Cargando…

Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction

OBJECTIVE: To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. MATERIALS AND METHODS: We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age,...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Jung Hee, Park, Eun-Ah, Lee, Whal, Ahn, Chulkyun, Kim, Jong-Hyo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7458859/
https://www.ncbi.nlm.nih.gov/pubmed/32729262
http://dx.doi.org/10.3348/kjr.2020.0020
_version_ 1783576278700392448
author Hong, Jung Hee
Park, Eun-Ah
Lee, Whal
Ahn, Chulkyun
Kim, Jong-Hyo
author_facet Hong, Jung Hee
Park, Eun-Ah
Lee, Whal
Ahn, Chulkyun
Kim, Jong-Hyo
author_sort Hong, Jung Hee
collection PubMed
description OBJECTIVE: To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. MATERIALS AND METHODS: We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age, 67.0 ± 10.8 years) who had undergone both CCTA and invasive coronary artery angiography from March 2017 to June 2018. All included patients underwent CCTA with iterative reconstruction (ADMIRE level 3, Siemens Healthineers). We developed a deep learning based denoising technique (ClariCT.AI, ClariPI), which was based on a modified U-net type convolutional neural net model designed to predict the possible occurrence of low-dose noise in the originals. Denoised images were obtained by subtracting the predicted noise from the originals. Image noise, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively calculated. The edge rise distance (ERD) was measured as an indicator of image sharpness. Two blinded readers subjectively graded the image quality using a 5-point scale. Diagnostic performance of the CCTA was evaluated based on the presence or absence of significant stenosis (≥ 50% lumen reduction). RESULTS: Objective image qualities (original vs. denoised: image noise, 67.22 ± 25.74 vs. 52.64 ± 27.40; SNR [left main], 21.91 ± 6.38 vs. 30.35 ± 10.46; CNR [left main], 23.24 ± 6.52 vs. 31.93 ± 10.72; all p < 0.001) and subjective image quality (2.45 ± 0.62 vs. 3.65 ± 0.60, p < 0.001) improved significantly in the denoised images. The average ERDs of the denoised images were significantly smaller than those of originals (0.98 ± 0.08 vs. 0.09 ± 0.08, p < 0.001). With regard to diagnostic accuracy, no significant differences were observed among paired comparisons. CONCLUSION: Application of the deep learning technique along with iterative reconstruction can enhance the noise reduction performance with a significant improvement in objective and subjective image qualities of CCTA images.
format Online
Article
Text
id pubmed-7458859
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-74588592020-10-01 Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction Hong, Jung Hee Park, Eun-Ah Lee, Whal Ahn, Chulkyun Kim, Jong-Hyo Korean J Radiol Cardiovascular Imaging OBJECTIVE: To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. MATERIALS AND METHODS: We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age, 67.0 ± 10.8 years) who had undergone both CCTA and invasive coronary artery angiography from March 2017 to June 2018. All included patients underwent CCTA with iterative reconstruction (ADMIRE level 3, Siemens Healthineers). We developed a deep learning based denoising technique (ClariCT.AI, ClariPI), which was based on a modified U-net type convolutional neural net model designed to predict the possible occurrence of low-dose noise in the originals. Denoised images were obtained by subtracting the predicted noise from the originals. Image noise, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively calculated. The edge rise distance (ERD) was measured as an indicator of image sharpness. Two blinded readers subjectively graded the image quality using a 5-point scale. Diagnostic performance of the CCTA was evaluated based on the presence or absence of significant stenosis (≥ 50% lumen reduction). RESULTS: Objective image qualities (original vs. denoised: image noise, 67.22 ± 25.74 vs. 52.64 ± 27.40; SNR [left main], 21.91 ± 6.38 vs. 30.35 ± 10.46; CNR [left main], 23.24 ± 6.52 vs. 31.93 ± 10.72; all p < 0.001) and subjective image quality (2.45 ± 0.62 vs. 3.65 ± 0.60, p < 0.001) improved significantly in the denoised images. The average ERDs of the denoised images were significantly smaller than those of originals (0.98 ± 0.08 vs. 0.09 ± 0.08, p < 0.001). With regard to diagnostic accuracy, no significant differences were observed among paired comparisons. CONCLUSION: Application of the deep learning technique along with iterative reconstruction can enhance the noise reduction performance with a significant improvement in objective and subjective image qualities of CCTA images. The Korean Society of Radiology 2020-10 2020-07-17 /pmc/articles/PMC7458859/ /pubmed/32729262 http://dx.doi.org/10.3348/kjr.2020.0020 Text en Copyright © 2020 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Hong, Jung Hee
Park, Eun-Ah
Lee, Whal
Ahn, Chulkyun
Kim, Jong-Hyo
Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title_full Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title_fullStr Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title_full_unstemmed Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title_short Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
title_sort incremental image noise reduction in coronary ct angiography using a deep learning-based technique with iterative reconstruction
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7458859/
https://www.ncbi.nlm.nih.gov/pubmed/32729262
http://dx.doi.org/10.3348/kjr.2020.0020
work_keys_str_mv AT hongjunghee incrementalimagenoisereductionincoronaryctangiographyusingadeeplearningbasedtechniquewithiterativereconstruction
AT parkeunah incrementalimagenoisereductionincoronaryctangiographyusingadeeplearningbasedtechniquewithiterativereconstruction
AT leewhal incrementalimagenoisereductionincoronaryctangiographyusingadeeplearningbasedtechniquewithiterativereconstruction
AT ahnchulkyun incrementalimagenoisereductionincoronaryctangiographyusingadeeplearningbasedtechniquewithiterativereconstruction
AT kimjonghyo incrementalimagenoisereductionincoronaryctangiographyusingadeeplearningbasedtechniquewithiterativereconstruction