Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures

BACKGROUND: The dynamic hip screw (DHS) with the addition of an angular stable trochanter-stabilizing plate (TSP) has been considered the ideal treatment for the unstable intertrochanteric fracture type. However, there have been few comparisons between DHS+TSP augmentation with intramedullary (IM) n...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Chun-Wei, Chen, Ji-Ying, Liu, Yueh-Ching, Liao, Kuang-Wen, Lu, Yung-Chang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7453265/
https://www.ncbi.nlm.nih.gov/pubmed/32923477
http://dx.doi.org/10.1155/2020/1896935
_version_ 1783575325863575552
author Fu, Chun-Wei
Chen, Ji-Ying
Liu, Yueh-Ching
Liao, Kuang-Wen
Lu, Yung-Chang
author_facet Fu, Chun-Wei
Chen, Ji-Ying
Liu, Yueh-Ching
Liao, Kuang-Wen
Lu, Yung-Chang
author_sort Fu, Chun-Wei
collection PubMed
description BACKGROUND: The dynamic hip screw (DHS) with the addition of an angular stable trochanter-stabilizing plate (TSP) has been considered the ideal treatment for the unstable intertrochanteric fracture type. However, there have been few comparisons between DHS+TSP augmentation with intramedullary (IM) nailing. The aim of this retrospectively registered study was to compare the clinical outcomes of patients with the unstable type of intertrochanteric fractures treated with DHS+TSP or IM nailing (proximal femoral nail antirotation (PFNA)). METHODS: From June 2013 to April 2018, 358 patients with proximal femur fracture AO/OTA type 31A2 and 31A3 treated with PFNA or DHS+TSP and followed for ≥10 months postoperatively were included. The surgical-dependent outcome evaluation included the operation time, intraoperative blood loss, postoperative decrease in hemoglobin, and blood transfusion amount. Functional status was also measured. Radiographic findings and postoperative complications were recorded and analyzed. RESULT: The operation time was significantly shorter in the DHS+TSP group than that in the PFNA group for both A2 and A3 fractures (A2 type: 84.0 vs.96.4 min; p < 0.05; A3 type: 102.4 vs.116.1 min; p < 0.05). Postoperative decrease in hemoglobin was more significant in the PFNA group than that in the DHS+TSP group for both fracture types (A2 type: −1.88 vs. −1.29 (mg/dL); p < 0.05; A3 type: −1.63 vs. −1.04 (mg/dL); p < 0.05). However, the patients treated with DHS+TSP had significantly more residual pain than those treated with PFNA during the final follow-up (Visual Analog Scale score, A2 type: 28.4 vs.23.2; p < 0.05; A3 type: 27.5 vs.23.6; p < 0.05) and complained of greater implant irritation. CONCLUSION: We found that DHS+TSP was associated with less operation time and less postoperative decrease in hemoglobin but more residual pain and implant irritation than those of PFNA. As a treatment for unstable intertrochanteric fracture, DHS+TSP provided ideal surgical outcomes which were not inferior to the PFNA.
format Online
Article
Text
id pubmed-7453265
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-74532652020-09-11 Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures Fu, Chun-Wei Chen, Ji-Ying Liu, Yueh-Ching Liao, Kuang-Wen Lu, Yung-Chang Biomed Res Int Research Article BACKGROUND: The dynamic hip screw (DHS) with the addition of an angular stable trochanter-stabilizing plate (TSP) has been considered the ideal treatment for the unstable intertrochanteric fracture type. However, there have been few comparisons between DHS+TSP augmentation with intramedullary (IM) nailing. The aim of this retrospectively registered study was to compare the clinical outcomes of patients with the unstable type of intertrochanteric fractures treated with DHS+TSP or IM nailing (proximal femoral nail antirotation (PFNA)). METHODS: From June 2013 to April 2018, 358 patients with proximal femur fracture AO/OTA type 31A2 and 31A3 treated with PFNA or DHS+TSP and followed for ≥10 months postoperatively were included. The surgical-dependent outcome evaluation included the operation time, intraoperative blood loss, postoperative decrease in hemoglobin, and blood transfusion amount. Functional status was also measured. Radiographic findings and postoperative complications were recorded and analyzed. RESULT: The operation time was significantly shorter in the DHS+TSP group than that in the PFNA group for both A2 and A3 fractures (A2 type: 84.0 vs.96.4 min; p < 0.05; A3 type: 102.4 vs.116.1 min; p < 0.05). Postoperative decrease in hemoglobin was more significant in the PFNA group than that in the DHS+TSP group for both fracture types (A2 type: −1.88 vs. −1.29 (mg/dL); p < 0.05; A3 type: −1.63 vs. −1.04 (mg/dL); p < 0.05). However, the patients treated with DHS+TSP had significantly more residual pain than those treated with PFNA during the final follow-up (Visual Analog Scale score, A2 type: 28.4 vs.23.2; p < 0.05; A3 type: 27.5 vs.23.6; p < 0.05) and complained of greater implant irritation. CONCLUSION: We found that DHS+TSP was associated with less operation time and less postoperative decrease in hemoglobin but more residual pain and implant irritation than those of PFNA. As a treatment for unstable intertrochanteric fracture, DHS+TSP provided ideal surgical outcomes which were not inferior to the PFNA. Hindawi 2020-08-18 /pmc/articles/PMC7453265/ /pubmed/32923477 http://dx.doi.org/10.1155/2020/1896935 Text en Copyright © 2020 Chun-Wei Fu et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Fu, Chun-Wei
Chen, Ji-Ying
Liu, Yueh-Ching
Liao, Kuang-Wen
Lu, Yung-Chang
Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title_full Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title_fullStr Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title_full_unstemmed Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title_short Dynamic Hip Screw with Trochanter-Stabilizing Plate Compared with Proximal Femoral Nail Antirotation as a Treatment for Unstable AO/OTA 31-A2 and 31-A3 Intertrochanteric Fractures
title_sort dynamic hip screw with trochanter-stabilizing plate compared with proximal femoral nail antirotation as a treatment for unstable ao/ota 31-a2 and 31-a3 intertrochanteric fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7453265/
https://www.ncbi.nlm.nih.gov/pubmed/32923477
http://dx.doi.org/10.1155/2020/1896935
work_keys_str_mv AT fuchunwei dynamichipscrewwithtrochanterstabilizingplatecomparedwithproximalfemoralnailantirotationasatreatmentforunstableaoota31a2and31a3intertrochantericfractures
AT chenjiying dynamichipscrewwithtrochanterstabilizingplatecomparedwithproximalfemoralnailantirotationasatreatmentforunstableaoota31a2and31a3intertrochantericfractures
AT liuyuehching dynamichipscrewwithtrochanterstabilizingplatecomparedwithproximalfemoralnailantirotationasatreatmentforunstableaoota31a2and31a3intertrochantericfractures
AT liaokuangwen dynamichipscrewwithtrochanterstabilizingplatecomparedwithproximalfemoralnailantirotationasatreatmentforunstableaoota31a2and31a3intertrochantericfractures
AT luyungchang dynamichipscrewwithtrochanterstabilizingplatecomparedwithproximalfemoralnailantirotationasatreatmentforunstableaoota31a2and31a3intertrochantericfractures