Cargando…
Treatment plan quality during online adaptive re-planning
BACKGROUND: Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7441614/ https://www.ncbi.nlm.nih.gov/pubmed/32825848 http://dx.doi.org/10.1186/s13014-020-01641-0 |
Sumario: | BACKGROUND: Online adaptive radiotherapy is intended to prevent plan degradation caused by inter-fractional tumor volume and shape changes, but time limitations make online re-planning challenging. The aim of this study was to compare the quality of online-adapted plans to their respective reference treatment plans. METHODS: Fifty-two patients treated on a ViewRay MRIdian Linac were included in this retrospective study. In total 238 online-adapted plans were analyzed, which were optimized with either changing of the segment weights (n = 85) or full re-optimization (n = 153). Five different treatment sites were evaluated: prostate, abdomen, liver, lung and pelvis. Dosimetric parameters of gross tumor volume (GTV), planning target volume (PTV), 2 cm ring around the PTV and organs at risk (OARs) were considered. The Wilcoxon signed-rank test was used to assess differences between online-adapted and reference treatment plans, p < 0.05 was considered significant. RESULTS: The average duration of the online adaptation, consisting of contour editing, plan optimization and quality assurance (QA), was 24 ± 6 min. The GTV was slightly larger (average ± SD: 1.9% ± 9.0%) in the adapted plans than in the reference plans (p < 0.001). GTV-D(95%) exhibited no significant changes when considering all plans, but GTV-D(2%) increased by 0.40% ± 1.5% on average (p < 0.001). There was a very small yet significant decrease in GTV-coverage for the abdomen plans. The ring D(mean) increased on average by 1.0% ± 3.6% considering all plans (p < 0.001). There was a significant reduction of the dose to the rectum of 4.7% ± 16% on average (p < 0.001) for prostate plans. CONCLUSIONS: Dosimetric quality of online-adapted plans was comparable to reference treatment plans and OAR dose was either comparable or decreased, depending on treatment site. However, dose spillage was slightly increased. |
---|