Cargando…
Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline
INTRODUCTION: During the first month of the SARS-CoV-2 outbreak, rapid development of PCR-based diagnostic tests became a global priority so that timely diagnosis, isolation, and contact tracing could minimize the advancing pandemic surge. Designing these tests for broad, long-term detection was com...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier B.V.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441044/ https://www.ncbi.nlm.nih.gov/pubmed/32889496 http://dx.doi.org/10.1016/j.jcv.2020.104581 |
_version_ | 1783573231586770944 |
---|---|
author | Kuchinski, Kevin S. Jassem, Agatha N. Prystajecky, Natalie A. |
author_facet | Kuchinski, Kevin S. Jassem, Agatha N. Prystajecky, Natalie A. |
author_sort | Kuchinski, Kevin S. |
collection | PubMed |
description | INTRODUCTION: During the first month of the SARS-CoV-2 outbreak, rapid development of PCR-based diagnostic tests became a global priority so that timely diagnosis, isolation, and contact tracing could minimize the advancing pandemic surge. Designing these tests for broad, long-term detection was complicated by limited information about the novel virus’ genome sequence and how it might mutate during global spread and adaptation to humans. METHODS: We assessed eight widely adopted lab developed PCR tests for SARS-CoV-2 against 15,001 SARS-CoV-2 genome sequences. Using a custom bioinformatic pipeline called PCR_strainer, we identified all mismatches and sequence variants in genome locations targeted by 15 sets of primer/probe oligonucleotides from these assays. RESULTS: For 12 out of 15 primer/probe sets, over 98 % of SARS-CoV-2 genomes had no mismatches. Two primer/probe sets contained a single mismatch in the reverse primer that was present in over 99 % of genomes. One primer/probe set targeted a location with extensive polymorphisms with 23 sequence observed variants at the forward primer location. One of these variants, which contains three nucleotide mismatches, arose in February as part of the emergence of a viral clade and was present in 18.8 % of the genomes we analyzed. DISCUSSION: Most early PCR diagnostic tests for SARS-CoV-2 remain inclusive of circulating viral diversity, but three assays with extensive mismatches highlight assay design challenges for novel pathogens and provide valuable lessons for PCR assay design during future outbreaks. Our bioinformatics pipeline is also presented as a useful general-purpose tool for assessing PCR diagnostics assays against circulating strains. |
format | Online Article Text |
id | pubmed-7441044 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Published by Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74410442020-08-21 Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline Kuchinski, Kevin S. Jassem, Agatha N. Prystajecky, Natalie A. J Clin Virol Article INTRODUCTION: During the first month of the SARS-CoV-2 outbreak, rapid development of PCR-based diagnostic tests became a global priority so that timely diagnosis, isolation, and contact tracing could minimize the advancing pandemic surge. Designing these tests for broad, long-term detection was complicated by limited information about the novel virus’ genome sequence and how it might mutate during global spread and adaptation to humans. METHODS: We assessed eight widely adopted lab developed PCR tests for SARS-CoV-2 against 15,001 SARS-CoV-2 genome sequences. Using a custom bioinformatic pipeline called PCR_strainer, we identified all mismatches and sequence variants in genome locations targeted by 15 sets of primer/probe oligonucleotides from these assays. RESULTS: For 12 out of 15 primer/probe sets, over 98 % of SARS-CoV-2 genomes had no mismatches. Two primer/probe sets contained a single mismatch in the reverse primer that was present in over 99 % of genomes. One primer/probe set targeted a location with extensive polymorphisms with 23 sequence observed variants at the forward primer location. One of these variants, which contains three nucleotide mismatches, arose in February as part of the emergence of a viral clade and was present in 18.8 % of the genomes we analyzed. DISCUSSION: Most early PCR diagnostic tests for SARS-CoV-2 remain inclusive of circulating viral diversity, but three assays with extensive mismatches highlight assay design challenges for novel pathogens and provide valuable lessons for PCR assay design during future outbreaks. Our bioinformatics pipeline is also presented as a useful general-purpose tool for assessing PCR diagnostics assays against circulating strains. Published by Elsevier B.V. 2020-10 2020-08-21 /pmc/articles/PMC7441044/ /pubmed/32889496 http://dx.doi.org/10.1016/j.jcv.2020.104581 Text en Crown Copyright © 2020 Published by Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Kuchinski, Kevin S. Jassem, Agatha N. Prystajecky, Natalie A. Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title | Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title_full | Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title_fullStr | Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title_full_unstemmed | Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title_short | Assessing oligonucleotide designs from early lab developed PCR diagnostic tests for SARS-CoV-2 using the PCR_strainer pipeline |
title_sort | assessing oligonucleotide designs from early lab developed pcr diagnostic tests for sars-cov-2 using the pcr_strainer pipeline |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441044/ https://www.ncbi.nlm.nih.gov/pubmed/32889496 http://dx.doi.org/10.1016/j.jcv.2020.104581 |
work_keys_str_mv | AT kuchinskikevins assessingoligonucleotidedesignsfromearlylabdevelopedpcrdiagnostictestsforsarscov2usingthepcrstrainerpipeline AT jassemagathan assessingoligonucleotidedesignsfromearlylabdevelopedpcrdiagnostictestsforsarscov2usingthepcrstrainerpipeline AT prystajeckynataliea assessingoligonucleotidedesignsfromearlylabdevelopedpcrdiagnostictestsforsarscov2usingthepcrstrainerpipeline |