Cargando…
Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first identified in December 2019 and has quickly become a worldwide pandemic. In response, many diagnostic manufacturers have developed molecular assays for SARS-CoV-2 under the Food and Drug Administration (FDA) Emergency Use Authori...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7448672/ https://www.ncbi.nlm.nih.gov/pubmed/32571894 http://dx.doi.org/10.1128/JCM.01134-20 |
_version_ | 1783574526986027008 |
---|---|
author | Smith, Elizabeth Zhen, Wei Manji, Ryhana Schron, Deborah Duong, Scott Berry, Gregory J. |
author_facet | Smith, Elizabeth Zhen, Wei Manji, Ryhana Schron, Deborah Duong, Scott Berry, Gregory J. |
author_sort | Smith, Elizabeth |
collection | PubMed |
description | Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first identified in December 2019 and has quickly become a worldwide pandemic. In response, many diagnostic manufacturers have developed molecular assays for SARS-CoV-2 under the Food and Drug Administration (FDA) Emergency Use Authorization (EUA) pathway. This study compared three of these assays, the Hologic Panther Fusion SARS-CoV-2 assay (Fusion), the Hologic Aptima SARS-CoV-2 assay (Aptima), and the BioFire Defense COVID-19 test (BioFire), to determine analytical and clinical performance as well as workflow. All three assays showed similar limits of detection (LODs) using inactivated virus, with 100% detection, ranging from 500 to 1,000 genome equivalents/ml, whereas use of a quantified RNA transcript standard showed the same trend but had values ranging from 62.5 to 125 copies/ml, confirming variability in absolute quantification of reference standards. The clinical correlation found that the Fusion and BioFire assays had a positive percent agreement (PPA) of 98.7%, followed by the Aptima assay at 94.7%, compared to the consensus result. All three assays exhibited 100% negative percent agreement (NPA). Analysis of discordant results revealed that all four samples missed by the Aptima assay had cycle threshold (C(t)) values of >37 by the Fusion assay. In conclusion, while all three assays showed similar relative LODs, we showed differences in absolute LODs depending on which standard was employed. In addition, the Fusion and BioFire assays showed better clinical performance, while the Aptima assay showed a modest decrease in overall PPA. These findings should be kept in mind when making platform testing decisions. |
format | Online Article Text |
id | pubmed-7448672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | American Society for Microbiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-74486722020-09-09 Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection Smith, Elizabeth Zhen, Wei Manji, Ryhana Schron, Deborah Duong, Scott Berry, Gregory J. J Clin Microbiol Virology Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first identified in December 2019 and has quickly become a worldwide pandemic. In response, many diagnostic manufacturers have developed molecular assays for SARS-CoV-2 under the Food and Drug Administration (FDA) Emergency Use Authorization (EUA) pathway. This study compared three of these assays, the Hologic Panther Fusion SARS-CoV-2 assay (Fusion), the Hologic Aptima SARS-CoV-2 assay (Aptima), and the BioFire Defense COVID-19 test (BioFire), to determine analytical and clinical performance as well as workflow. All three assays showed similar limits of detection (LODs) using inactivated virus, with 100% detection, ranging from 500 to 1,000 genome equivalents/ml, whereas use of a quantified RNA transcript standard showed the same trend but had values ranging from 62.5 to 125 copies/ml, confirming variability in absolute quantification of reference standards. The clinical correlation found that the Fusion and BioFire assays had a positive percent agreement (PPA) of 98.7%, followed by the Aptima assay at 94.7%, compared to the consensus result. All three assays exhibited 100% negative percent agreement (NPA). Analysis of discordant results revealed that all four samples missed by the Aptima assay had cycle threshold (C(t)) values of >37 by the Fusion assay. In conclusion, while all three assays showed similar relative LODs, we showed differences in absolute LODs depending on which standard was employed. In addition, the Fusion and BioFire assays showed better clinical performance, while the Aptima assay showed a modest decrease in overall PPA. These findings should be kept in mind when making platform testing decisions. American Society for Microbiology 2020-08-24 /pmc/articles/PMC7448672/ /pubmed/32571894 http://dx.doi.org/10.1128/JCM.01134-20 Text en Copyright © 2020 American Society for Microbiology. All Rights Reserved (https://doi.org/10.1128/ASMCopyrightv2) . https://doi.org/10.1128/ASMCopyrightv2 This article is made available via the PMC Open Access Subset for unrestricted noncommercial re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Virology Smith, Elizabeth Zhen, Wei Manji, Ryhana Schron, Deborah Duong, Scott Berry, Gregory J. Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title | Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title_full | Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title_fullStr | Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title_full_unstemmed | Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title_short | Analytical and Clinical Comparison of Three Nucleic Acid Amplification Tests for SARS-CoV-2 Detection |
title_sort | analytical and clinical comparison of three nucleic acid amplification tests for sars-cov-2 detection |
topic | Virology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7448672/ https://www.ncbi.nlm.nih.gov/pubmed/32571894 http://dx.doi.org/10.1128/JCM.01134-20 |
work_keys_str_mv | AT smithelizabeth analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection AT zhenwei analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection AT manjiryhana analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection AT schrondeborah analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection AT duongscott analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection AT berrygregoryj analyticalandclinicalcomparisonofthreenucleicacidamplificationtestsforsarscov2detection |