Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy

BACKGROUND: Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision. The variable clinical manifestations may result in differential diagnostic difficulties. The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segme...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Zi-Yan, Huang, Ting, Lu, Lu, Qu, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441261/
https://www.ncbi.nlm.nih.gov/pubmed/32874979
http://dx.doi.org/10.12998/wjcc.v8.i15.3249
_version_ 1783573263495987200
author Yu, Zi-Yan
Huang, Ting
Lu, Lu
Qu, Bo
author_facet Yu, Zi-Yan
Huang, Ting
Lu, Lu
Qu, Bo
author_sort Yu, Zi-Yan
collection PubMed
description BACKGROUND: Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision. The variable clinical manifestations may result in differential diagnostic difficulties. The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement. Therefore, we analyzed the agreement, difference, and correlation of chamber angle parameters such as angel opening distance at 500 μm (AOD500) and trabeculo-iris space area at 500 μm(2) (TISA500) measured by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). AIM: To compare the differences, correlation, and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM. METHODS: Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects (72 eyes). All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University. Data of the two groups (AOD500 and TISA500) were compared by nonparametric tests. Pearson correlative analysis and Bland–Altman analysis were used to compare the correlation and agreement. RESULTS: There were no significant differences between AS-OCT and UBM in measuring AOD500 (P1 = 0.110, P2 = 0.633, P3 = 0.078, and P4 = 0.474) and TISA500 (P1 = 0.584, P2 = 0.889, P3 = 0.297, and P4 = 0.550) of the four quadrants of the anterior chamber angle. There was a high correlation in measuring AOD500 (r1 = 0.562, r2 = 0.671, r3 = 0.635, and r4 = 0.720; P < 0.001) and TISA500 (r1 = 0.584, r2 = 0.889, r3 = 0.297, and r4 = 0.550; P < 0.001). There was a good agreement in measuring AOD500 and TISA500 by the two modalities. CONCLUSION: There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM. They are interchangeable under some circumstances. AS-OCT proves to be a better early screening tool for glaucoma.
format Online
Article
Text
id pubmed-7441261
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-74412612020-08-31 Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy Yu, Zi-Yan Huang, Ting Lu, Lu Qu, Bo World J Clin Cases Clinical Trials Study BACKGROUND: Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision. The variable clinical manifestations may result in differential diagnostic difficulties. The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement. Therefore, we analyzed the agreement, difference, and correlation of chamber angle parameters such as angel opening distance at 500 μm (AOD500) and trabeculo-iris space area at 500 μm(2) (TISA500) measured by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). AIM: To compare the differences, correlation, and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM. METHODS: Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects (72 eyes). All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University. Data of the two groups (AOD500 and TISA500) were compared by nonparametric tests. Pearson correlative analysis and Bland–Altman analysis were used to compare the correlation and agreement. RESULTS: There were no significant differences between AS-OCT and UBM in measuring AOD500 (P1 = 0.110, P2 = 0.633, P3 = 0.078, and P4 = 0.474) and TISA500 (P1 = 0.584, P2 = 0.889, P3 = 0.297, and P4 = 0.550) of the four quadrants of the anterior chamber angle. There was a high correlation in measuring AOD500 (r1 = 0.562, r2 = 0.671, r3 = 0.635, and r4 = 0.720; P < 0.001) and TISA500 (r1 = 0.584, r2 = 0.889, r3 = 0.297, and r4 = 0.550; P < 0.001). There was a good agreement in measuring AOD500 and TISA500 by the two modalities. CONCLUSION: There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM. They are interchangeable under some circumstances. AS-OCT proves to be a better early screening tool for glaucoma. Baishideng Publishing Group Inc 2020-08-06 2020-08-06 /pmc/articles/PMC7441261/ /pubmed/32874979 http://dx.doi.org/10.12998/wjcc.v8.i15.3249 Text en ©The Author(s) 2020. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Clinical Trials Study
Yu, Zi-Yan
Huang, Ting
Lu, Lu
Qu, Bo
Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title_full Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title_fullStr Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title_full_unstemmed Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title_short Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
title_sort comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
topic Clinical Trials Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441261/
https://www.ncbi.nlm.nih.gov/pubmed/32874979
http://dx.doi.org/10.12998/wjcc.v8.i15.3249
work_keys_str_mv AT yuziyan comparisonofmeasurementsofanteriorchamberangleviaanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT huangting comparisonofmeasurementsofanteriorchamberangleviaanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT lulu comparisonofmeasurementsofanteriorchamberangleviaanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT qubo comparisonofmeasurementsofanteriorchamberangleviaanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy