Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study

We aimed to evaluate the accuracy and interchangeability of stroke volume and cardiac output measured by electrical velocimetry and transthoracic echocardiography during cesarean delivery. We enrolled 20 parturients in this prospective observational study. We recorded the stroke volume and cardiac o...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, S.M., Liu, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7447428/
https://www.ncbi.nlm.nih.gov/pubmed/32846858
http://dx.doi.org/10.1097/MD.0000000000021914
_version_ 1783574298499219456
author Feng, S.M.
Liu, Jin
author_facet Feng, S.M.
Liu, Jin
author_sort Feng, S.M.
collection PubMed
description We aimed to evaluate the accuracy and interchangeability of stroke volume and cardiac output measured by electrical velocimetry and transthoracic echocardiography during cesarean delivery. We enrolled 20 parturients in this prospective observational study. We recorded the stroke volume and cardiac output using both methods and compared the values at seven specific time points. We analyzed the data using linear regression analysis for Pearson's correlation coefficients and Bland-Altman analysis to determine percentage errors. We conducted a trending ability analysis based on the four-quadrant plot with the concordance rate and correlation coefficient. We recorded 124 paired datasets during cesarean delivery. The correlation coefficients of the measured cardiac output and stroke volume between the two methods were 0.397 (P < .001) and 0.357 (P < .001). The 95% limits of agreement were −1.0 to 8.1 L min(−1) for cardiac output and −10.4 to 90.4 ml for stroke volume. Moreover, the corresponding percentage errors were 62% and 60%. The concordance correlation coefficients were 0.447 (95% CI: 0.313-0.564) for stroke volume and 0.562 (95% CI: 0.442-0.662) for cardiac output. Both methods showed a moderate trending ability for stroke volume (concordance rate: 82% (95% CI: 72–90%)) and cardiac output (concordance rate: 85% (95% CI: 78–93%)). Our findings indicated that electrical velocimetry monitoring has limited accuracy, precision, and interchangeability with transthoracic echocardiography; however, it had a moderate trending ability for stroke volume and cardiac output measurements during cesarean delivery.
format Online
Article
Text
id pubmed-7447428
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-74474282020-09-04 Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study Feng, S.M. Liu, Jin Medicine (Baltimore) 3300 We aimed to evaluate the accuracy and interchangeability of stroke volume and cardiac output measured by electrical velocimetry and transthoracic echocardiography during cesarean delivery. We enrolled 20 parturients in this prospective observational study. We recorded the stroke volume and cardiac output using both methods and compared the values at seven specific time points. We analyzed the data using linear regression analysis for Pearson's correlation coefficients and Bland-Altman analysis to determine percentage errors. We conducted a trending ability analysis based on the four-quadrant plot with the concordance rate and correlation coefficient. We recorded 124 paired datasets during cesarean delivery. The correlation coefficients of the measured cardiac output and stroke volume between the two methods were 0.397 (P < .001) and 0.357 (P < .001). The 95% limits of agreement were −1.0 to 8.1 L min(−1) for cardiac output and −10.4 to 90.4 ml for stroke volume. Moreover, the corresponding percentage errors were 62% and 60%. The concordance correlation coefficients were 0.447 (95% CI: 0.313-0.564) for stroke volume and 0.562 (95% CI: 0.442-0.662) for cardiac output. Both methods showed a moderate trending ability for stroke volume (concordance rate: 82% (95% CI: 72–90%)) and cardiac output (concordance rate: 85% (95% CI: 78–93%)). Our findings indicated that electrical velocimetry monitoring has limited accuracy, precision, and interchangeability with transthoracic echocardiography; however, it had a moderate trending ability for stroke volume and cardiac output measurements during cesarean delivery. Lippincott Williams & Wilkins 2020-08-21 /pmc/articles/PMC7447428/ /pubmed/32846858 http://dx.doi.org/10.1097/MD.0000000000021914 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 3300
Feng, S.M.
Liu, Jin
Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title_full Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title_fullStr Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title_full_unstemmed Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title_short Electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: A prospective observational study
title_sort electrical velocimetry has limited accuracy and precision and moderate trending ability compared with transthoracic echocardiography for cardiac output measurement during cesarean delivery: a prospective observational study
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7447428/
https://www.ncbi.nlm.nih.gov/pubmed/32846858
http://dx.doi.org/10.1097/MD.0000000000021914
work_keys_str_mv AT fengsm electricalvelocimetryhaslimitedaccuracyandprecisionandmoderatetrendingabilitycomparedwithtransthoracicechocardiographyforcardiacoutputmeasurementduringcesareandeliveryaprospectiveobservationalstudy
AT liujin electricalvelocimetryhaslimitedaccuracyandprecisionandmoderatetrendingabilitycomparedwithtransthoracicechocardiographyforcardiacoutputmeasurementduringcesareandeliveryaprospectiveobservationalstudy