Cargando…

Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis

BACKGROUND: Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. OBJECTIVES: This...

Descripción completa

Detalles Bibliográficos
Autores principales: Rödel, Jürgen, Egerer, Renate, Suleyman, Aynur, Sommer-Schmid, Beatrice, Baier, Michael, Henke, Andreas, Edel, Birgit, Löffler, Bettina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7457909/
https://www.ncbi.nlm.nih.gov/pubmed/32891938
http://dx.doi.org/10.1016/j.jcv.2020.104616
_version_ 1783576092865462272
author Rödel, Jürgen
Egerer, Renate
Suleyman, Aynur
Sommer-Schmid, Beatrice
Baier, Michael
Henke, Andreas
Edel, Birgit
Löffler, Bettina
author_facet Rödel, Jürgen
Egerer, Renate
Suleyman, Aynur
Sommer-Schmid, Beatrice
Baier, Michael
Henke, Andreas
Edel, Birgit
Löffler, Bettina
author_sort Rödel, Jürgen
collection PubMed
description BACKGROUND: Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. OBJECTIVES: This study was designed to evaluate the clinical performance of the CE-labeled variplexTM real time SARS-CoV-2 RT-LAMP assay in comparison to commercial RT-PCRs. STUDY DESIGN: RNA extracted from pharyngeal swabs was tested by variplex™ RT-LAMP and Corman’s LightMix™ E gene RT-PCR as reference. Samples of respiratory secretions from Coronavirus infection disease (COVID-19) and negative control patients were analyzed by variplex™ without RNA extraction and tested in parallel with the Allplex™ and VIASURE BD MAX RT-PCRs. RESULTS: Using isolated RNA variplex™ RT-LAMP showed a sensitivity of 75 % compared to LightMix E gene RT-PCR but contrary to the latter it produced no false-positive results. For the evaluation of samples from respiratory secretions concordance analysis showed only a moderate agreement between the variplex™ RT-LAMP conducted on unprocessed samples and Allplex™ and VIASURE RT-PCRs (Cohen’s κ ranging from 0.52−0.56). Using the approach to define a sample as true-positive when at least two assays gave a positive result the clinical sensitivities were as follows: 76.3 % for variplex™, 84.2 % for Allplex™ and 68.4 % for VIASURE. However, when results of RT-PCR and RT-LAMP were combined diagnostic sensitivity was increased to 92–100 %. CONCLUSION: The variplex RT-LAMP may serve as a rapid test to be combined with a RT-PCR assay to increase the diagnostic accuracy in patients with suspected COVID-19 infection.
format Online
Article
Text
id pubmed-7457909
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-74579092020-09-01 Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis Rödel, Jürgen Egerer, Renate Suleyman, Aynur Sommer-Schmid, Beatrice Baier, Michael Henke, Andreas Edel, Birgit Löffler, Bettina J Clin Virol Article BACKGROUND: Molecular assays based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) may be useful for rapid diagnosis of the severe acute respiratory syndrome Coronavirus-2 (SARS-CoV-2) because of the easy performance and the option to bypass RNA extraction. OBJECTIVES: This study was designed to evaluate the clinical performance of the CE-labeled variplexTM real time SARS-CoV-2 RT-LAMP assay in comparison to commercial RT-PCRs. STUDY DESIGN: RNA extracted from pharyngeal swabs was tested by variplex™ RT-LAMP and Corman’s LightMix™ E gene RT-PCR as reference. Samples of respiratory secretions from Coronavirus infection disease (COVID-19) and negative control patients were analyzed by variplex™ without RNA extraction and tested in parallel with the Allplex™ and VIASURE BD MAX RT-PCRs. RESULTS: Using isolated RNA variplex™ RT-LAMP showed a sensitivity of 75 % compared to LightMix E gene RT-PCR but contrary to the latter it produced no false-positive results. For the evaluation of samples from respiratory secretions concordance analysis showed only a moderate agreement between the variplex™ RT-LAMP conducted on unprocessed samples and Allplex™ and VIASURE RT-PCRs (Cohen’s κ ranging from 0.52−0.56). Using the approach to define a sample as true-positive when at least two assays gave a positive result the clinical sensitivities were as follows: 76.3 % for variplex™, 84.2 % for Allplex™ and 68.4 % for VIASURE. However, when results of RT-PCR and RT-LAMP were combined diagnostic sensitivity was increased to 92–100 %. CONCLUSION: The variplex RT-LAMP may serve as a rapid test to be combined with a RT-PCR assay to increase the diagnostic accuracy in patients with suspected COVID-19 infection. Elsevier B.V. 2020-11 2020-08-31 /pmc/articles/PMC7457909/ /pubmed/32891938 http://dx.doi.org/10.1016/j.jcv.2020.104616 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Rödel, Jürgen
Egerer, Renate
Suleyman, Aynur
Sommer-Schmid, Beatrice
Baier, Michael
Henke, Andreas
Edel, Birgit
Löffler, Bettina
Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title_full Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title_fullStr Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title_full_unstemmed Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title_short Use of the variplex™ SARS-CoV-2 RT-LAMP as a rapid molecular assay to complement RT-PCR for COVID-19 diagnosis
title_sort use of the variplex™ sars-cov-2 rt-lamp as a rapid molecular assay to complement rt-pcr for covid-19 diagnosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7457909/
https://www.ncbi.nlm.nih.gov/pubmed/32891938
http://dx.doi.org/10.1016/j.jcv.2020.104616
work_keys_str_mv AT rodeljurgen useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT egererrenate useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT suleymanaynur useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT sommerschmidbeatrice useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT baiermichael useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT henkeandreas useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT edelbirgit useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis
AT lofflerbettina useofthevariplexsarscov2rtlampasarapidmolecularassaytocomplementrtpcrforcovid19diagnosis