Cargando…

Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port

Laparoscopic inguinal herniorrhaphy has been well established for the management of primary and recurrent inguinal hernias. Single-incision laparoscopic surgery (SILS) has now been accepted as a less invasive alternative to conventional laparoscopic surgery. However, commercially available access de...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Qi-long, Chen, Ke, Huang, Di-yu, Pan, Yu, Yan, Jia-fei, Wang, Xian-fa, Cai, Xiao-yan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7447498/
https://www.ncbi.nlm.nih.gov/pubmed/32846810
http://dx.doi.org/10.1097/MD.0000000000021787
_version_ 1783574314883219456
author Chen, Qi-long
Chen, Ke
Huang, Di-yu
Pan, Yu
Yan, Jia-fei
Wang, Xian-fa
Cai, Xiao-yan
author_facet Chen, Qi-long
Chen, Ke
Huang, Di-yu
Pan, Yu
Yan, Jia-fei
Wang, Xian-fa
Cai, Xiao-yan
author_sort Chen, Qi-long
collection PubMed
description Laparoscopic inguinal herniorrhaphy has been well established for the management of primary and recurrent inguinal hernias. Single-incision laparoscopic surgery (SILS) has now been accepted as a less invasive alternative to conventional laparoscopic surgery. However, commercially available access devices for SILS had disadvantages such as rigidness and crowding. This series aimed to analyze the feasibility and safety of single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty (SILS-TAPP) by applying our self-made device for managing inguinal hernia. We collected and reviewed the medical records of patients who received SILS-TAPP using a self-made glove-port device between January 2014 and January 2016. All operations were performed by the same surgical team. The demographics and intra- and perioperative outcomes were evaluated. SILS-TAPP was successfully performed in 105 patients (131 inguinal hernia repairs). No major intra- and postoperative morbidities were encountered, and no conversion to a conventional 3-port approach or open surgery was required. The mean operative time was 73.5 min and the mean postoperative hospital stay was 2.1 days. Three minor short-term complications were noted, which were resolved without surgical intervention. One recurrence was diagnosed during follow-up and treated using a second TAPP procedure. SILS-TAPP was shown to be a feasible, safe procedure in patients with an inguinal hernia. A simple self-made glove-port device was proven as a practical method of SILS-TAPP.
format Online
Article
Text
id pubmed-7447498
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-74474982020-09-04 Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port Chen, Qi-long Chen, Ke Huang, Di-yu Pan, Yu Yan, Jia-fei Wang, Xian-fa Cai, Xiao-yan Medicine (Baltimore) 7100 Laparoscopic inguinal herniorrhaphy has been well established for the management of primary and recurrent inguinal hernias. Single-incision laparoscopic surgery (SILS) has now been accepted as a less invasive alternative to conventional laparoscopic surgery. However, commercially available access devices for SILS had disadvantages such as rigidness and crowding. This series aimed to analyze the feasibility and safety of single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty (SILS-TAPP) by applying our self-made device for managing inguinal hernia. We collected and reviewed the medical records of patients who received SILS-TAPP using a self-made glove-port device between January 2014 and January 2016. All operations were performed by the same surgical team. The demographics and intra- and perioperative outcomes were evaluated. SILS-TAPP was successfully performed in 105 patients (131 inguinal hernia repairs). No major intra- and postoperative morbidities were encountered, and no conversion to a conventional 3-port approach or open surgery was required. The mean operative time was 73.5 min and the mean postoperative hospital stay was 2.1 days. Three minor short-term complications were noted, which were resolved without surgical intervention. One recurrence was diagnosed during follow-up and treated using a second TAPP procedure. SILS-TAPP was shown to be a feasible, safe procedure in patients with an inguinal hernia. A simple self-made glove-port device was proven as a practical method of SILS-TAPP. Lippincott Williams & Wilkins 2020-08-21 /pmc/articles/PMC7447498/ /pubmed/32846810 http://dx.doi.org/10.1097/MD.0000000000021787 Text en Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 7100
Chen, Qi-long
Chen, Ke
Huang, Di-yu
Pan, Yu
Yan, Jia-fei
Wang, Xian-fa
Cai, Xiao-yan
Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title_full Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title_fullStr Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title_full_unstemmed Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title_short Trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
title_sort trans-umbilical single-incision laparoscopic trans-abdominal pre-peritoneal hernioplasty of inguinal hernia by self-made glove port
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7447498/
https://www.ncbi.nlm.nih.gov/pubmed/32846810
http://dx.doi.org/10.1097/MD.0000000000021787
work_keys_str_mv AT chenqilong transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT chenke transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT huangdiyu transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT panyu transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT yanjiafei transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT wangxianfa transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport
AT caixiaoyan transumbilicalsingleincisionlaparoscopictransabdominalpreperitonealhernioplastyofinguinalherniabyselfmadegloveport