Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube
The Barricor tube (Becton Dickinson [BD], Sunnyvale, CA, USA) was recently developed to mechanically separate plasma by increasing the centrifugation rate. We compared the Barricor tube with existing serum- and plasma-based tubes based on 35 biochemical analytes and preanalytical turnaround time (TA...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society for Laboratory Medicine
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7443522/ https://www.ncbi.nlm.nih.gov/pubmed/32829587 http://dx.doi.org/10.3343/alm.2021.41.1.114 |
_version_ | 1783573645373734912 |
---|---|
author | Shin, Sunghwan Oh, Jongwon Park, Hyung-Doo |
author_facet | Shin, Sunghwan Oh, Jongwon Park, Hyung-Doo |
author_sort | Shin, Sunghwan |
collection | PubMed |
description | The Barricor tube (Becton Dickinson [BD], Sunnyvale, CA, USA) was recently developed to mechanically separate plasma by increasing the centrifugation rate. We compared the Barricor tube with existing serum- and plasma-based tubes based on 35 biochemical analytes and preanalytical turnaround time (TAT). Blood samples were collected from 30 healthy volunteers in a Barricor tube, serum separating tube (SST, Vacutainer SST II Tube 8.5 mL, #368972; BD), or plasma separating tube (PST, Vacutainer PST Tube 8.0 mL, #367964; BD) in random order. Next, 27 chemistry analytes, six immunochemistry analytes, and two cardiac markers were compared using Passing-Bablok regression and the Bland-Altman method. Preanalytical TAT was measured for each tube. The Barricor tube exhibited bias exceeding the desirable limit for nine and four analytes compared with the SST and PST, respectively. The Barricor tube lactate dehydrogenase value showed a bias of −10.29% and −9.86% compared with that of the SST and PST, respectively. The preanalytical TAT of Barricor tube was 8.8 minutes, which was the shortest among the three tubes. The clinical performance of the Barricor tube was equivalent to that of the SST and PST for most analytes, with an apparent advantage in preanalytical TAT. When using the Barricor tube, the reference range needs to be changed for some analytes that exceed the desirable bias limit. |
format | Online Article Text |
id | pubmed-7443522 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-74435222021-01-01 Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube Shin, Sunghwan Oh, Jongwon Park, Hyung-Doo Ann Lab Med Brief Communication The Barricor tube (Becton Dickinson [BD], Sunnyvale, CA, USA) was recently developed to mechanically separate plasma by increasing the centrifugation rate. We compared the Barricor tube with existing serum- and plasma-based tubes based on 35 biochemical analytes and preanalytical turnaround time (TAT). Blood samples were collected from 30 healthy volunteers in a Barricor tube, serum separating tube (SST, Vacutainer SST II Tube 8.5 mL, #368972; BD), or plasma separating tube (PST, Vacutainer PST Tube 8.0 mL, #367964; BD) in random order. Next, 27 chemistry analytes, six immunochemistry analytes, and two cardiac markers were compared using Passing-Bablok regression and the Bland-Altman method. Preanalytical TAT was measured for each tube. The Barricor tube exhibited bias exceeding the desirable limit for nine and four analytes compared with the SST and PST, respectively. The Barricor tube lactate dehydrogenase value showed a bias of −10.29% and −9.86% compared with that of the SST and PST, respectively. The preanalytical TAT of Barricor tube was 8.8 minutes, which was the shortest among the three tubes. The clinical performance of the Barricor tube was equivalent to that of the SST and PST for most analytes, with an apparent advantage in preanalytical TAT. When using the Barricor tube, the reference range needs to be changed for some analytes that exceed the desirable bias limit. Korean Society for Laboratory Medicine 2021-01 2021-01-01 /pmc/articles/PMC7443522/ /pubmed/32829587 http://dx.doi.org/10.3343/alm.2021.41.1.114 Text en Copyright © Korean Society for Laboratory Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communication Shin, Sunghwan Oh, Jongwon Park, Hyung-Doo Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title | Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title_full | Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title_fullStr | Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title_full_unstemmed | Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title_short | Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube |
title_sort | comparison of three blood collection tubes for 35 biochemical analytes: the becton dickinson barricor tube, serum separating tube, and plasma separating tube |
topic | Brief Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7443522/ https://www.ncbi.nlm.nih.gov/pubmed/32829587 http://dx.doi.org/10.3343/alm.2021.41.1.114 |
work_keys_str_mv | AT shinsunghwan comparisonofthreebloodcollectiontubesfor35biochemicalanalytesthebectondickinsonbarricortubeserumseparatingtubeandplasmaseparatingtube AT ohjongwon comparisonofthreebloodcollectiontubesfor35biochemicalanalytesthebectondickinsonbarricortubeserumseparatingtubeandplasmaseparatingtube AT parkhyungdoo comparisonofthreebloodcollectiontubesfor35biochemicalanalytesthebectondickinsonbarricortubeserumseparatingtubeandplasmaseparatingtube |