Cargando…
Environmental contamination in the isolation rooms of COVID-19 patients with severe pneumonia requiring mechanical ventilation or high-flow oxygen therapy
BACKGROUND: Identifying the extent of environmental contamination of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for infection control and prevention. The extent of environmental contamination has not been fully investigated in the context of severe coronavirus disease...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Healthcare Infection Society. Published by Elsevier Ltd.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441047/ https://www.ncbi.nlm.nih.gov/pubmed/32828864 http://dx.doi.org/10.1016/j.jhin.2020.08.014 |
Sumario: | BACKGROUND: Identifying the extent of environmental contamination of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for infection control and prevention. The extent of environmental contamination has not been fully investigated in the context of severe coronavirus disease (COVID-19) patients. AIM: To investigate environmental SARS-CoV-2 contamination in the isolation rooms of severe COVID-19 patients requiring mechanical ventilation or high-flow oxygen therapy. METHODS: Environmental swab samples and air samples were collected from the isolation rooms of three COVID-19 patients with severe pneumonia. Patients 1 and 2 received mechanical ventilation with a closed suction system, while patient 3 received high-flow oxygen therapy and non-invasive ventilation. Real-time reverse transcription–polymerase chain reaction (rRT–PCR) was used to detect SARS-CoV-2; viral cultures were performed for samples not negative on rRT–PCR. FINDINGS: Of the 48 swab samples collected in the rooms of patients 1 and 2, only samples from the outside surfaces of the endotracheal tubes tested positive for SARS-CoV-2 by rRT–PCR. However, in patient 3's room, 13 of the 28 environmental samples (fomites, fixed structures, and ventilation exit on the ceiling) showed positive results. Air samples were negative for SARS-CoV-2. Viable viruses were identified on the surface of the endotracheal tube of patient 1 and seven sites in patient 3's room. CONCLUSION: Environmental contamination of SARS-CoV-2 may be a route of viral transmission. However, it might be minimized when patients receive mechanical ventilation with a closed suction system. These findings can provide evidence for guidelines for the safe use of personal protective equipment. |
---|