloride in serum samples was measured by IC with a gradient elution procedure using a KOH eluent generator. RESULTS: Based on the data, chloride in human serum was well detected by IC. The calibration curve for chloride was linear in the concentration range from 0 to 0.42 mmol/L with a correlation coefficient of .99995 under the optimum experimental conditions. The chloride concentration had a good linear relationship with the peak areas of chloride. This method was sensitive because of the low limit of detection (LOD) and the low limit of quantification (LOQ) 9.87 × 10(−5) mmol/L and 3.27 × 10(−4) mmol/L, respectively. Besides, the method was highly precise with the within‐run coefficient of variations (CVs) for the measurement of low, medium, and high concentration level samples 0.32%, 0.73%, and 0.50%. As for the evaluation of accuracy, the biases were less than ±1% and 2% by comparing with National Institute of Science and Technology (NIST) standard material SRM 956d and 2013‐2018 IFCC‐RELA samples, respectively. Finally, the biases between IC method and the inductively coupled plasma mass spectrometry (ICP‐MS) method were less than 1% which showed good agreement. CONCLUSION: Ion chromatography is a simple sample treatment procedure for the determination of chloride in human serum with high sensitivity and specificity. The proposed method could be recommended as a candidate reference method for the determination of serum chloride in human serum.
format Online
Article
Text
id pubmed-7439436
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-74394362020-08-21 Ion chromatography as candidate reference method for the determination of chloride in human serum Shen, Min Tu, Minmin Zhang, Wei Zou, Jihua Zhang, Man Cao, Zheng Zou, Bingde J Clin Lab Anal Research Articles BACKGROUND: We developed an ion chromatography (IC) method for measurement of chloride in human serum which was regarded as a simple, rapid, accurate, and sensitive technique. The method will be hopefully selected as a candidate reference method. METHOD: Serum aliquots of 0.1 mL were diluted 500 times with Milli‐Q water, and chloride in serum samples was measured by IC with a gradient elution procedure using a KOH eluent generator. RESULTS: Based on the data, chloride in human serum was well detected by IC. The calibration curve for chloride was linear in the concentration range from 0 to 0.42 mmol/L with a correlation coefficient of .99995 under the optimum experimental conditions. The chloride concentration had a good linear relationship with the peak areas of chloride. This method was sensitive because of the low limit of detection (LOD) and the low limit of quantification (LOQ) 9.87 × 10(−5) mmol/L and 3.27 × 10(−4) mmol/L, respectively. Besides, the method was highly precise with the within‐run coefficient of variations (CVs) for the measurement of low, medium, and high concentration level samples 0.32%, 0.73%, and 0.50%. As for the evaluation of accuracy, the biases were less than ±1% and 2% by comparing with National Institute of Science and Technology (NIST) standard material SRM 956d and 2013‐2018 IFCC‐RELA samples, respectively. Finally, the biases between IC method and the inductively coupled plasma mass spectrometry (ICP‐MS) method were less than 1% which showed good agreement. CONCLUSION: Ion chromatography is a simple sample treatment procedure for the determination of chloride in human serum with high sensitivity and specificity. The proposed method could be recommended as a candidate reference method for the determination of serum chloride in human serum. John Wiley and Sons Inc. 2020-07-24 /pmc/articles/PMC7439436/ /pubmed/32705715 http://dx.doi.org/10.1002/jcla.23296 Text en © 2020 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Shen, Min
Tu, Minmin
Zhang, Wei
Zou, Jihua
Zhang, Man
Cao, Zheng
Zou, Bingde
Ion chromatography as candidate reference method for the determination of chloride in human serum
title Ion chromatography as candidate reference method for the determination of chloride in human serum
title_full Ion chromatography as candidate reference method for the determination of chloride in human serum
title_fullStr Ion chromatography as candidate reference method for the determination of chloride in human serum
title_full_unstemmed Ion chromatography as candidate reference method for the determination of chloride in human serum
title_short Ion chromatography as candidate reference method for the determination of chloride in human serum
title_sort ion chromatography as candidate reference method for the determination of chloride in human serum
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7439436/
https://www.ncbi.nlm.nih.gov/pubmed/32705715
http://dx.doi.org/10.1002/jcla.23296
work_keys_str_mv AT shenmin ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT tuminmin ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT zhangwei ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT zoujihua ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT zhangman ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT caozheng ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum
AT zoubingde ionchromatographyascandidatereferencemethodforthedeterminationofchlorideinhumanserum