Cargando…
Highly sensitive and specific diagnosis of COVID-19 by reverse transcription multiple cross-displacement amplification-labelled nanoparticles biosensor
BACKGROUND: The ongoing outbreak of the novel human coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (also known as 2019-nCoV) has become a global health concern. Rapid and easy-to-use diagnostic techniques are urgently needed to diagnose SARS-CoV-2 infection. METHODS: We dev...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
European Respiratory Society
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7453731/ https://www.ncbi.nlm.nih.gov/pubmed/32859676 http://dx.doi.org/10.1183/13993003.02060-2020 |
Sumario: | BACKGROUND: The ongoing outbreak of the novel human coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (also known as 2019-nCoV) has become a global health concern. Rapid and easy-to-use diagnostic techniques are urgently needed to diagnose SARS-CoV-2 infection. METHODS: We devised a reverse transcription multiple cross-displacement amplification (RT-MCDA) coupled with a nanoparticle-based biosensor assay (RT-MCDA-BS) for rapid, sensitive and specific diagnosis of coronavirus disease 2019 (COVID-19). Two primer sets were designed to target the open reading frame 1a/b and nucleoprotein gene of SARS-CoV-2. A total of 183 clinical samples, including 65 patients with COVID-19 infection and 118 patients with other pathogen infections were used to testify the assay's feasibility. Diagnosis results were reported visually using the biosensor. FINDINGS: The assay designed was performed using a simple instrument which could maintain the reaction in a constant temperature at 64°C for only 35 min. The total COVID-19 RT-MCDA-BS test procedure could be finished within 1 h. The COVID-19 RT-MCDA-BS could detect down to five copies of target sequences. Among 65 clinical samples from the COVID-19 patients, 22 (33.8%) positive results were obtained from faeces, nasal, pharyngeal and anal swabs via COVID-19 RT-MCDA-BS assay, while real-time reverse transcription-PCR assay only detected 20 (30.7%) positive results in these samples. No positive results were obtained from clinical samples with non-COVID-19 infections. INTERPRETATION: COVID-19 RT-MCDA-BS was a rapid, reliable, low-cost and easy-to-use assay, which could provide an attractive laboratory tool to diagnose COVID-19 in multiple clinical specimens, especially for field, clinic laboratories and primary care facilities in resource-poor settings. |
---|