Environmental contamination in the isolation rooms of COVID-19 patients with severe pneumonia requiring mechanical ventilation or high-flow oxygen therapy

BACKGROUND: Identifying the extent of environmental contamination of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for infection control and prevention. The extent of environmental contamination has not been fully investigated in the context of severe coronavirus disease...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, J.Y., An, S., Sohn, Y., Cho, Y., Hyun, J.H., Baek, Y.J., Kim, M.H., Jeong, S.J., Kim, J.H., Ku, N.S., Yeom, J.-S., Smith, D.M., Lee, H., Yong, D., Lee, Y.-J., Kim, J.W., Kim, H.R., Hwang, J., Choi, J.Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Healthcare Infection Society. Published by Elsevier Ltd. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441047/
https://www.ncbi.nlm.nih.gov/pubmed/32828864
http://dx.doi.org/10.1016/j.jhin.2020.08.014
Descripción
Sumario:BACKGROUND: Identifying the extent of environmental contamination of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for infection control and prevention. The extent of environmental contamination has not been fully investigated in the context of severe coronavirus disease (COVID-19) patients. AIM: To investigate environmental SARS-CoV-2 contamination in the isolation rooms of severe COVID-19 patients requiring mechanical ventilation or high-flow oxygen therapy. METHODS: Environmental swab samples and air samples were collected from the isolation rooms of three COVID-19 patients with severe pneumonia. Patients 1 and 2 received mechanical ventilation with a closed suction system, while patient 3 received high-flow oxygen therapy and non-invasive ventilation. Real-time reverse transcription–polymerase chain reaction (rRT–PCR) was used to detect SARS-CoV-2; viral cultures were performed for samples not negative on rRT–PCR. FINDINGS: Of the 48 swab samples collected in the rooms of patients 1 and 2, only samples from the outside surfaces of the endotracheal tubes tested positive for SARS-CoV-2 by rRT–PCR. However, in patient 3's room, 13 of the 28 environmental samples (fomites, fixed structures, and ventilation exit on the ceiling) showed positive results. Air samples were negative for SARS-CoV-2. Viable viruses were identified on the surface of the endotracheal tube of patient 1 and seven sites in patient 3's room. CONCLUSION: Environmental contamination of SARS-CoV-2 may be a route of viral transmission. However, it might be minimized when patients receive mechanical ventilation with a closed suction system. These findings can provide evidence for guidelines for the safe use of personal protective equipment.