Cargando…

Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans

OBJECTIVE: To assess whether the computed tomography (CT)‐based method of three‐dimensional (3D) analysis (Mimics) was accurate and reliable for spine surgical anatomical measurements. METHODS: A total of 40 lumbar segments and 32 inter‐vertebral discs from eigth adult male cadavers without fracture...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Jie, Dong, Bo, Sun, Ju, Liu, Jian‐tao, Liu, Fang, Li, Xiao‐wei, Yuan, Pu‐wei, Zhang, Jian‐bao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7454159/
https://www.ncbi.nlm.nih.gov/pubmed/32618427
http://dx.doi.org/10.1111/os.12729
_version_ 1783575473866932224
author Yao, Jie
Dong, Bo
Sun, Ju
Liu, Jian‐tao
Liu, Fang
Li, Xiao‐wei
Yuan, Pu‐wei
Zhang, Jian‐bao
author_facet Yao, Jie
Dong, Bo
Sun, Ju
Liu, Jian‐tao
Liu, Fang
Li, Xiao‐wei
Yuan, Pu‐wei
Zhang, Jian‐bao
author_sort Yao, Jie
collection PubMed
description OBJECTIVE: To assess whether the computed tomography (CT)‐based method of three‐dimensional (3D) analysis (Mimics) was accurate and reliable for spine surgical anatomical measurements. METHODS: A total of 40 lumbar segments and 32 inter‐vertebral discs from eigth adult male cadavers without fractures or deformities fixed with the classical formaldehyde method were included in this research on 5 June 2017. CT scans including seven dimensions: anterior height of the vertebral body (VBHa), middle height of the vertebral body (VBHm), posterior height of the vertebral body (VBHp), width of the upper endplate (EPWu), depth of the upper endplate (EPDu), anterior height of the inter‐vertebral disc in the median sagittal plane (IDHa), and posterior height of the inter‐vertebral disc in the median sagittal plane (IDHp). They were performed based on uniform conditions (slice thickness: 0.625 mm) using a CT scanner on 8 June 2017. Afterwards, the surgical anatomical measurements were conducted with a Vernier caliper on 12 June 2017. The computer‐aided anatomical measurements were conducted by three investigators using Mimics 16.0 to perform 3D reconstructions of CT bone on 16 June 2017. Finally, the length and angle were measured with associated measurement tools, yielding a verified accuracy of 0.01 mm and 0.01°, respectively. Each measurement was repeated three times, and all anatomical data was analyzed using the statistical software and P‐value < 0.05 was considered statistically significant. RESULTS: The results showed no statistically significant difference was observed between the surgical anatomical and computer‐aided anatomical measurements (P > 0.05) for lumbar vertebra measurements, and the absolute difference between surgical and computer‐aided data were all less than 1.0 mm (for the VBHa, VBHm, VBHp, EPWu, and EPDu were 0.12, 0.03, 0.03, 0.31, and 0.03 mm, respectively). Moreover, although the absolute differences of discs was larger than those of lumbar vertebras, no significant differences were detected between the computer‐aided and surgical anatomical measurements for the IDHa, as well as IDHp in the vast majority of measurements (P = 0.543, 0.079 or 0.052 for IDHa, and P = 0.212, 0.133 or 0.042 for IDHp). In addition, excellent reliability correlation was observed between the measurements of each investigator, and the reliability coefficients in the intra‐groups were all greater than 0.9 except for IDHp (reliability coefficient = 0.892). Additionally, the reliability coefficients were greater than 0.9 for the all between‐group correlations, and a significant correlation was also observed. Furthermore, no statistically significant difference for three anatomical values was found in the computer‐assisted measurements of the lumbar bone structure (P > 0.05). Similarly, we did not observe a statistical difference in the anatomical data of the lumbar discs from the three measures (P > 0.05). CONCLUSIONS: Computer‐aided anatomical measurement for spine based on CT scans presents the high accuracy and reliability for improving spinal surgical procedures.
format Online
Article
Text
id pubmed-7454159
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-74541592020-09-02 Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans Yao, Jie Dong, Bo Sun, Ju Liu, Jian‐tao Liu, Fang Li, Xiao‐wei Yuan, Pu‐wei Zhang, Jian‐bao Orthop Surg Clinical Articles OBJECTIVE: To assess whether the computed tomography (CT)‐based method of three‐dimensional (3D) analysis (Mimics) was accurate and reliable for spine surgical anatomical measurements. METHODS: A total of 40 lumbar segments and 32 inter‐vertebral discs from eigth adult male cadavers without fractures or deformities fixed with the classical formaldehyde method were included in this research on 5 June 2017. CT scans including seven dimensions: anterior height of the vertebral body (VBHa), middle height of the vertebral body (VBHm), posterior height of the vertebral body (VBHp), width of the upper endplate (EPWu), depth of the upper endplate (EPDu), anterior height of the inter‐vertebral disc in the median sagittal plane (IDHa), and posterior height of the inter‐vertebral disc in the median sagittal plane (IDHp). They were performed based on uniform conditions (slice thickness: 0.625 mm) using a CT scanner on 8 June 2017. Afterwards, the surgical anatomical measurements were conducted with a Vernier caliper on 12 June 2017. The computer‐aided anatomical measurements were conducted by three investigators using Mimics 16.0 to perform 3D reconstructions of CT bone on 16 June 2017. Finally, the length and angle were measured with associated measurement tools, yielding a verified accuracy of 0.01 mm and 0.01°, respectively. Each measurement was repeated three times, and all anatomical data was analyzed using the statistical software and P‐value < 0.05 was considered statistically significant. RESULTS: The results showed no statistically significant difference was observed between the surgical anatomical and computer‐aided anatomical measurements (P > 0.05) for lumbar vertebra measurements, and the absolute difference between surgical and computer‐aided data were all less than 1.0 mm (for the VBHa, VBHm, VBHp, EPWu, and EPDu were 0.12, 0.03, 0.03, 0.31, and 0.03 mm, respectively). Moreover, although the absolute differences of discs was larger than those of lumbar vertebras, no significant differences were detected between the computer‐aided and surgical anatomical measurements for the IDHa, as well as IDHp in the vast majority of measurements (P = 0.543, 0.079 or 0.052 for IDHa, and P = 0.212, 0.133 or 0.042 for IDHp). In addition, excellent reliability correlation was observed between the measurements of each investigator, and the reliability coefficients in the intra‐groups were all greater than 0.9 except for IDHp (reliability coefficient = 0.892). Additionally, the reliability coefficients were greater than 0.9 for the all between‐group correlations, and a significant correlation was also observed. Furthermore, no statistically significant difference for three anatomical values was found in the computer‐assisted measurements of the lumbar bone structure (P > 0.05). Similarly, we did not observe a statistical difference in the anatomical data of the lumbar discs from the three measures (P > 0.05). CONCLUSIONS: Computer‐aided anatomical measurement for spine based on CT scans presents the high accuracy and reliability for improving spinal surgical procedures. John Wiley & Sons Australia, Ltd 2020-07-03 /pmc/articles/PMC7454159/ /pubmed/32618427 http://dx.doi.org/10.1111/os.12729 Text en © 2020 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Clinical Articles
Yao, Jie
Dong, Bo
Sun, Ju
Liu, Jian‐tao
Liu, Fang
Li, Xiao‐wei
Yuan, Pu‐wei
Zhang, Jian‐bao
Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title_full Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title_fullStr Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title_full_unstemmed Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title_short Accuracy and Reliability of Computer‐aided Anatomical Measurements for Vertebral Body and Disc Based on Computed Tomography Scans
title_sort accuracy and reliability of computer‐aided anatomical measurements for vertebral body and disc based on computed tomography scans
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7454159/
https://www.ncbi.nlm.nih.gov/pubmed/32618427
http://dx.doi.org/10.1111/os.12729
work_keys_str_mv AT yaojie accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT dongbo accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT sunju accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT liujiantao accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT liufang accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT lixiaowei accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT yuanpuwei accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans
AT zhangjianbao accuracyandreliabilityofcomputeraidedanatomicalmeasurementsforvertebralbodyanddiscbasedoncomputedtomographyscans